Eaton EDR-3000-2A0GB1 Distribution Relay - RS-485 Modbus

Part Number: EDR-3000-2A0GB1
Manufacturer
Eaton
Part number
EDR-3000-2A0GB1

Quick Summary

The Eaton distribution relay is a robust solution for protecting and monitoring feeder circuits in industrial plants. It addresses the common challenge of integrating remote monitoring across mixed voltage environments and multiple control protocols. Key certifications to confirm with the manufacturer include SIL, CE, and IP ratings to meet regional safety and reliability expectations. This model delivers scalable protection and metering with Modbus RTU and DNP3 RTU communications, enabling operators to optimize feeder reliability, reduce downtime, and lower total cost of ownership through centralized control and visibility.

Product Information

Extended Description

EDR-3000-2A0GB1 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2A0GB1
UPC
786679142851
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
0
Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over RS-485 enables seamless integration with existing SCADA and protection schemes, reducing wiring complexity and commissioning time while improving data accessibility for real-time decision making in feeders and substation sections. Application: Use in plant feeders and utility feeders where remote monitoring is critical for uptime. Feature → Business Impact → Application: Wide power-supply range of 19-300 Vdc and 40-250 Vac, 50/60 Hz operation supports mixed electrical infrastructures, minimizing power-interface redesign and enabling single-stock utility across sites. Application: Deploy across multi-voltage facilities to simplify procurement. Feature → Business Impact → Application: Four inputs and four outputs with removable terminals simplify field configuration and quick replacement, reducing downtime and labor costs during maintenance. Application: Ideal for modular feeder protection and signaling in harsh environments. Feature → Business Impact → Application: Current protection and metering with configurable phase currents (5A, 1A) deliver precise protection settings and accurate energy reporting, improving protection coordination and energy visibility. Application: Used for feeder metering and overload protection in manufacturing lines. Feature → Business Impact → Application: Conformal coating and projection mounting enhance ruggedness and ease of installation in industrial cabinets, enabling reliable operation in damp or dusty environments. Application: Suitable for harsh plant floors and outdoor enclosures with proper housing. Feature → Business Impact → Application: 4-channel capability supports complex interlocking schemes with zone selective interlocking set to 0 in this model, enabling scalable protection schemes and reduced wiring. Application: Growth-ready protection for expanding feeder networks. Feature → Business Impact → Application: Extended warranty options through Eaton’s policy provide risk mitigation for long-term maintenance budgeting and system uptime. Application: Useful for lifecycle planning and supplier reliability in OEM and end-user facilities.

Get a Quick Quote for a Eaton EDR-3000-2A0GB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2A0GB1? Enquire Now

FAQs

Prepare the panel space, mount the unit (projection mounting), and connect the four inputs and four outputs to the protected feeder. Wire the RS-485 Modbus RTU or DNP3 RTU communication to the existing SCADA bus via the removable terminals, set addressing, and configure 50/60 Hz operation. Ensure proper polarity and grounding per Eaton guidelines.
Power supply range is 19-300 Vdc and 40-250 Vac, with a 50/60 Hz frequency rating. It provides four inputs and four outputs, 1 current sensing input, and supports Modbus RTU or DNP3 RTU over D-Sub/RS-485, enabling reliable remote monitoring and control of feeder protection.
Yes. The EDR-3000-2A0GB1 is designed for feeder protection and metering, with compatible communication for SCADA integration, removable terminals for quick field maintenance, and a rugged mechanical design optimized for industrial environments.
Compliances are specified as ‘Contact Manufacturer’ for confirmation. When selecting for regulated environments, verify CE, UL, IP rating, and SIL compatibility with Eaton to ensure regional compliance and desired safety standards before deployment.
The four-input/four-output architecture, removable terminals, and conformal coating reduce maintenance time and replacement costs. RS-485 Modbus/DNP3 enables remote diagnostics, lowering on-site visits, while the warranty terms provide risk mitigation across the asset lifecycle.