Eaton EDR-3000-2B0IB0 Distribution Relay - Trip Coil Monitor
Part Number: EDR-3000-2B0IB0
Quick Summary
Eaton distribution relay enables feeder protection by monitoring currents and coordinating trips for electrical feeders in industrial plants. Engineers often face nuisance trips and downtime when protection is poorly coordinated, and this device addresses that by delivering precise current sensing and configurable trip logic. Explicit certifications such as CE, SIL or IP ratings aren’t listed in this data; verify with Eaton’s specification sheets for compliance and installation requirements. With RS-485 Modbus/DNP3 and Ethernet TCP/IP connectivity, it supports remote monitoring, data collection, and integration with modern automation networks, helping tighten protection and reduce maintenance costs.
Product Information
Extended Description
EDR-3000-2B0IB0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 6, Removable, Feeder, over RS-485, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2B0IB0
UPC
786679142134
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
1
I/O options
Trip Coil Monitor
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
8
Number of outputs
6
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - EDR-3000-2B0IB0
Wide power range and removable terminals reduce engineering time and field wiring errors, enabling faster panel builds and easier maintenance in harsh environments, ideal for feeder protection in industrial plants. This translates to lower lifecycle costs and improved uptime as servicing can be performed without specialized tooling. The device’s 5A/1A phase current sensing and current protection and metering capabilities provide precise coordination across protected zones, improving selectivity and minimizing nuisance trips in complex motor and feeder networks. RS-485 and Ethernet TCP/IP communications (Modbus/DNP3 RTU/TCP) streamline SCADA/DCS integration, enabling remote diagnostics, trend analysis, and faster fault isolation. Compatibility with the base EDR-3000 relay family and removable I/O terminals simplifies upgrades and spare-part logistics for maintenance teams. Conformal coating and semi-flush mounting support installation in challenging environments while reducing moisture and dust ingress.
Get a Quick Quote for a Eaton EDR-3000-2B0IB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-3000-2B0IB0?
Enquire Now
FAQs
Begin by confirming the panel accommodates a semi-flush mounting device with removable terminals. Mount the EDR-3000-2B0IB0 securely, connect the 8 inputs and 6 outputs per the feeder layout, and wire the power supply within the 19-300Vdc or 40-250Vac range. Use RS-485 for Modbus/DNP3 RTU and Ethernet for TCP/IP remote communications. After wiring, perform a factory-default reset, apply protection settings, and verify communication with the SCADA or HMI system to ensure correct trip coordination.
The EDR-3000-2B0IB0 provides phase current sensing at 5A and 1A, with 8 inputs and 6 outputs. It supports a dual voltage range of 19-300V DC and 40-250V AC, operating at 50/60 Hz. The unit includes current protection and metering capabilities and offers a Trip Coil Monitor option. Removable terminals simplify field maintenance, and the conformal coating improves reliability in challenging environments.
Yes. The EDR-3000-2B0IB0 supports Modbus/DNP3 RTU over RS-485 and Modbus/DNP3 TCP over Ethernet, enabling seamless integration with existing SCADA or DCS networks. This connectivity supports remote monitoring, data logging, and coordinated protection schemes across multiple feeders. For optimal results, configure addressing, baud rate, and register mapping according to your SCADA platform and Eaton’s datasheet guidance.
The provided data lists Compliances as Contact Manufacturer, with no explicit CE, SIL, or IP ratings. For formal certification details, consult Eaton’s specification sheets or contact Eaton directly to confirm applicable standards for your region and installation. When planning compliance, verify wiring, enclosures, environmental ratings, and any site-specific electrical codes that apply to your facility.
Deploying the EDR-3000-2B0IB0 can reduce downtime through improved protection selectivity and faster fault isolation, thanks to precise current sensing and robust communications. Removable terminals simplify routine maintenance and field servicing, while Ethernet/RS-485 connectivity enables remote diagnostics and trend analysis, reducing on-site visits. The wide input range and conformal coating improve reliability in harsh environments, contributing to lower lifecycle costs and a faster return on investment.