Eaton E2LEM3600MW Molded Case Breaker - UL Listed Mining

Part Number: E2LEM3600MW
Manufacturer
Eaton
Part number
E2LEM3600MW

Quick Summary

The Eaton E2 mining complete molded case circuit breaker protects mining electrical systems from overloads and short circuits. Engineers and maintenance teams often wrestle with nuisance trips, mis-coordination, and downtime; this device delivers precise electronic LI protection and a robust three-pole, L-frame design that fits standard mining MCCB panels. UL Listed, IEC Rated, and CSA Certified, it meets essential mining and electrical safety standards while performing in harsh underground environments. With a 600 A rating and a wide voltage window of 1000Y/577 Vac and 250 Vdc, it supports scalable protection for large feeders and motor circuits, reducing maintenance costs, improving reliability, and speeding commissioning in mining operations.

Product Information

Extended Description

E2LEM3600MW Eaton: Eaton E2 mining complete molded case circuit breaker, L-frame, E2LEM, Complete breaker, Electronic LI trip, 500-2500A trip rating, Three-pole, 600A, 1000Y/577 Vac, 250 Vdc, Without terminals, Mining
Product Name
Eaton E2 mining complete molded case circuit breaker
Catalog Number
E2LEM3600MW
UPC
782114208830
Product Length/Depth
8.25 in
Product Height
8.25 in
Product Width
8.25 in
Product Weight
20 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed IEC Rated CSA Certified
Type
E2 mining
Amperage Rating
600 A
Voltage rating
1000Y/577 Vac, 250 Vdc
Trip Type
T165
Circuit breaker type
E2LEM
Circuit breaker frame type
Complete breaker
Magnetic trip range
500-2500A
Terminals
Without terminals
Frame
L
Class
Mining
Interrupt rating
25 kAIC at 600 Vac 10 kAIC at 1000Y/577 Vac 35 kAIC at 480 Vac 22 kAIC at 250 Vdc 65 kAIC at 240 Vac
Number of poles
Three-pole
Trip rating
500-2500 A
Three-pole, L-frame complete breaker design enables straightforward installation in existing mining panels, reducing commissioning time and enclosure depth. This simplifies wiring, minimizes gaps, and helps maintain consistent bus bar alignment in rugged mining installations. In real-world mine sites, quick field replacement lowers downtime and supports continuous production. Electronic LI trip provides fast, precise overcurrent protection with adjustable trip characteristics, decreasing nuisance trips while maintaining motor and feeder safety. This enables better protection coordination for underground mining motors, feeders, and conveyors with reduced maintenance interventions. The unit supports high interrupt ratings across multiple voltages—25 kAIC at 600 Vac, 10 kAIC at 1000Y/577 Vac, 35 kAIC at 480 Vac, 22 kAIC at 250 Vdc, and 65 kAIC at 240 Vac—allowing safe isolation in fault-heavy mining networks and protecting critical feeders and drives. Voltage ratings of 1000Y/577 Vac and 250 Vdc cover both three-phase distribution and DC control circuits common in mining equipment, while the absence of terminals offers flexibility for field wiring and lugs that match your panel design. The complete breaker architecture, along with a manageable 20 lb weight, simplifies installation in tight underground spaces and accelerates maintenance swaps. Certifications UL Listed, IEC Rated, and CSA Certified reinforce compliance with global mining safety standards, reducing risk during audits and site inspections. A one-year warranty from installation or 18 months from shipment provides a clear service window for performance verification and long-term reliability in demanding environments.

Get a Quick Quote for a Eaton E2LEM3600MW

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton E2LEM3600MW? Enquire Now

FAQs

The E2LEM3600MW uses a three-pole, L-frame complete breaker design intended for standard mining MCCB panels. It is compatible with common service centers and feeder enclosures that accept three-pole molded case breakers. Since terminals are not included, verify enclosure space and plan for appropriate terminations or lugs during the installation to ensure secure, code-compliant wiring.
Key specs include a 600 A amperage rating, voltage rating of 1000Y/577 Vac and 250 Vdc, trip type T165, and a three-pole E2LEM design. Interrupt ratings reach up to 25 kAIC at 600 Vac, 10 kAIC at 1000Y/577 Vac, 35 kAIC at 480 Vac, 22 kAIC at 250 Vdc, and 65 kAIC at 240 Vac, supporting robust fault current handling in mining networks.
Yes. The E2LEM3600MW is designed for mining environments, with mining-class construction, UL Listed, IEC Rated, and CSA Certified validation. Its electronic LI trip and rugged L-frame, three-pole configuration support reliable protection for underground feeders and motor circuits, helping minimize downtime and improve safety and compliance in underground mining installations.
The breaker is UL Listed, IEC Rated, and CSA Certified. These certifications validate electrical safety, performance under mining conditions, and regulatory compliance across North America and international markets. For procurement and audits, these marks help ensure compatibility with safety standards, reduce risk of noncompliant equipment, and streamline commissioning and maintenance in regulated mining operations.
The product carries Eaton’s standard warranty: one year from date of installation or eighteen months from shipment, whichever occurs first. This coverage supports early-life performance validation and provides a baseline for maintenance planning. For long-term reliability, pairing with Eaton service policies and up-to-date data sheets helps ensure continued protection and availability in critical mining applications.