Eaton EDR-3000-2A0BB0 Distribution Relay - RS485 Modbus RTU
Part Number: EDR-3000-2A0BB0
Quick Summary
Eaton distribution relay EDR-3000-2A0BB0 provides centralized feeder protection and monitoring for industrial power systems. Engineers often struggle to integrate protective relays with Modbus RTU or DNP3 RTU over RS485 within modern automation architectures, causing delays and compatibility issues. Note that compliances are listed as 'Contact Manufacturer'—confirm CE, SIL, and IP ratings with Eaton during procurement. This device pairs with RS485 networks and supports feeder protection, metering, and easy installation, delivering reliability, scalability, and measurable reductions in downtime and energy waste for panel builders and plant owners.
Product Information
Extended Description
EDR-3000-2A0BB0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, over RS-485,19-300Vdc, 40-250Vac, 50/60 Hz
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2A0BB0
UPC
786679141243
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
1
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
E-series protective relays
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Eaton Specification Sheet - EDR-3000-2A0BB0
Selling Policy 25-000 - Distribution and Control Products and Services
RS485 communications with Modbus RTU or DNP3 RTU enable seamless SCADA integration and remote monitoring, improving visibility and fault diagnostics while reducing现场 maintenance visits. This translates to faster fault isolation and lower downtime costs in busy production lines. The 19-300 VDC and 40-250 VAC power supply range supports multi-volt environments, simplifying procurement and wiring across diversified plant floors and expanding compatibility with existing control panels. With four inputs and four outputs, the EDR-3000-2A0BB0 provides flexible local control and metering for feeder protection, energy accounting, and conditional interlocking, enabling precise zone control and reduced misoperations. Conformal coating enhances reliability in humid or dusty environments, extending service life in outdoor enclosures and washdown areas, while removable terminals streamline installation and field maintenance, cutting commissioning time by hours. A compact semi-flush mounting footprint, combined with a robust protection profile, helps accelerate retrofit projects without sacrificing space or safety. In short, the EDR-3000-2A0BB0 delivers dependable protection, faster commissioning, and lower total cost of ownership in demanding industrial settings.
Get a Quick Quote for a Eaton EDR-3000-2A0BB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-3000-2A0BB0?
Enquire Now
FAQs
Installation involves mounting the device in the panel with the semi-flush method, attaching the four removable terminals, and wiring the four inputs/outputs to the feeder circuits. Use RS485 for Modbus RTU or DNP3 RTU communication to your SCADA or PLC. The conformal coating aids reliability in harsh environments, while the 19–300 Vdc / 40–250 Vac range accommodates mixed supply conditions.
Key specs include four 4-channel inputs/outputs, a power-supply range of 19–300 Vdc and 40–250 Vac, 50/60 Hz operation, and current sensing inputs rated at 5A and 1A phase currents. It supports Modbus RTU or DNP3 RTU over RS485 for remote monitoring and control, making it suitable for feeder protection and metering.
Yes. The EDR-3000-2A0BB0 is designed for RS485 communication with either Modbus RTU or DNP3 RTU, enabling straightforward integration with existing SCADA systems and PLCs. This compatibility simplifies data exchange for protection, metering, and remote control across distributed feeder networks.
Compliances are listed as 'Contact Manufacturer' for this model. It is important to confirm CE marking, SIL, and IP ratings directly with Eaton to ensure alignment with your site requirements and applicable electrical safety standards before deployment.
The ROI improves through reduced downtime, faster fault diagnosis, and easier maintenance due to removable terminals and RS485 connectivity for remote monitoring. Plan proactive inspections aligned with Eaton’s warranty policy, 1 year from installation (or 18 months from shipment), to maximize uptime and extend service life of feeder protection equipment.