Eaton EDR-3000-2A0IB0 Distribution Relay - RS-485
Part Number: EDR-3000-2A0IB0
Quick Summary
The Eaton distribution relay EDR-3000-2A0IB0 provides reliable feeder protection for industrial panels and control rooms. Engineers often struggle to integrate protection functions across multiple communication standards while maintaining uptime in demanding environments. Compliance details are provided by the manufacturer, and Eaton recommends confirming any SIL, CE, or IP ratings for your project; this model also features conformal coating for harsh environments. With 4 inputs and 4 removable terminals, it supports flexible feeder architectures, while the 19-300 Vdc / 40-250 Vac supply range accommodates diverse power schemes. The result is improved equipment uptime, simplified wiring, and scalable protection that aligns with modern plant architectures and remote monitoring needs.
Product Information
Extended Description
EDR-3000-2A0IB0 Eaton: Eaton distribution relay, EDR-3000, Distribution relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, over RS-485, over Ethernet RJ-45, Conformal Coated Circuit Boards, 19-300Vdc, 40-250Vac, 50/60 Hz
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2A0IB0
UPC
786679141878
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
1
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - EDR-3000-2A0IB0
Feature → Business Impact → Application: 4 inputs and 4 removable terminals simplify field wiring and reduce installation errors, lowering commissioning time and labor costs on panel feeders and feeder cubicles. This leads to faster deployment and ongoing maintenance efficiency in manufacturing lines and distribution panels. Feature → Business Impact → Application: Wide power supply range of 19-300 Vdc / 40-250 Vac supports diverse plant voltages, minimizing inventory needs and enabling cross-site deployments across substations and industrial facilities. Application: global plants with mixed voltages rely on a single protection device. Feature → Business Impact → Application: RS-485 Modbus RTU and Ethernet TCP (DNP3) connectivity enables remote monitoring and integration with plant-wide SCADA, improving diagnostics, fault analytics, and downtime reduction for feeders. Application: mid- to large-scale automation plants needing networked protection. Feature → Business Impact → Application: Conformal coating and rugged circuitry enhance reliability in dusty, humid, or temperature-variant environments, reducing field failures and service visits. Application: harsh factory floors, packaging lines, and outdoor enclosures. Feature → Business Impact → Application: 5 A and 1 A current sensing inputs with 4 inputs/4 outputs create compact, fully integrated protection and metering at the feeder level, lowering overall system complexity and enabling precise fault detection. Application: energy monitoring and protective relays in panel boards. Feature → Business Impact → Application: Semi-flush mounting and removable terminals streamline installation, facilitate retrofits, and improve serviceability in retrofit projects and new builds. Application: retrofits and new builds in commercial and industrial facilities.
Get a Quick Quote for a Eaton EDR-3000-2A0IB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-3000-2A0IB0?
Enquire Now
FAQs
When installing the EDR-3000-2A0IB0, plan for 4 removable terminals and semi-flush mounting to fit typical panel enclosures. Ensure the power supply is within 19-300 Vdc or 40-250 Vac and that wiring routes support current sensing inputs. The device is designed for feeder protection, so allocate space for easy access to connection points and potential future modular expansions.
The relay provides Modbus communication over RS-485 and DNP3 over Ethernet TCP, enabling remote monitoring and control from SCADA or historian systems. With 4 inputs and 4 outputs, it supports integrated protection logic and metering for feeder protection schemes, reducing the need for separate RTUs and simplifying network architecture.
Yes. Designed as a feeder distribution relay, it matches panel-based protection architectures with removable terminals for straightforward wiring, 50/60 Hz operation, and a broad voltage range. Its conformal coating enhances reliability in dusty or humid plant areas, making it suitable for typical manufacturing floors and substation panels.
The device is covered by Eaton’s warranty policy: one year from the date of installation or eighteen months from shipment, whichever comes first. For technical support, consult Eaton’s protective-relays documentation and the provided specification sheets, which include installation guidelines and compatibility notes for PowerPort-E and related tools.
Verify 4 inputs and 4 outputs, 19-300 Vdc / 40-250 Vac power range, and 50/60 Hz frequency. Confirm current sensing inputs of 1 A and 5 A, along with RS-485 Modbus and Ethernet TCP connectivity. Check that mounting is semi-flush and terminals are removable for ease of wiring, as well as ensuring conformal coating suitability for your environment.