Eaton E2LM3600WS02U42Z12 Complete MCCB - Mining L-frame

Part Number: E2LM3600WS02U42Z12
Manufacturer
Eaton
Part number
E2LM3600WS02U42Z12

Quick Summary

Eaton E2LM3600WS02U42Z12 is a mining complete molded case circuit breaker designed for rugged underground and surface electrical systems. Engineers often contend with nuisance trips, slow response, and misaligned protection in harsh mining environments. While exact compliance markings aren’t listed here, the manufacturer provides certifications and MSHA safety guidance via downloadable literature. This model emphasizes a mining-class, L-frame design with a 3-pole configuration, 600 A rating, and broad voltage capabilities, offering fast, reliable protection. The product also supports remote and local control options, delivering dependable protection inside mining control panels and MCCs while aligning with upgrade paths and accessory compatibility for long-term reliability.

Product Information

Extended Description

E2LM3600WS02U42Z12 Eaton: Eaton E2 mining complete molded case circuit breaker, L-frame, E2LM, Interchangeable thermal-magnetic trip, 3000-6000A trip rating, Three-pole, 600A, 1000Y/577 Vac, 250 Vdc, 12-24 Vac/dc same side w/left pigtail, 24 Vac rear w/right pigtail
Product Name
Eaton E2 mining complete molded case circuit breaker
Catalog Number
E2LM3600WS02U42Z12
UPC
782116341320
Product Length/Depth
4.06 in
Product Height
10.75 in
Product Width
8.25 in
Product Weight
20 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Certifications
Contact Manufacturer
Amperage Rating
600 A
Voltage rating
1000Y/577 Vac, 250 Vdc
Trip Type
T207
Circuit breaker type
E2LM
Circuit breaker frame type
Complete breaker
Magnetic trip range
3000-6000A
Shunt trip
12-24 Vac/dc same side with left pigtail shunt
Terminals
Line and load
Undervoltage release
24 Vac rear with right pigtail
Frame
L
Class
Mining
Line
3TA401LDK
Prod load
3TA401LDK
Interrupt rating
42 kAIC at 250 Vdc 65 kAIC at 480 Vac 35 kAIC at 600 Vac 100 kAIC at 240 Vac 10 kAIC at 1000Y/577 Vac
Number of poles
Three-pole
Trip rating
3000-6000 A
Feature → Business Impact → Application: The E2LM3600WS02U42Z12 uses an interchangeable thermal-magnetic trip (T207) with a magnetic trip range of 3000-6000 A, enabling precise coordination and reduced nuisance trips in high fault-current mining feeders and motors. This translates to lower downtime and safer start-up sequences in active mine sites. Application: mining MCCBs in motor control centers and panel boards where consistent fault interruption is critical. Feature → Business Impact → Application: The L-frame, complete three-pole design delivers robust, uniform protection across phase conductors, simplifying wiring and replacement in dusty, aggressive mining environments. Application: control panels and switchgear in underground and surface mining facilities. Feature → Business Impact → Application: Shunt trip capability (12-24 Vac/dc, left side) enables remote tripping for emergency interlocks and safety interlocks, reducing reaction time and improving personnel safety. Application: remote tripping in conveyor, crusher, and ore handling circuits. Feature → Business Impact → Application: Undervoltage release (24 Vac rear, right pigtail) provides fail-safe de-energization and controlled shutoff during power disturbances, protecting both equipment and operators. Application: safety interlock and power-loss scenarios in mining MCCs. Feature → Business Impact → Application: High interrupt ratings (42 kAIC at 250 Vdc, 65 kAIC at 480 Vac, etc.) support rugged fault handling for large mining loads, minimizing equipment damage and feeder interruption time. Application: high-current mining feeders and heavy-duty motor circuits. Feature → Business Impact → Application: Compatibility with E2 mining series and accessories ensures a straightforward upgrade path, reducing retrofit cost and installation time. Application: modernization projects and capacity expansions in mining facilities. The combination of rugged construction, flexible control options, and substantial interrupt capabilities delivers measurable improvements in system availability and safety for mining operations.

Get a Quick Quote for a Eaton E2LM3600WS02U42Z12

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton E2LM3600WS02U42Z12? Enquire Now

FAQs

Mount the 3-pole E2LM3600WS02U42Z12 using the Line and Load terminals specified for a complete L-frame breaker. Ensure correct alignment with the 3TA401LDK line/load designation and accommodate the right-hand undervoltage release and left-side shunt wiring. Verify deep enclosures and proper clearance to manage heat during high-current operation in mining MCCs.
Key specs include a 600 A amperage rating, voltage tolerance of 1000Y/577 Vac and 250 Vdc, and a magnetic trip range of 3000-6000 A with a T207 trip type. Interrupt ratings span up to 65 kAIC at 480 Vac, supporting high fault currents typical in mining environments, while a three-pole design provides balanced protection.
Yes. The device offers a wide magnetic trip range (3000-6000 A) and high interrupt ratings (up to 65 kAIC at 480 Vac), making it well-suited for mining feeders and heavy mine motor circuits where rapid fault interruption minimizes equipment damage and downtime.
Compliance and certification details are provided by the manufacturer, and MSHA-related safety letters are available in Eaton's downloads. For project-specific approvals (CE, UL, IP ratings), contact Eaton to obtain the exact certificates and test reports that apply to your mining installation.
The unit’s rugged L-frame design and interchangeable thermal-magnetic trip reduce maintenance spares and simplify retrofits. Remote shunt and undervoltage release options enable safer, remote control, lowering downtime. With a 1-year installation warranty (or 18 months from shipment) and compatibility within the E2 mining family, total cost of ownership improves over legacy breakers.