Eaton Bus differential relay EBR-3Z-2B0KA1-B - 61850/MODBUS/DNP3

Part Number: EBR-3Z-2B0KA1-B
Manufacturer
Eaton
Part number
EBR-3Z-2B0KA1-B

Quick Summary

Bus differential relay solutions protect high-impedance bus systems by delivering fast, selective protection for substations and feeder networks. Operators often struggle with nuisance tripping and protection coordination, especially during transient faults. This Eaton model aligns with industry expectations for reliability, featuring potential SIL-ready protection, CE compliance considerations, and a rugged enclosure for demanding environments. It supports 50/60 Hz operation, a 5 A contact rating, and a common bezel with the EBR-Z High Impedance Module, simplifying installation. With 61850/MODBUS/DNP3 communications and projection mounting, it enables scalable protection architectures while reducing maintenance costs and downtime for utility and industrial feeders.

Product Information

Extended Description

EBR-3Z-2B0KA1-B Eaton: Eaton, Bus differential relay , 3000 High Impedance Bus Differential Relay and EBR-Z High Impedance Module in common bezel, 61850/MODBUS/DNP3 (FO LC), Projection Mount, 10.4kJ
Product Name
Eaton Bus differential relay
Catalog Number
EBR-3Z-2B0KA1-B
UPC
786679195734
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
13.64 in
Product Weight
12.7 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Type
Bus differential relay
Burden
10 W / 17 VA
Frequency rating
50/60 Hz
Mounting method
Projection panel
Contact Rating
5 A ac / dc
Operating temperature
-20° to 60°C
Feature: High impedance bus differential protection reduces false trips and enhances selectivity. Business Impact: Improves reliability and minimizes outage duration, reducing overall maintenance costs. Application: Ideal for substations and industrial feeders requiring robust fault discrimination. Feature: Projection panel mounting simplifies retrofit and new installs by aligning with standard electrical cabinets. Business Impact: Speeds up commissioning and lowers installation labor. Application: Retrofit projects where space and alignment matter. Feature: Common bezel integration with EBR-Z High Impedance Module enables modular upgrades. Business Impact: Flexible protection architectures and future-proof scalability. Application: Centralized protection schemes across multiple feeders. Feature: 61850/MODBUS/DNP3 communication enables seamless integration with modern substations. Business Impact: Real-time monitoring, easier diagnostics, and improved asset visibility. Application: Digital protection schemes and SCADA-enabled plants. Feature: Burden of 10 W / 17 VA and 5 A contact rating support reliable signaling without excessive power draw. Business Impact: Reduced wiring complexity and predictable performance under fault conditions. Application: Control room and field panel installations in harsh environments. The content emphasizes measurable outcomes like efficiency gains, compliance alignment, and installation advantages, while addressing common objections such as retrofit complexity and integration with existing SCADA systems.

Get a Quick Quote for a Eaton EBR-3Z-2B0KA1-B

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EBR-3Z-2B0KA1-B? Enquire Now

FAQs

What mounting and clearance are required when installing the EBR-3Z-2B0KA1-B in a projection-panel environment? This model supports projection panel mounting and common bezel configurations with the EBR-Z High Impedance Module, enabling straightforward alignment with standard cabinets. Ensure adequate space for wiring, maintain required clearance for heat dissipation, and verify the panel is rated for -20 to 60°C ambient conditions to preserve performance and life.
Key parameters include 50/60 Hz operation, a 5 A contact rating, a burden of 10 W / 17 VA, and a projection-mount design. The relay is designed to perform under typical substations conditions, offering fast differential protection while maintaining signal integrity with 61850/MODBUS/DNP3 communications. Ensure compatible power and wiring to minimize nuisance trips and maintain coordination with upstream protections.
Yes. The EBR-3Z-2B0KA1-B is built for high-impedance bus differential scenarios, providing fast fault detection and selective tripping to protect bus bars and feeders. It integrates with common Eaton bezel modules, supports digital communication protocols, and is designed to simplify integration with modern SCADA and substation automation schemes while ensuring reliable protection in challenging environments.
Compliances are listed as Contact Manufacturer, so confirm the exact certifications with Eaton for your region. Typical concerns include CE marking for European compliance, SIL-ready protection for system reliability, and IP-rated enclosures for outdoor or harsh environments. Always verify current certifications prior to procurement to ensure regulatory alignment and project approval.
ROI stems from reduced outage duration, improved protection coordination, and lower maintenance labor due to modular bezel integration. The one-year warranty offers initial risk reduction. For ongoing value, implement periodic diagnostics via 61850/MODBUS/DNP3 interfaces, maintain firmware updates, and schedule routine testing of protection functions to sustain reliability and minimize unplanned downtime.