Eaton E2LEM36002W E2 mining MCCB - UL Listed
Part Number: E2LEM36002W
Quick Summary
Eaton E2LEM36002W is a mining MCCB protecting large underground mining drives and distribution. Operators face nuisance trips and limited protection coordination in harsh underground environments, which can lead to unscheduled downtime. UL Listed, IEC Rated, and CSA Certified certifications provide regulatory reassurance across mining sites, supporting safety and traceability. With electronic LSI trip and a robust L-frame design, installation teams gain reliable protection and easy integration with existing E2 mining MCCB systems. Its 600 A rating and 1000Y/577 Vac capability support scalable protection for medium- to high-current feeders, improving overall plant reliability.
Product Information
Extended Description
E2LEM36002W Eaton: Eaton E2 mining complete molded case circuit breaker, L-frame, E2LEM, Electr. LSI trip, 2500-5000A, Three-pole, 600A, 1000Y/577 Vac, 250 Vdc
Product Name
Eaton E2 mining complete molded case circuit breaker
Catalog Number
E2LEM36002W
UPC
782116035731
Product Length/Depth
7 in
Product Height
10 in
Product Width
13 in
Product Weight
20 lb
Certifications
UL Listed IEC Rated CSA Certified
Type
E2 mining
Amperage Rating
600 A
Voltage rating
1000Y/577 Vac, 250 Vdc
Trip Type
Electronic LSI
Circuit breaker type
E2LEM
Circuit breaker frame type
Complete breaker
Terminals
Without terminals
Frame
L
Class
Mining
Interrupt rating
35 kAIC at 480 Vac 10 kAIC at 1000Y/577 Vac 22 kAIC at 250 Vdc 65 kAIC at 240 Vac 25 kAIC at 600 Vac
Number of poles
Three-pole
Trip rating
2500-5000 A
Breaker service center locations product aid
Breaker service center locations product aid
Breaker service center locations product aid
Breaker service center locations product aid
Circuit Protection, Molded Case Circuit Breakers, Volume 4, Tab 2
MSHA policy letter for suitability, safety and performance of circuit breakers
Robinson Mine Case Study: Solutions for the mining industry
Digitrip 310+ vs. 310 electronic trip unit technical comparison
Digitrip 310+ vs. 310 electronic trip unit technical comparison
Digitrip 310+ vs. 310 electronic trip unit technical comparison
Digitrip 310+ vs. 310 electronic trip unit technical comparison
Understanding circuit breaker design and operation to improve safety and reliability in underground mining
Electronic LSI trip is designed for precise, selective protection, meaning feeders trip only when truly needed. This reduces nuisance trips, improves system availability, and minimizes wear on upstream gear in demanding mining environments. In practice, you gain fewer unplanned shutdowns while maintaining robust fault isolation for critical conveyors and distribution panels. Three-pole, L-frame E2LEM36002W delivers consistent performance across three-phase power, enabling straightforward busbar integration and synchronized protection across drum motors and drive systems. The 600 A amperage rating paired with 1000Y/577 Vac and 250 Vdc voltage ratings extends compatibility to mixed AC-DC mining loads, supporting safe, code-compliant motor starting and power distribution. With a 35 kAIC interrupt rating at 480 Vac and 10 kAIC at 1000Y/577 Vac, it handles high-energy faults while maintaining selectivity and fast clearance. The unit is CSA Certified, IEC Rated, and UL Listed, ensuring mining-grade safety and regulatory compliance. Installation remains straightforward due to its frame type (L) and product design that supports modular upgrades, backward compatibility with existing Digitrip 310+ electronic trip units, and integration with mining service centers for quick commissioning. This combination reduces total cost of ownership by simplifying spares logistics, enabling predictable maintenance, and supporting longer asset life for critical underground power systems. In addition, the absence of terminals on the unit encourages clean, space-efficient panel layouts and reduces terminal torque variability during field wiring, helping technicians achieve consistent, repeatable terminations in demanding environments. The E2LEM36002W is well-suited for mining feeders, crusher stations, and ventilation drives where high-current protection, robust fault handling, and reliable performance are essential for uptime and safety.
Get a Quick Quote for a Eaton E2LEM36002W
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton E2LEM36002W?
Enquire Now
FAQs
The E2LEM36002W uses an L-frame, three-pole design and is specified as 'Terminals: Without terminals,' meaning field wiring should be planned with external bus bars and terminations. This simplifies panel layout in compact mining enclosures and supports clean, repeatable electrical terminations in harsh underground environments.
This unit offers a 600 A amperage rating with a diverse interrupt capability: 35 kAIC at 480 Vac, 10 kAIC at 1000Y/577 Vac, and 22 kAIC at 250 Vdc, plus 65 kAIC at 240 Vac and 25 kAIC at 600 Vac. The trip type is electronic LSI, enabling selective protection and fast fault clearance for critical mining loads.
Yes. The three-pole, mining-class E2LEM device is rated for high current and harsh environments, with 1000Y/577 Vac and 600 A capabilities, making it well-suited for conveyor drives, crushers, and other heavy mining feeders while providing reliable fault protection and coordination with Digitrip 310+ trip units.
The device is UL Listed, IEC Rated, and CSA Certified, aligning with major mining and electrical safety standards. These certifications support regulatory compliance, safer operation in underground facilities, and easier procurement through established safety portfolios.
Take advantage of Eaton’s mining service centers and available documentation, including Digitrip 310+ comparisons and mining-specific case studies. Flexible spares, service tooling, and documented maintenance practices help maximize uptime, reduce warranty risk, and optimize life-cycle cost for high-current mining feeders.