Eaton E2LEM3600MWA05 Mining MCCB - UL Listed, 65 kAIC

Part Number: E2LEM3600MWA05
Manufacturer
Eaton
Part number
E2LEM3600MWA05

Quick Summary

Eaton E2LEM3600MWA05 mining MCCB provides overcurrent protection for mining equipment in underground and surface operations. It helps engineers avoid costly downtime from nuisance trips while simplifying critical safety compliance. Certified UL Listed, IEC Rated, and CSA Certified, the device meets mining industry standards and global codes. Designed for rugged electrical protection in mining, it supports easy installation on L-frame complete breakers and scales from 500 to 2500 A. With proven performance in harsh underground environments, it delivers reliable protection and business value.

Product Information

Extended Description

E2LEM3600MWA05 Eaton: Eaton E2 mining complete molded case circuit breaker, L-frame, E2LEM, Complete breaker, Electronic LI trip, 500-2500A trip rating, Three-pole, 600A, 1000Y/577 Vac, 250 Vdc, Without terminals, Mining, 1A-1B same side with right pigtail
Product Name
Eaton E2 mining complete molded case circuit breaker
Catalog Number
E2LEM3600MWA05
UPC
782114345351
Product Length/Depth
10.75 in
Product Height
8.25 in
Product Width
4.06 in
Product Weight
20 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
UL Listed IEC Rated CSA Certified
Type
E2 mining
Amperage Rating
600 A
Voltage rating
1000Y/577 Vac, 250 Vdc
Trip Type
T165
Circuit breaker type
E2LEM
Circuit breaker frame type
Complete breaker
Auxiliary switch
1A-1B same side with right pigtail
Magnetic trip range
500-2500A
Terminals
Without terminals
Frame
L
Class
Mining
Interrupt rating
65 kAIC at 240 Vac 35 kAIC at 480 Vac 25 kAIC at 600 Vac 10 kAIC at 1000Y/577 Vac 22 kAIC at 250 Vdc
Number of poles
Three-pole
Trip rating
500-2500 A
Feature: Electronic LI trip provides precise fault protection → Business Impact: reduces nuisance trips and enables selective tripping; Application: ideal for conveyors, motors, and feeder circuits in tough mining environments. Feature: 3-pole L-frame complete breaker rated 600 A with 1000Y/577 Vac and 250 Vdc → Business Impact: supports multi-volt, multi-system protection and simplifies panel design; Application: mining substations and distribution panels. Feature: 65 kAIC interrupt rating at 240 Vac (and other listed ratings) → Business Impact: handles high fault currents to minimize cascading outages; Application: heavy mining drives and critical motors. Feature: Without terminals → Business Impact: reduces field wiring complexity and installation time; Application: compact panel retrofits and retrofits in constrained underground spaces. Feature: Auxiliary switch 1A-1B on the same side with right pigtail → Business Impact: enables remote signaling and control integration; Application: control circuits and safety interlocks in mining equipment. Feature: Certifications UL Listed, IEC Rated, CSA Certified → Business Impact: supports regulatory compliance and QA processes; Application: procurement and safety audits across global mining sites.

Get a Quick Quote for a Eaton E2LEM3600MWA05

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton E2LEM3600MWA05? Enquire Now

FAQs

The E2LEM3600MWA05 is a three-pole, L-frame complete breaker designed for mining panels. It features a without terminals configuration and an auxiliary switch on the same side with a right pigtail, simplifying wiring. Ensure the panel supports an L-frame full-break unit, connect the bus and field wiring according to the latest Eaton installation instructions, torque specifications, and safety procedures to minimize downtime and maximize protection reliability.
Key ratings include a 600 A amperage rating, voltage support of 1000Y/577 Vac and 250 Vdc, and a T165 trip type. The device provides a magnetic trip range of 500-2500 A and interrupt ratings up to 65 kAIC at 240 Vac, with additional ratings at other voltages. This combination offers fast, selective fault clearing for three-phase mining propulsion and distribution systems.
Yes. It is explicitly designed for mining environments, featuring an L-frame complete breaker, three-pole configuration, and a rugged build to withstand underground conditions. Certifications UL Listed, IEC Rated, and CSA Certified support compliance with mine safety and international codes. Its high interrupt ratings and multi-voltage capability make it a robust choice for underground and surface mining installations.
This model carries UL Listed, IEC Rated, and CSA Certified credentials. These certifications indicate conformance to widely recognized safety and performance standards, simplifying procurement, compliance audits, and warranty support. For mining operations, such certifications help satisfy regulatory requirements and customer-driven QA processes across multiple regions.
The unit’s robust electronic trip and high interrupt ratings contribute to reduced unplanned downtime and improved equipment availability, delivering favorable total cost of ownership. A one-year warranty from installation or eighteen months from shipment provides protection during early use. Regular inspection of electrical connections and adherence to Eaton’s service guidelines will help sustain reliability in demanding mining environments.