Eaton ED2N42171012 Linear Fluorescent Light - IP66/NEMA 4X
Part Number: ED2N42171012
Quick Summary
The Eaton ED2N42171012 linear fluorescent light fixture delivers rugged, reliable illumination for hazardous and classified locations. Facility teams often wrestle with ingress, corrosion, and maintenance in harsh environments, making durable lighting a key safety and uptime driver. This luminaire carries NEC/CEC compliance with Class I Division 2 ratings, IP66 ingress protection, and a NEMA 4X enclosure to protect critical assemblies. Designed for ceiling mounting in a 4 ft, 2-lamp configuration, it supports 120–277 VAC power and helps reduce energy use and replacement cycles. For industrial plants, refineries, and offshore sites, it delivers consistent performance while meeting stringent codes and safety standards.
Product Information
Extended Description
ED2N42171012 Eaton: Eaton Crouse-Hinds series Pauluhn ECOS ED2N linear fluorescent light fixture,3/4" Myers conduit hubs,zinc,one entry at each end,4 ft,Polycarbonate lens,T8 bi-pin,Fiberglass-reinforced polyester,Ceiling mount,2-lamp,120-277 Vac,32W
Product Name
Eaton Crouse-Hinds series Pauluhn ECOS ED2N linear fluorescent light fixture
Catalog Number
ED2N42171012
UPC
662276420342
Product Length/Depth
53 in
Product Height
5.6 in
Product Width
8.5 in
Product Weight
17 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 1 Class III
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lamp type
Fluorescent
Lamp length
4 ft
Light type
T8 bi-pin
Voltage rating
120-277 Vac
Frequency rating
50/60 Hz
Mounting
Ceiling
Entry size
3/4"
Entry type
Myers conduit hubs, zinc, one entry at each end
Wattage
32W
Number of lamps
2-lamp
Material
Fiberglass-reinforced polyester
Lens material
Polycarbonate
Eaton Crouse-Hinds ED2N42171012 3D drawing
Crouse-Hinds series Pauluhn ECOS Linear Fluorescent brochure
Crouse-Hinds series Pauluhn ECOS Linear Fluorescent catalog page
Pauluhn ECOS Hazardous, Harsh and Marine Linear Fluorescent Light Fixtures Canadian certification
Pauluhn ECOS Hazardous, Harsh and Marine Linear Fluorescent Light Fixtures Canadian certification
IF LBL1584 - Pauluhn ECOS ED2N Series Linear Fluorescent
Eaton Specification Sheet - ED2N42171012
Feature → Business Impact → Application: The ED2N42171012 uses a 53 in length, 4 ft lamping configuration with 32 W fluorescent lamps (T8 bi-pin) and a polycarbonate lens for high optical clarity and impact resistance. This translates to reliable illumination with minimal maintenance downtime in harsh industrial environments, such as chemical plants and refineries. Application: long runs in hazardous locations requiring consistent lighting without frequent lens or housing replacements. Feature → Business Impact → Application: IP66 sealed enclosure plus NEMA 4X corrosion and water protection provides robust ingress protection against dust, water, and chemical exposure. Benefit: extended service life and reduced risk of moisture-related outages in wet, dusty, or corrosive settings. Application: washdown zones, outdoor industrial facilities, and offshore platforms. Feature → Business Impact → Application: Fiberglass-reinforced polyester housing coupled with a polycarbonate lens delivers chemical resistance and rugged durability. Benefit: lower lifecycle costs and fewer field failures under harsh chemical exposure; Application: chemical processing lines and mining operations. Feature → Business Impact → Application: Ceiling mount with 3/4" Myers conduit hubs, one entry at each end, supports flexible installation and easy retention in retrofit projects. Benefit: simplified installation and compatibility with existing conduit systems; Application: retrofit in aging facilities or new-builds with established electrical pathways. Feature → Business Impact → Application: Wide voltage range 120–277 VAC and 50/60 Hz operation enables compatibility across international sites without custom power supplies. Benefit: reduces part diversity, accelerates procurement, and lowers inventory costs; Application: global industrial deployments and multi-site operations. Feature → Business Impact → Application: Hazardous/Classified Locations area classification and NEC/CEC compliance ensure regulatory alignment and worker safety. Benefit: risk mitigation, insurance alignment, and smoother commissioning; Application: any facility operating under strict electrical codes.
Get a Quick Quote for a Eaton ED2N42171012
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ED2N42171012?
Enquire Now
FAQs
The ED2N42171012 is designed for ceiling mounting and features 3/4" Myers conduit hubs with one entry at each end, simplifying retrofits and new installations. With a 53 in length and a 4 ft lamping configuration, it fits standard industrial ceilings while accommodating common wiring practices and ballast access for service.
This luminaire meets NEC/CEC standards and is certified for Hazardous/Classified Locations with Class I, Division 2; Class II, Division 1; and Class III ratings. It also features IP66 ingress protection and a NEMA 4X enclosure, ensuring safe operation in demanding environments.
Ideal applications include chemical plants, oil and gas facilities, refineries, mining, and offshore platforms where hazardous conditions and exposure to dust, water, or chemicals necessitate robust, sealed lighting with long service life and reliable performance.
With a fiberglass-reinforced polyester housing and polycarbonate lens, the ED2N42171012 offers excellent chemical and impact resistance, reducing frequent replacements. Its 2-lamp, 32 W design provides stable illumination with lower energy consumption, minimizing ongoing maintenance and energy costs over its service life.
The fixture operates on 120–277 VAC at 50/60 Hz and is rated for two fluorescent lamps (32 W total). Its wide voltage range and 4 ft footprint enable easy integration into varied electrical systems, supporting quick deployment across multi-site operations while maintaining code compliance.