Eaton E2ME3800MWU66 Mining MCCB - 65 kAIC at 240V, CSA UL

Part Number: E2ME3800MWU66
Manufacturer
Eaton
Part number
E2ME3800MWU66

Quick Summary

The Eaton E2ME3800MWU66 mining MCCB protects high-current mining feeders with reliable three-pole protection. Underground environments demand dependable protection amid dust, vibration, and tight maintenance windows, making fast installation and robust ratings essential. CSA Certified and UL Listed, this M-frame mining breaker offers 65 kAIC at 240 Vac and an 800 A amperage rating, with 120 Vac undervoltage release options for remote control. The combination of rugged construction, certified safety compliance, and modular E2ME performance supports compliant, high-uptime operation in demanding mines. For engineers and procurement teams, the device provides predictable trip behavior, easier service planning, and compatibility with mining service centers, reducing downtime, inventory complexity, and total cost of ownership.

Product Information

Extended Description

E2ME3800MWU66 Eaton: Eaton E2 mining complete molded case circuit breaker, M-frame, E2ME, Complete breaker, LI trip, 500-2500A trip rating, Three-pole, 800A, 65 kAIC at 240 Vac, 35 kAIC at 480 Vac, 25 kAIC at 600 Vac, 22 kAIC at 250 Vdc, No term., Mining
Product Name
Eaton E2 mining complete molded case circuit breaker
Catalog Number
E2ME3800MWU66
UPC
786685242927
Product Length/Depth
4.06 in
Product Height
8.25 in
Product Width
8.25 in
Product Weight
29 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Certifications
CSA Certified UL Listed
Type
Specialty complete
Amperage Rating
800 A
Voltage rating
600 Vac
Trip Type
T165
Circuit breaker type
E2ME
Circuit breaker frame type
Complete breaker
Magnetic trip range
500-2500A
Terminals
Without terminals
Undervoltage release
120 Vac mining rear with left pigtail
Frame
M
Class
Mining
Interrupt rating
65 kAIC at 240 Vac 22 kAIC at 250 Vdc 35 kAIC at 480 Vac 25 kAIC at 600 Vac
Number of poles
Three-pole
High-current capability enables protection of large mining feeders with minimal fault energy, reducing arc flash exposure and unplanned downtime; this translates to improved uptime and lower maintenance costs on long-wall and room-and-pillar operations. The M-frame, three-pole complete breaker design simplifies integration into modular mining service centers, accelerating panel builds and improving standardization across fleets while maintaining compliance with industry protection standards. An adjustable magnet trip range of 500-2500 A, coupled with a 65 kAIC at 240 Vac and 800 A rating, delivers reliable fault interruption across common mining voltages, supporting safer start-up sequences and predictable tripping behavior in harsh environments. The 120 Vac undervoltage release enables remote and automatic control schemes, enhancing safety interlocks and reducing manual intervention during shift changes. With terminals supplied without, installers gain flexibility to select compatible busbars and accessories, saving material costs and simplifying field upgrades. CSA Certified and UL Listed certifications reinforce regulatory compliance, while the mining-class classification and rugged M-frame construction support long-term performance in underground operations. Real-world mining scenarios benefit from the device’s compact footprint, weight, and mounting compatibility, allowing easier retrofits and service center upgrades without large capital outlays. This translates to lower total cost of ownership, faster ROI, and improved asset reliability in demanding mineral extraction environments.

Get a Quick Quote for a Eaton E2ME3800MWU66

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton E2ME3800MWU66? Enquire Now

FAQs

This unit is a three-pole M-frame breaker shipped without terminals, so plan for compatible busbars and field-installed terminals. It includes an undervoltage release option (120 Vac mining rear with left pigtail) for remote control. Verify panel clearance, mounting orientation, and accessory compatibility to ensure a seamless retrofit into existing mining switchgear and service centers.
The breaker is rated for 800 A at 600 Vac with an interrupt rating up to 65 kAIC at 240 Vac. It supports trip type T165 and a magnetic trip range of 500-2500 A, with three poles. DC interruption capability is 22 kAIC at 250 Vdc. These ratings enable reliable protection for high-current mining feeders under diverse fault conditions.
Yes. The E2 mining MCCB is designed for mining applications with CSA certification and UL listing, reflecting compliance with safety and performance standards. Its M-frame, three-pole construction and robust interrupt ratings make it well-suited for underground feeders, service centers, and other heavy-duty mining installations.
The device is CSA Certified and UL Listed, providing recognized safety and performance validation for regulatory compliance. These certifications support safer operation in mining facilities and help streamline procurement and installation audits.
Eaton’s policy 25-000 governs warranty terms: one year from installation or eighteen months from shipment, whichever occurs first. This provides a clear framework for post-installation support, replacement considerations, and coordinated maintenance planning with your local Eaton service providers.