Eaton ED2N22171113S Linear Fluorescent Light Fixture - IP66

Part Number: ED2N22171113S
Manufacturer
Eaton
Part number
ED2N22171113S

Quick Summary

Eaton ED2N22171113S linear fluorescent light fixture provides reliable ceiling-mounted illumination for hazardous locations. In harsh industrial settings, downtime and maintenance complexity can erode safety and productivity. This fixture is built for Hazardous/Classified Locations, with NEC/CEC compliance, IP66 protection, and a NEMA 4X enclosure to withstand corrosive environments. Designed for 120–277 Vac operation and 2-lamp T8 bi-pin lamps, it supports robust, compliant lighting in demanding facilities. By combining rugged enclosure materials with a stainless steel latch and polycarbonate lens, this solution reduces maintenance cycles while delivering dependable performance in plants, refineries, and other critical operations. The ED2N2200-series ecosystem also aligns with Pauluhn ECOS design principles for easy integration with existing control schemes and maintenance workflows.

Product Information

Extended Description

ED2N22171113S Eaton: Eaton Crouse-Hinds series Pauluhn ECOS ED2N linear fluorescent,3/4" Myers hubs,316 SS,one entry at each end,2 ft,Polycarbonate lens,T8 bi-pin,Fiberglass-reinforced polyester,2-lamp,Stainless steel latch,Ceiling,120-277 Vac,17W
Product Name
Eaton Crouse-Hinds series Pauluhn ECOS ED2N linear fluorescent light fixture
Catalog Number
ED2N22171113S
UPC
662276433533
Product Length/Depth
29 in
Product Height
5.6 in
Product Width
8.5 in
Product Weight
9 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 1 Class III
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lamp type
Fluorescent
Lamp length
2 ft
Light type
T8 bi-pin
Voltage rating
120-277 Vac
Frequency rating
50/60 Hz
Mounting
Ceiling
Entry size
3/4"
Entry type
Myers hub, 316 stainless steel, one entry each end
Wattage
17W
Number of lamps
2-lamp
Material
Fiberglass-reinforced polyester
Lens material
Polycarbonate
Special features
Stainless steel latch
Feature: Hazardous location readiness with NEC/CEC compliance → Benefit: Simplified regulatory approval and safer operations in Class I, II, and III environments, enabling faster project sign-off and reduced risk during commissioning. Application: First-fit choice for processing plants and refineries where compliance drives downtime avoidance. Feature: IP66/NEMA 4X rated enclosure → Benefit: Superior dust and water ingress protection, extending fixture life in harsh industrial spaces; Application: Outdoor and wet indoor areas such as washdown zones and outdoor racks. Feature: 2-lamp 17W design with T8 bi-pin lamps → Benefit: Efficient lighting with low energy draw and long-lamp life, reducing operating costs and maintenance frequency; Application: Continuous process areas, corridors, and workstations requiring consistent illumination. Feature: Fiberglass-reinforced polyester body with 316 stainless end entries → Benefit: Corrosion resistance and structural durability in chemically aggressive environments; Application: Chemical plants, offshore facilities, and coastal installations. Feature: Polycarbonate lens and stainless steel latch → Benefit: Impact resistance and secure, reliable access for quick service; Application: Enclosures and fixtures that endure frequent maintenance checks. Feature: 120–277 Vac universal voltage and 50/60 Hz compatibility → Benefit: Flexible installation across global sites without voltage conversion; Application: Multi-site deployments and retrofits. Industry context: The ED2N family aligns with Pauluhn ECOS standards, supporting seamless integration with existing industrial control architectures and maintenance routines.

Get a Quick Quote for a Eaton ED2N22171113S

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton ED2N22171113S? Enquire Now

FAQs

The ED2N22171113S is designed for ceiling mounting with entry sizes of 3/4" at each end using Myers hubs. For installation, connect 120–277Vac supply per local code, mount the fixture securely to the ceiling, and ensure wiring clearance for the end-entry hubs. The stainless steel latch provides quick access during maintenance without compromising ingress protection.
This fixture operates on 120–277 Vac at 50/60 Hz, using two T8 bi-pin lamps for a total of 34W. Each lamp is 17W, delivering efficient, continuous illumination. The unit is IP66 and NEMA 4X rated, with a 29 in length and a compact footprint suitable for restricted ceilings in industrial spaces.
Yes. The ED2N22171113S carries Hazardous/Classified Locations ratings, aligned with NEC/CEC standards, and is designed for Class I, Division 2; Class II, Division 1; and Class III environments. It is built to meet the stringent requirements of hazardous-area lighting while maintaining reliable performance.
Documentation includes UL certification pages for hazardous, harsh, and marine linear fluorescent fixtures, along with IP66 and NEMA 4X classifications. The product is supported by Eaton’s installation instructions and a dedicated specification sheet for ED2N22171113S to assist in audits and commissioning.
The ED2N fixture offers corrosion-resistant materials, a stainless steel latch, polycarbonate lens, and 2-lamp efficiency, which collectively reduce maintenance cycles and downtime. Its universal voltage range simplifies multi-site deployments, contributing to lower spare-part inventories and faster site scalability.