Eaton EDR-3000-2A1BA0 Distribution Relay - 5A/1A

Part Number: EDR-3000-2A1BA0
Manufacturer
Eaton
Part number
EDR-3000-2A1BA0

Quick Summary

Eaton distribution relay EDR-3000-2A1BA0 provides robust feeder protection and monitoring for industrial power distribution. Engineers often struggle with coordinating protection settings across multiple feeders while maintaining reliable remote diagnostics. Compliance details are listed as 'Contact Manufacturer'—verify CE, SIL, or IP ratings directly with Eaton. This solution supports Modbus RTU or DNP3 RTU over RS-485, enabling scalable integration in modern automation networks, and pairs with 19-300Vdc or 40-250Vac power to streamline procurement. By combining flexible sensing with remote communication, it delivers business value through improved reliability, faster fault isolation, and reduced maintenance costs across plant-wide feeder protection.

Product Information

Extended Description

EDR-3000-2A1BA0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4,Feeder, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2A1BA0
UPC
786679142110
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
1
I/O options
Sensitive Ground Input
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Feature → Business Impact → Application: The EDR-3000-2A1BA0 supports a wide power supply range of 19-300Vdc and 40-250Vac with 50/60 Hz, simplifying installation across mixed power environments and reducing spare part inventories for feeders. This translates to faster commissioning and lower total cost of ownership in distributed power systems. Feature → Business Impact → Application: Communication over Modbus RTU or DNP3 RTU via RS-485 enables remote monitoring and SCADA integration, improving visibility into feeder performance and enabling proactive maintenance across multiple zones. This is essential for plants with centralized control rooms and remote substations. Feature → Business Impact → Application: Four inputs and four outputs with a single current sensing input and configurable Sensitive Ground Input provide precise protection and metering, supporting accurate coordination and fault analysis in complex feeder hierarchies. Feature → Business Impact → Application: Removable terminals and semi-flush mounting simplify field installation and replacements, minimizing downtime during upgrades and service calls in OEM installations and retrofit projects. Feature → Business Impact → Application: The device’s robust mechanical footprint and standard protection capabilities help ensure regulatory alignment and predictable performance, reducing compliance-related delays when deploying new feeder protection schemes in industrial facilities.

Get a Quick Quote for a Eaton EDR-3000-2A1BA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2A1BA0? Enquire Now

FAQs

Plan for semi-flush mounting with removable terminals to ease field wiring. Ensure power is supplied within the 19-300Vdc or 40-250Vac range and that RS-485 wiring supports Modbus RTU or DNP3 RTU communication for remote monitoring and SCADA integration.
The relay communicates over RS-485 using Modbus RTU or DNP3 RTU, enabling seamless data exchange for feeder status, metering, and protection events. This supports centralized monitoring and faster fault diagnosis across multiple feeders.
It offers current protection and metering with a single current sensing input and a 4/4 I/O configuration, allowing precise protection coordination across feeders and improved fault localization in industrial power networks.
Warranty follows Eaton policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. For technical support and certification details, consult Eaton directly to ensure all regulatory requirements are met.
Compliance is listed as 'Contact Manufacturer' on the data sheet. Verify CE, SIL, IP ratings, and any site-specific regulatory requirements directly with Eaton prior to deployment.