Eaton EBMBA TT60TED36 - Three-pole TED Explosionproof

Part Number: EBMBA TT60TED36
Manufacturer
Eaton
Part number
EBMBA TT60TED36

Quick Summary

EBMBA TT60TED36 is a rugged three-pole circuit breaker designed for hazardous locations and heavy industrial protection. Engineers face compliance, maintenance, and downtime challenges; this unit targets those pain points with a robust enclosure, copper-free aluminum construction, and a 600 Vac rating. Certifications and standards matter, with NEC/CEC compliance and NEC hazardous ratings (Class I, Division 1 and 2; Class II, Division 1 and 2; Class III), plus versatile NEMA ratings for diverse installations. The combination of a 150 A frame, 10–70 A adjustable amperage, and a bolted/ground joint/gasketed cover supports scalable, code-compliant protection with straightforward installation. This makes it a practical fit for power distribution in process plants, refineries, and offshore rigs.

Product Information

Extended Description

EBMBA TT60TED36 Eaton: Eaton Crouse-Hinds series EBMB circuit breaker, 10A through 70A, TED frame type, Bolted/ground joint/gasketed cover construction, Copper-free aluminum, 150A frame size, General Electric breaker, Three-pole, 60A trip, 600 Vac
Product Name
Eaton Crouse-Hinds series EBMB circuit breaker
Catalog Number
EBMBA TT60TED36
UPC
662276578005
Product Length/Depth
14.78 in
Product Height
19.4 in
Product Width
10.25 in
Product Weight
105 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class II, Division 2 Class III Class I, Division 2 Class I, Division 1 Class II, Division 1
NEMA Rating
3 3R 4 7 9 12
Enclosure
With circuit breaker
Number of poles
Three-pole
Voltage rating
600 Vac
Frame size
150A
Amperage Rating
10 A through 70 A
Manufacturer
General Electric
Circuit breaker frame type
TED
Enclosure cover construction
Bolted/ground joint/gasketed
Enclosure material
Copper-free aluminum
Explosionproof construction and hazardous-location rating protect personnel and assets by containing arcs and preventing ignition in risky environments. The robust enclosure design reduces risk exposure and helps meet NEC/CEC and hazardous-location ratings for Class I, II, and III environments. It is well-suited for operations in chemical plants, oil refineries, and offshore installations, enabling safer starts and reduces incident-related downtime. Three-pole TED frame configuration simplifies protection coordination and motor control, improving system reliability and reducing panel complexity in large-distribution schemes. The 600 Vac rating with a 150 A frame supports mid- to high-load feeders, enabling scalable expansion without retrofit costs while maintaining protective performance in demanding facilities. Bolted/ground joint/gasketed cover construction provides tight sealing against dust, moisture, and corrosive exposures, improving long-term integrity and enabling outdoor or classified-space installations. Copper-free aluminum enclosure delivers corrosion resistance with lighter weight, easing installation and field handling in coastal or chemical environments. The amperage range of 10 A through 70 A, together with a 60 A trip characteristic, offers flexible protection settings for diverse loads while maintaining consistent coordination with upstream/ downstream protective devices. Compatibility with enclosure accessories and standard Eaton/Crouse-Hinds components streamlines procurement, stocking, and service, translating into reduced maintenance inventories and faster response times.

Get a Quick Quote for a Eaton EBMBA TT60TED36

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EBMBA TT60TED36? Enquire Now

FAQs

Follow Eaton’s IF installation sheets referenced in the product downloads, ensuring the enclosure uses the bolted/ground joint/gasketed cover and that mounting clearance complies with NEC guidelines. Use compatible surface or din-rail assemblies, verify torque specifications from official manuals, and confirm conduit entries are sealed to maintain the hazardous-location rating.
The unit is a three-pole breaker rated for 600 Vac with a 150 A frame. Amperage range is 10 A through 70 A, and it supports a 60 A trip characteristic. This combination enables protection for mid-to-high-load feeders while maintaining coordination with upstream protection devices.
Yes. It is designed for hazardous/classified locations with NEC/CEC compliance and NEC hazardous ratings for Class I, Division 1 and 2; Class II, Division 1 and 2; and Class III, making it appropriate for chemical plants, refineries, and offshore environments where ignition risks exist.
It carries NEC/CEC standards, NEC hazardous ratings (Class I, Division 1 and 2; Class II, Division 1 and 2; Class III), and NEMA ratings (3, 3R, 4, 7, 9, 12), aligning with global industry requirements for hazardous locations and rugged installations.
Choose copper-free aluminum enclosure for corrosion resistance and lighter handling, reducing maintenance labor. Leverage bolted/ground joint/gasketed covers for durable sealing, and rely on standard Eaton components for easy replacement and spares. The unit’s wide amperage range and robust frame size minimize the need for mid-cycle retrofits, lowering total cost of ownership over time.