Eaton EBR-3000-2B0IB1 Bus diff relay - High-Impedance

Part Number: EBR-3000-2B0IB1
Manufacturer
Eaton
Part number
EBR-3000-2B0IB1

Quick Summary

The Eaton Bus differential relay EBR-3000-2B0IB1 delivers high-impedance protection for busbars in industrial power systems. Engineers frequently wrestle with nuisance trips and slow fault isolation that disrupt production. While this device supports 50/60 Hz operation and 5 A ratings, we also note conformance expectations and integration capabilities. Regulatory and safety considerations—CE or SIL-style certifications and IP-related protections—should be confirmed with Eaton for your project. In practice, this relay enables seamless SCADA integration via MODBUS/DNP3 while offering robust field installation with conformal coating and projection mounting. This translates to reduced downtime, quicker fault isolation, and clearer communication with protection schemes. Its 7.49 in by 8.62 in by 6.82 in footprint supports compact panel layouts.

Product Information

Extended Description

EBR-3000-2B0IB1 Eaton: Eaton, Bus differential relay , 3000 High Impedance Bus Differential Relay (Requires EBR-Z High Impedance Module), MODBUS/DNP3 (RS485 OR RJ45), Conformal Coating, Projection Mount
Product Name
Eaton Bus differential relay
Catalog Number
EBR-3000-2B0IB1
UPC
786679195901
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Type
Bus differential relay
Burden
10 W / 17 VA
Frequency rating
50/60 Hz
Mounting method
Projection panel
Contact Rating
5 A ac / dc
Operating temperature
-20° to 60°C
Feature: High-impedance bus differential protection. Business Impact: Fast, selective fault detection reduces the extent of outages and lowers energy losses. Application: Ideal for medium-to-large distribution buses in industrial facilities. Feature: MODBUS/DNP3 communications over RS485 or RJ45. Business Impact: Streamlined integration with SCADA and protection schemes, improving situational awareness and control accuracy. Application: Protective relays coordinated with centralized protection architectures. Feature: Projection panel mounting with conformal coating. Business Impact: Accelerated, reliable field installations in harsh environments with longer service life. Application: Outdoor switchyards and factory floors where environmental resistance matters. Feature: 50/60 Hz operation and 5 A contact rating. Business Impact: Broad compatibility with standard power systems and safe, predictable switching performance. Application: Utility-like protection scenes within customer facilities. Feature: Burden 10 W / 17 VA. Business Impact: Manageable power draw that minimizes additional load on power networks while preserving fast tripping. Application: Battery of protection devices sharing limited supply capacity. Feature: Wide operating temperature range -20° to 60°C. Business Impact: Maintains performance across varying plant climates, reducing commissioning risk. Application: Food, pharma, and process industries with fluctuating ambient conditions. Feature: Warranty coverage and manufacturer support. Business Impact: Lower maintenance costs and faster issue resolution. Application: Retrofit projects and new installations seeking long-term reliability.

Get a Quick Quote for a Eaton EBR-3000-2B0IB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EBR-3000-2B0IB1? Enquire Now

FAQs

Installation begins with selecting a projection panel mounting location and verifying panel clearances for the 7.49 in x 8.62 in x 6.82 in footprint. Ensure proper wiring of protection currents and the 5 A ac/dc contacts, then apply conformal coating where required. Use standard torque values and verify conduit entries are sealed for environmental exposure. The unit’s compact form supports rapid retrofit and minimizes panel disruption while maintaining reliable protection.
Plan for 50/60 Hz operation, a 5 A contact rating, and a burden of 10 W / 17 VA. The device uses a projection panel mounting method and operates across -20 to 60°C ambient. Ensure compatible protection schemes and wiring with MODBUS/DNP3 (RS485 or RJ45) to integrate feedback signals into SCADA and control systems. These specs support fast, selective tripping with minimal nuisance trips.
Yes. The relay supports MODBUS/DNP3 communications over RS485 or RJ45, enabling direct data exchange with SCADA systems and protection relays. This integration improves fault visibility, timing coordination, and operator situational awareness. When wiring, ensure correct termination, proper shielding, and adherence to RS485 or RJ45 standards to maintain communication integrity in industrial environments.
Compliances are listed as Manufacturer-verified for this model, so confirm current certifications with Eaton for your project. Typical considerations include CE and SIL-related requirements and IP protections relevant to your site. Always request the latest certification documents from Eaton to ensure your installation meets local regulations and safety standards.
The EBR-3000-2B0IB1 delivers faster, selective protection, reducing fault duration and downtime while improving protection coordination with SCADA. The device’s compatibility with MODBUS/DNP3 and its robust mounting and environmental features lower commissioning risk and maintenance costs. Over time, these benefits translate into higher system availability, reduced repair expenses, and clearer, data-driven protection decisions.