Eaton EDR-3000-2A0EA0 Distribution Relay - Profibus-DP/RS-485

Part Number: EDR-3000-2A0EA0
Manufacturer
Eaton
Part number
EDR-3000-2A0EA0

Quick Summary

EDR-3000 distribution relay provides robust feeder protection and control for industrial panels. Operators often struggle with wiring complexity and inconsistent diagnostics when adding remote-capable relays. Compliance status is region-dependent; verify with Eaton, with common targets including CE/UL and IP considerations as applicable. This 4-in/4-out device supports Profibus-DP over D-Sub/RS-485, wide power ranges, and removable terminals, delivering streamlined procurement and faster maintenance. By consolidating protection, metering, and communication in one compact unit, it helps lower panel footprint while boosting uptime and network visibility in automated feeder networks.

Product Information

Extended Description

EDR-3000-2A0EA0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, over D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2A0EA0
UPC
786679142806
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
1
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Feature: 4 inputs and 4 outputs with removable terminals → Business Impact: simplifies wiring changes during commissioning and field upgrades, reducing installation time and risk. Application: ideal for panel feeders needing flexible I/O with easy maintenance. Feature: Wide power supply range 19-300Vdc and 40-250Vac, 50/60 Hz → Business Impact: supports multi-site installations with a single relay family, lowering spare-part variety and inventory costs. Application: suitable for mixed-voltage control systems in modern factories. Feature: Profibus-DP over D-Sub / RS-485 communication → Business Impact: enables seamless integration into existing Profibus networks, improving diagnostics and remote control. Application: networked automation environments requiring reliable fieldbus signaling. Feature: Current sensing inputs and phase current options (1 input; 5A, 1A) → Business Impact: precise protection and metering support, improving trip accuracy and energy visibility. Application: feeder protection with metering capabilities for asset optimization. Feature: Semi-flush mounting with removable terminals and a compact footprint → Business Impact: space-efficient installation with straightforward field maintenance and faster cabinet reconfiguration. Application: control panels where panel real estate is at a premium. Feature: Base relay compatibility (EDR-3000) and 4x I/O → Business Impact: modular upgrade path and scalable protection schemes, reducing total cost of ownership. Application: retrofit projects and new feeder installations demanding expandability.

Get a Quick Quote for a Eaton EDR-3000-2A0EA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2A0EA0? Enquire Now

FAQs

For installation, plan a semi-flush mounting approach to maximize panel space and ensure adequate clearance for removable terminals. Confirm power supply compatibility (19-300Vdc or 40-250Vac, 50/60 Hz) and allocate 4 input and 4 output channels for your feeder configuration. Use the removable terminals to simplify wiring changes during commissioning and future upgrades, reducing on-site downtime.
The EDR-3000-2A0EA0 communicates via Profibus-DP over a D-Sub connector using RS-485 signaling, enabling integration into existing Profibus networks. This simplifies remote monitoring, fault reporting, and parameterization from a centralized control system. Ensure proper bus termination and address configuration to minimize communication errors in noisy industrial environments.
Yes. With 4 inputs and 4 outputs, current sensing and metering capabilities, and wide supply compatibility, the relay is well-suited for feeder protection in panels serving multiple machines or lines. The ability to interface via Profibus-DP facilitates integration with PLCs and SCADA for centralized protection coordination and improved uptime.
Compliance details are provided by the manufacturer and can vary by region. The product listing notes 'Compliances: Contact Manufacturer,' so consult Eaton’s datasheet or regional reps to confirm CE, UL, IP ratings, and other regulatory requirements relevant to your installation and enclosure specifications.
The relay’s removable terminals, compact footprint, and 4x I/O configuration streamline maintenance and future upgrades, reducing panel downtime. Profibus-DP networking provides centralized diagnostics and remote monitoring, improving mean time between failures (MTBF) and enabling faster fault isolation, which translates to lower operating costs and higher system availability.