Eaton E2LM3600W mining complete molded case circuit breaker protects mining electrical systems with rugged reliability. In challenging underground or surface mining environments, downtime and nuisance trips can derail production schedules. This MCCB features an interchangeable thermal-magnetic trip and a broad magnetic trip range of 3000–6000 A for adaptable protection, with strong interrupt ratings. Certifications and compliance data are provided by the manufacturer; verify current approvals such as CE, SIL, or IP ratings on the latest datasheet. For project engineers, the 600 A rating at 1000Y/577 Vac (and 250 Vdc) enables safe, compliant motor protection and fast field deployment in mining panels.

Product Information

Extended Description

E2LM3600W Eaton: Eaton E2 mining complete molded case circuit breaker, L-frame, E2LM, Complete breaker, Interchangeable thermal-magnetic trip, 3000-6000A trip rating, Three-pole, 600A, 1000Y/577 Vac, 250 Vdc, Without terminals, Mining
Product Name
Eaton E2 mining complete molded case circuit breaker
Catalog Number
E2LM3600W
UPC
782114208885
Product Length/Depth
4.06 in
Product Height
10.75 in
Product Width
8.25 in
Product Weight
20 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Certifications
Contact Manufacturer
Type
Specialty complete
Amperage Rating
600 A
Voltage rating
1000Y/577 Vac, 250 Vdc
Trip Type
T207
Circuit breaker type
E2LM
Circuit breaker frame type
Complete breaker
Magnetic trip range
3000-6000A
Terminals
Without terminals
Frame
L
Class
Mining
Interrupt rating
35 kAIC at 600 Vac 65 kAIC at 480 Vac 10 kAIC at 1000Y/577 Vac 42 kAIC at 250 Vdc 100 kAIC at 240 Vac
Number of poles
Three-pole
Trip rating
3000-6000 A
Feature: Interchangeable thermal-magnetic trip (T207) enables quick tailoring of protection to changing mining motor loads. Business Impact: Reduces spare parts and downtime while maintaining precise coordination with upstream protection. Application: Ideal for variable-load mining conveyors and pumps where protection settings must adapt over the life of the installation.\n\nFeature: Broad magnetic trip range of 3000–6000 A provides scalable short-circuit protection. Business Impact: Supports high-inertia motor starting and fault currents common in mining, reducing harmful fault energy. Application: Suitable for large-motor feeders in underground haulage systems.\n\nFeature: High interrupt ratings across multiple voltages (35 kAIC at 600 Vac, 65 kAIC at 480 Vac, 10 kAIC at 1000Y/577 Vac, 42 kAIC at 250 Vdc, 100 kAIC at 240 Vac). Business Impact: Enhances system safety margins and equipment longevity by delivering robust fault clearance. Application: Mining switchgear and service centers requiring dependable fault interruption.\n\nFeature: Three-pole L-frame complete breaker design with no terminals included. Business Impact: Simplifies integration with existing mining panels and reduces field wiring complexity. Application: Panel retrofits and new installations in rugged mining environments.\n\nFeature: Without terminals option supports flexible lug and bus-bar configurations. Business Impact: Enables rapid field wiring customization, reducing installation time and labor costs. Application: Custom mining control panels and remote feeder assemblies.\n\nFeature: Durable build for mining service with 600 A rating and 1000Y/577 Vac, 250 Vdc compatibility. Business Impact: Delivers reliable protection for high-demand mining drives while supporting mixed AC/DC systems. Application: Mining equipment protection in both surface and underground facilities.

Get a Quick Quote for a Eaton E2LM3600W

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton E2LM3600W? Enquire Now

FAQs

The E2LM3600W is a three-pole L-frame MCCB designed for mining service panels. It ships without terminals, enabling site-specific lug or bus-bar configurations. For installation, verify compatible bus structures, secure mounting in standard switchgear, and align with the intended 1000Y/577 Vac and 250 Vdc environments. Use Eaton accessories as recommended in the latest datasheet to ensure proper coordination with adjacent protection devices and service centers.
Key ratings include a 600 A amperage, 1000Y/577 Vac, 250 Vdc voltage profile, and a magnetic trip range of 3000–6000 A with an T207 trip type. Interrupt ratings vary by voltage: 35 kAIC at 600 Vac, 65 kAIC at 480 Vac, 10 kAIC at 1000Y/577 Vac, 42 kAIC at 250 Vdc, and 100 kAIC at 240 Vac. These figures support reliable fault clearing for high-energy mining applications and mixed AC/DC control circuits.
Yes, the E2LM3600W is designed for mining applications with a broad voltage tolerance (AC and DC) and a high interrupt capacity appropriate for large-motor feeders. Its three-pole E2LM design, together with an interchangeable thermal-magnetic trip, supports protection coordination for both underground and surface mining equipment, including DC control circuits when properly wired with compatible accessories.
Certification and compliance data are provided by Eaton. For current approvals such as CE, SIL, or IP ratings, consult the latest Eaton datasheet and MSHA-related guidance. Always verify the specific regulatory requirements for your mining site and regional standards before field deployment.
The E2LM3600W offers durable protection with a robust trip range and high interrupt ratings, reducing unplanned outages and maintenance complexity. Its interchangeable trip units simplify field service and reduce spare-part inventory. In mining operations, this translates to improved equipment uptime, shorter downtime during maintenance cycles, and predictable protection for motors and feeders in harsh environments.