Eaton DPF222RGF15WTST Air Disconnect - UL Listed
Part Number: DPF222RGF15WTST
Quick Summary
Eaton DPF222RGF15WTST air conditioning disconnect provides safe power isolation for outdoor HVAC equipment. Facility managers struggle with weather exposure and tamper risks that trigger unexpected outages. CSA Certified and UL Listed, with a 10 kAIC interrupt rating, ensure robust protection in harsh environments. Its fused pullout design simplifies maintenance and replacement, while the NEMA 3R galvanized enclosure resists rain, dust, and corrosion for long service life. Designed for 120/240 V systems and compatible with #14-3 Cu/Al wiring, it supports efficient integration with existing electrical panels and HVAC control wiring.
Product Information
Extended Description
DPF222RGF15WTST Eaton: Eaton air conditioning disconnect, Fused pullout, 15A weather/tamper-resistant ground fault self-test receptacle, 60A, 120/240V, 10 kAIC, #14-3 Cu/Al 60°C or 75°C, NEMA 3R Galvanized Steel enclosure
Product Name
Eaton air conditioning disconnect
Catalog Number
DPF222RGF15WTST
UPC
786689014735
Product Length/Depth
7.5 in
Product Height
13 in
Product Width
4.75 in
Product Weight
8 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
CSA Certified UL Listed
Type
Fused pullout
Amperage Rating
60A
Horsepower
3 hp at 120 V, 10 hp at 240 V
Voltage rating
120/240 V
Wire size
#14-3 AWG Cu/Al
Color
ANSI 61 gray
Enclosure
NEMA 3R
Enclosure material
Galvanized steel
Interrupt rating
10 kAIC
Receptacle
15 A weather/tamper-resistant ground fault receptacle
Residential and Light Commercial, Air Conditioning Disconnects, Volume 1 Tab 6
Eaton Specification Sheet - DPF222RGF15WTST
Fused pullout design enables quick fuse replacement without exposing downstream circuitry to the elements. This reduces maintenance time and minimizes downtime during service windows, improving equipment availability. It is ideal for outdoor HVAC disconnects on rooftops and outdoor condensers, where weather exposure and tamper risks are highest. 60A amperage rating supports standard HVAC loads, with 3 hp at 120 V and 10 hp at 240 V. This helps prevent nuisance tripping while allowing efficient system startup and operation. It suits mid-size commercial rooftop units and outdoor condensers that require solid, code-compliant disconnects. 10 kAIC interrupt rating delivers high fault current protection, preserving downstream equipment. That translates to reduced risk of transformer and wiring damage during faults and easier compliance with utility requirements. This is particularly beneficial for outdoor installations where fault energy can be higher, such as near service entrances or in crowded mechanical rooms. 15 A weather/tamper-resistant ground fault receptacle ensures safe, code-compliant outlets for maintenance gear and test equipment. The safety feature reduces shock risk and supports code compliance for outdoor work. Use cases include servicing fans, sensors, and control devices without compromising enclosure integrity. Enclosure is NEMA 3R galvanized steel, providing rain, dust, and corrosion protection. This extends service life and minimizes weather-induced downtime for outdoor installations and industrial environments. Wire size compatibility with #14-3 Cu/Al simplifies wiring in field assemblies. Color and form factor help comply with color-coded systems, while the compact footprint supports panel integration and reduces mounting requirements.
Get a Quick Quote for a Eaton DPF222RGF15WTST
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton DPF222RGF15WTST?
Enquire Now
FAQs
Begin by ensuring power is de-energized and the disconnect is mounted in a suitable exterior-ready enclosure. Route conductors to the fused pullout according to the catalog specifications, matching #14-3 Cu/Al conductors to the terminal block. Tighten lugs to torque specifications, verify proper insulation and protection from the environment, and test the circuit upon re-energization to confirm correct operation.
The 10 kAIC interrupt rating indicates the maximum fault current the disconnect can safely interrupt without damage. This provides enhanced protection for downstream equipment, reduces the likelihood of cascading faults, and supports compliance with utility and design standards in outdoor and industrial installations.
Yes. The DPF222RGF15WTST is designed for outdoor use with a NEMA 3R galvanized steel enclosure, weather-resistant construction, and CSA UL certification. It supports 120/240 V HVAC loads and provides a rugged, tamper-resistant receptacle, making it a robust choice for rooftop units, condensers, and other outdoor cooling equipment.
The unit is CSA Certified and UL Listed, confirming conformity to recognized safety standards. These certifications help ensure reliable performance, ease of regulatory compliance for installation sites, and acceptance by electrical inspectors, contractors, and facility managers when integrating outdoor HVAC disconnects.
Expect reduced maintenance downtime due to the fused pullout design, quick fuse replacement, and a durable NEMA 3R enclosure protecting against weather. The combination lowers total cost of ownership by extending service intervals, minimizing unexpected outages, and delivering safer, code-compliant operation for mid-size commercial HVAC systems.