Quick Summary

Eaton distribution relay EDR-3000-2B0EB0 provides robust feeder protection for industrial control panels. Engineers often struggle with reliable communication and fault isolation when expanding Profibus networks, especially in harsh environments. Certification details are provided by the manufacturer, with typical industry practice referencing CE, IP, and SIL standards to ensure safe and compliant operation; confirm applicability for this model in the official Eaton datasheet. This device supports Profibus-DP over D-Sub / RS-485 and a versatile power range of 19-300 VDC or 40-250 VAC, enabling flexible integration into modern automation schemas. The combination of 8 inputs and 6 outputs, along with a conformal coating option, translates into improved uptime and easier maintenance for industrial feeders.

Product Information

Extended Description

EDR-3000-2B0EB0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 6,Feeder, over D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2B0EB0
UPC
786679141663
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
1
I/O options
Trip Coil Monitor
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
8
Number of outputs
6
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Power flexibility is a practical advantage of the EDR-3000-2B0EB0. With a power supply range of 19-300 VDC and 40-250 VAC, this relay can be installed across a wide spectrum of motor loads and control circuits without extra adapters. The 8 inputs and 6 outputs deliver ample I/O for feeder protection schemes, helping engineers consolidate panels and reduce wiring complexity. This configuration supports efficient commissioning, lowers stocking costs, and accelerates changes in evolving automation layouts in manufacturing and process plants. Profibus-DP over D-Sub/RS-485 provides robust, industry-standard communication between the relay and master controllers. The result is faster fault diagnosis, better visibility of feeder conditions, and simpler remote updates during runtime. In practice, integrators leverage this capability to implement zone-selective interlocking and more precise protection coordination. This background connectivity also enhances diagnostics in machine cells and packaging lines, where downtime has a direct impact on throughput and service-level targets. Installation practicality is enhanced by semi-flush mounting and removable terminals, which streamline field wiring, testing, and future upgrades. The conformal coating option protects circuit boards in challenging environments, including dust, humidity, and temperature swings common in industrial facilities. Together, these features translate to shorter commissioning windows, easier maintenance, and greater system resilience when adding feeders to existing automation architectures. Warranty and compatibility support long-term value. Eaton offers a one-year warranty from installation or 18 months from shipment, to help protect capital investments. The EDR-3000-2B0EB0 integrates with a base relay (EDR-3000), 1 current-sensing input, and Trip Coil Monitor options, ensuring coherent protection schemes over Profibus-DP networks. This design provides a scalable, maintenance-friendly feeder solution that aligns with efficiency goals and reduces lifecycle costs in industrial facilities.

Get a Quick Quote for a Eaton EDR-3000-2B0EB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2B0EB0? Enquire Now

FAQs

The EDR-3000-2B0EB0 uses removable terminals and a semi-flush mounting method, enabling straightforward field wiring and fast integration into feeder protection schemes. Verify the 19-300 VDC / 40-250 VAC power range, connect Profibus-DP over RS-485 to the master controller, and ensure the 8 inputs / 6 outputs align with your protective relays. Refer to the Eaton datasheet for wiring diagrams and the E-series protective relays brochure for step-by-step guidance.
Key specs include a power supply range of 19-300 VDC and 40-250 VAC, 50/60 Hz operation, phase current options of 5A and 1A, and a current-sensing input count of 1. The device features 8 physical inputs and 6 outputs, with Profibus-DP communication via D-Sub/RS-485. Confirm the compatibility of these values with your protective scheme and panel design before commissioning.
Yes. The 8-input, 6-output configuration, coupled with Profibus-DP over RS-485, supports robust feeder protection and diagnostics essential in manufacturing lines. Its broad power range and conformal coating option help integrate into varied machine centers while maintaining reliability. The device is designed to protect feeders with clear fault indication and remote communication capabilities, reducing downtime and enabling faster maintenance cycles.
The data indicates Compliances: Contact Manufacturer, and the warranty follows Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. For formal certifications (CE, IP, SIL) and any regulatory declarations, consult Eaton’s official datasheet and warranty documentation to confirm applicability to your installation and regional requirements.
Official specifications and programming resources are available on Eaton’s site. Key assets include the E-series protective relays brochure, the EDR-3000-2B0EB0 specification sheet, and multiple programming videos. These resources cover installation, configuration, wiring, and diagnostic practices to maximize uptime and ensure correct Profibus-DP integration.