Eaton ED2N42572012 Linear Light Fixture - IP66
Part Number: ED2N42572012
Quick Summary
Eaton ED2N42572012 linear fluorescent light fixture delivers rugged illumination for hazardous locations. In demanding environments, downtime and safety compliance gaps drive maintenance costs. It carries NEC/CEC compliance for Class I, Division 2, a NEMA 4X enclosure, and IP66 ingress protection. With 53 in length, 4 ft lamp configuration, 120–277 VAC operation, and a wall-mount design, it reduces installation time while delivering consistent lighting. Designed for easy maintenance, the unit uses T5HO bi-pin lamps and a polycarbonate lens, improving reliability in dusty or wet facilities. This combination of rugged build and industry certifications translates into lower total cost of ownership and safer, compliant operation.
Product Information
Extended Description
ED2N42572012 Eaton: Eaton Crouse-Hinds series Pauluhn ECOS ED2N linear fluorescent light fixture,3/4" Myers conduit hubs,zinc,one entry at each end,4 ft,Polycarbonate lens,T5HO bi-pin,Fiberglass-reinforced polyester,2-lamp,Wall,120-277 Vac,54W
Product Name
Eaton Crouse-Hinds series Pauluhn ECOS ED2N linear fluorescent light fixture
Catalog Number
ED2N42572012
UPC
662276437906
Product Length/Depth
53 in
Product Height
5.6 in
Product Width
8.5 in
Product Weight
16.1 lb
Area classification
Hazardous/Classified Locations
Standards type
NEC/CEC
NEC hazardous rating
Class I, Division 2 Class II, Division 1 Class III
NEMA Rating
4X
Ingress protection (IP) ratings
IP66
Lamp type
Fluorescent
Lamp length
4 ft
Light type
T5HO bi-pin
Voltage rating
120-277 Vac
Frequency rating
50/60 Hz
Mounting
Wall
Entry size
3/4"
Entry type
Myers conduit hubs, zinc, one entry at each end
Wattage
54W
Number of lamps
2-lamp
Material
Fiberglass-reinforced polyester
Lens material
Polycarbonate
Eaton Crouse-Hinds ED2N42572012 3D drawing
Crouse-Hinds series Pauluhn ECOS Linear Fluorescent brochure
Crouse-Hinds series Pauluhn ECOS Linear Fluorescent catalog page
Pauluhn ECOS Hazardous, Harsh and Marine Linear Fluorescent Light Fixtures Canadian certification
Pauluhn ECOS Hazardous, Harsh and Marine Linear Fluorescent Light Fixtures Canadian certification
IF LBL1584 - Pauluhn ECOS ED2N Series Linear Fluorescent
Eaton Specification Sheet - ED2N42572012
Feature: Hazardous location suitability for NEC/CEC Class I, Division 2. Business Impact: Ensures regulatory compliance and reduced safety risk in process plants and chemical facilities. Application: Suitable for chemical processing floors, refineries, and offshore environments where hazardous atmospheres require certified lighting. Feature: IP66 ingress protection and NEMA 4X enclosure. Business Impact: Delivers durable protection against dust, water jets, and corrosion, minimizing maintenance cycles. Application: Ideal for washdown zones, outdoor-rated enclosures, and marina/lacustrine settings where cleanliness and weather sealing matter. Feature: 2-lamp, 54W configuration. Business Impact: Provides even illumination with energy efficiency, lowering fixture count and energy costs. Application: Long aisles, workstations, and clean/dirty process areas where uniform light is critical. Feature: T5HO bi-pin lamps and polycarbonate lens. Business Impact: Simplifies lamp replacement and maintains clear light transmission in harsh environments. Application: Quick maintenance in inventory-heavy facilities, reducing downtime. Feature: Fiberglass-reinforced polyester housing with zinc Myers conduit hubs (one end entry each). Business Impact: Tough, chemical-resistant housing supports long service life and straightforward field wiring. Application: Wall-mounted installations in industrial buildings. Feature: 53 in length and wall mounting. Business Impact: Fits standard spaces, enables modular retrofits, and reduces installation complexity. Application: Corridors and work areas in industrial plants requiring durable, code-compliant lighting. The result is measurable cost of ownership reduction, safer operations, and dependable performance in demanding facilities.
Get a Quick Quote for a Eaton ED2N42572012
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton ED2N42572012?
Enquire Now
FAQs
The ED2N42572012 is designed for hazardous and classified locations, including Class I, Division 2 environments, where robust protection against dust, moisture, and corrosive exposure is required. Its wall-mount configuration, 53-inch length, and 3/4 inch entry size with Myers conduit hubs at both ends simplify mounting in tight industrial spaces. This makes it ideal for process areas, chemical plants, and offshore facilities, reducing downtime during installation and future servicing.
This fixture carries NEC/CEC compliance for hazardous locations, including Class I, Division 2, along with a NEMA 4X enclosure and IP66 ingress protection. These certifications ensure safe operation in harsh industrial areas, provide weather and washdown resistance, and support compliance with relevant safety and electrical standards in North American facilities.
The ED2N42572012 operates at 120–277 VAC and 50/60 Hz, uses a 4 ft lamp length, and delivers 54W across 2 lamps. It is wall-mounted with 3/4 inch entry hubs, zinc Myers conduit entries at each end, and a 53 inch overall length. The housing is fiberglass-reinforced polyester with a polycarbonate lens, facilitating straightforward wiring and reliable field service.
With a 54W two-lamp configuration and a long 53-inch footprint, lighting is spread evenly, reducing shadows and the need for additional luminaires. The T5HO bi-pin lamps offer efficient light output, while the polycarbonate lens maintains high transmission. The durable IP66/NEMA 4X construction minimizes maintenance downtime in harsh environments, lowering total cost of ownership over the product life cycle.
Consider the hazardous-location certifications, IP66/NEMA 4X protection, and 120–277 VAC compatibility to ensure regulatory compliance and future-proofing. Factor in installation simplicity due to dual-end entries and wall mounting, reduced maintenance downtime from robust housing and easy lamp replacement, and energy savings from the 54W, two-lamp configuration when calculating ROI over the fixture’s life.