Eaton EDR-3000-2A1HA0 Distribution Relay - 61850/Mbus/DNP3 TCP
Part Number: EDR-3000-2A1HA0
Quick Summary
Distribution relay is a centralized feeder protection device used in industrial networks for reliable protection and monitoring. Operators face challenges integrating multiple communication protocols and maintaining spare parts consistency during upgrades. This model supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, aligning with modern SCADA ecosystems. Note: certification details such as CE marking, SIL ratings, or IP protection levels are not listed in the specification and should be confirmed with Eaton. The combination of broad power ranges, configurable I/O, and multi-protocol communications delivers tangible business value, including faster fault isolation, reduced commissioning time, and lower lifecycle costs for feeder protection projects.
Product Information
Extended Description
EDR-3000-2A1HA0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4,Feeder over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2A1HA0
UPC
786679141021
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
1
I/O options
Sensitive Ground Input
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
E-series protective relays
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - EDR-3000-2A1HA0
Broad power range and flexible I/O simplify panel design and field wiring, reducing inventory and installation time while supporting both 19-300 VDC and 40-250 VAC supply environments. This directly translates to cost savings and faster deployment in mixed-voltage facilities used in industrial automation and manufacturing. Multi-protocol communication with 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet enables seamless SCADA integration, data-driven protection tuning, and centralized monitoring across distributed feeders, reducing engineering effort and potential interoperability gaps. The unit includes 1 current sensing input and 4 inputs/4 outputs, enabling precise current protection and metering while maintaining compact footprint—ideal for control cabinets with space constraints. Removable terminals and semi-flush mounting simplify installation and servicing, improving reliability in tight panel layouts and retrofit projects. A Sensitive Ground Input option supports robust grounding practices, and the 50/60 Hz frequency rating ensures compatibility with global power systems, helping facilities standardize protection across plants and substations. Warranty (1 year from installation or 18 months from shipment) adds lifecycle assurance for procurement and maintenance planning.
Get a Quick Quote for a Eaton EDR-3000-2A1HA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-3000-2A1HA0?
Enquire Now
FAQs
Begin with confirming the semi-flush mounting footprint and removable terminals for easy field wiring. Connect the power supply within the 19-300 Vdc or 40-250 Vac range, then wire the four inputs and four outputs according to the control scheme. Finally, configure the communication channels (61850, M-Bus TCP, DNP3 TCP/UDP over Ethernet) to your SCADA or protection system and verify protection settings using the PowerPort-E or equivalent configurator.
The EDR-3000 supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45, enabling multi-protocol integration with modern SCADA and protection networks. This supports scalable feeder protection and metering while minimizing engineering effort during integration and commissioning.
Yes. The device is rated for 50/60 Hz operation and supports dual voltage inputs (19-300 VDC and 40-250 VAC), making it suitable for both utility-scale feeders and industrial automation environments with mixed power systems.
The EDR-3000-2A1HA0 carries Eaton’s standard warranty: one year from installation or eighteen months from shipment, whichever occurs first. For detailed coverage, service options, and parts availability, consult Eaton or an authorized distributor to ensure alignment with site maintenance plans.
With four inputs and four outputs, current protection and metering capabilities, and multi-protocol communications, the EDR-3000 enables accurate protection tuning, real-time monitoring, and easy integration into SCADA systems. This reduces fault downtime, supports regulatory compliance, and lowers total cost of ownership for feeder protection projects.