Eaton EBR-3Z-2B0TA0-B Bus differential relay - High Impedance

Part Number: EBR-3Z-2B0TA0-B
Manufacturer
Eaton
Part number
EBR-3Z-2B0TA0-B

Quick Summary

Eaton Bus differential relay protects bus sections by detecting differential currents in power distribution networks. Engineers often struggle to coordinate protection schemes across modular bus bars while maintaining fast, reliable trips. Compliances require manufacturer confirmation; consult Eaton for specifics on any SIL, CE, or IP-related certifications. This module supports 61850/MDBS/DNP3 (RS485 RJ45) and standard mounting, delivering robust protection with a compact footprint. The combination of protection intelligence and straightforward installation helps accelerate projects, reduce downtime, and simplify integration with Eaton’s protection ecosystem, enabling better reliability across industrial automation and power distribution architectures.

Product Information

Extended Description

EBR-3Z-2B0TA0-B Eaton: Eaton, Bus differential relay , 3000 High Impedance Bus Differential Relay and EBR-Z High Impedance Module in common bezel, 61850/MDBS/DNP3 (RS485 RJ45), Standard Mount, 10.4kJ
Product Name
Eaton Bus differential relay
Catalog Number
EBR-3Z-2B0TA0-B
UPC
786679196052
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
13.64 in
Product Weight
12.7 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Type
Bus differential relay
Burden
10 W / 17 VA
Frequency rating
50/60 Hz
Mounting method
Standard
Contact Rating
5 A ac / dc
Operating temperature
-20° to 60°C
Feature: High impedance differential protection delivers selective fault detection. Benefit: Reduces unnecessary trips and limits outage scope, improving plant availability. Application: Medium to large industrial power distribution where rapid, selective bus protection is critical. Feature: Common bezel with EBR-Z High Impedance Module simplifies installation. Benefit: Streamlines retrofits and upgrades, lowering on-site labor and commissioning time. Application: Upgrading legacy switchgear without extensive cabinet changes. Feature: 61850/MDBS/DNP3 (RS485 RJ45) communications enable easy SCADA and protection-system integration. Benefit: Improves data accuracy and remote configuration, reducing engineering time and human error. Application: Substation and plant automation environments requiring modern communication protocols. Feature: Standard mounting and robust mechanical design suited for industrial environments. Benefit: Fast, predictable installation with minimal custom hardware. Application: New builds and upgrade projects across manufacturing facilities. Feature: 5 A contact rating with a 10 W / 17 VA burden. Benefit: Supports signal-level control circuits without loading power systems, delivering reliable operation with modest power draw. Application: Control circuit interfaces in protection schemes. Feature: Wide operating temperature range (-20° to 60°C) and field-proven reliability. Benefit: Maintains protective performance in harsh industrial conditions, reducing maintenance frequency. Application: Outdoor and indoor switchgear, data centers, and process plants. Feature: 10.4 kJ trip energy specification indicates strong fault-energy handling. Benefit: Improves stability under high-energy faults, enhancing system resilience. Application: High-energy fault scenarios in large bus architectures.

Get a Quick Quote for a Eaton EBR-3Z-2B0TA0-B

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EBR-3Z-2B0TA0-B? Enquire Now

FAQs

The relay is designed for standard mounting and shared bezel configurations, enabling straightforward retrofits or new installations within Eaton protection ecosystems. It supports common interfaces such as 61850 MDBS and DNP3 over RS485 RJ45 for seamless SCADA integration, minimizing panel rework and reducing commissioning time.
Key specs include 50/60 Hz operation, 5 A contact rating for ac/dc signaling, and a burden of 10 W / 17 VA. The device also provides high-impedance bus differential protection with a trip energy rating of 10.4 kJ, supporting reliable fault discrimination in complex bus configurations.
Yes. The EBR-3Z-2B0TA0-B is designed for high-impedance differential protection, providing selective tripping to improve system reliability in medium to large bus architectures while reducing nuisance trips and disturbance to adjacent feeders.
Compliances are listed as ‘Contact Manufacturer’ for final certification details. For project-specific requirements (SIL, CE, IP, etc.), consult Eaton directly to confirm applicable certifications and any documentation needed for your regulatory environment.
The device’s standard mounting, common bezel, and RS485 communication simplify installation and commissioning, reducing labor costs. Its robust protection and fast, selective tripping minimize downtime, while 61850 compatibility supports remote monitoring and faster fault resolution, delivering measurable ROI through improved uptime and simplified operations.