Eaton EDR-3000-2B1FA0 Distribution Relay - Fiber Modbus

Part Number: EDR-3000-2B1FA0
Manufacturer
Eaton
Part number
EDR-3000-2B1FA0

Quick Summary

Eaton distribution relay is a reliable feeder protection device designed for industrial plants. It helps prevent outages by delivering precise fault detection and coordinated tripping across feeder circuits, reducing unplanned downtime. Typical industry practices seek CE, UL, and robust IP ratings; always verify the specific certifications for this model with Eaton to ensure compliance in your region. By supporting Modbus RTU or DNP3 RTU over fiber, this relay enables secure, remote SCADA communication while operating over a wide power range. This combination delivers measurable business value through improved reliability, faster fault isolation, and streamlined maintenance in modern automation environments.

Product Information

Extended Description

EDR-3000-2B1FA0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU , 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 6,Feeder, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,Trip Coil Monitor
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2B1FA0
UPC
786679141069
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over Fiber Optic ST
Current sensing inputs
1
I/O options
Sensitive Ground Input Trip Coil Monitor
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
8
Number of outputs
6
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Flexible power range and robust communication enable installation across diverse plant environments, minimizing wiring diversity and improving commissioning speed. Feature → Business Impact → Application: Wide power supply range of 19-300 Vdc and 40-250 Vac supports both legacy and new equipment, reducing inventory and simplifying upgrades on feeder networks. Feature → Business Impact → Application: Eight inputs and six outputs provide scalable signaling and control, enabling precise feeder protection and status indication without extra hardware. Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over fiber optic ST delivers secure, noise-immune remote communication to SCADA, improving visibility and reducing troubleshooting time. Feature → Business Impact → Application: Sensitive Ground Input and Trip Coil Monitor enhance fault detection and safety margins, supporting compliance in safety-critical applications. Feature → Business Impact → Application: Semi-flush mounting with removable terminals reduces installation time and simplifies field service, lowering total cost of ownership. Industry context notes: these capabilities align with modern feeder protection needs in utilities and heavy industries, while ensuring compatibility with Eaton’s E-series relay ecosystem and MTU/SCADA integrations.

Get a Quick Quote for a Eaton EDR-3000-2B1FA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2B1FA0? Enquire Now

FAQs

To install the EDR-3000-2B1FA0 with fiber optic communication, mount the unit for semi-flush operation in a suitable enclosure, route the fiber optic ST connection to the Modbus/DNP3 RTU interface, and connect the 19-300 Vdc or 40-250 Vac power supply as specified. Use the removable terminals for quick field wiring, verify ground continuity with the Sensitive Ground Input, and configure the Modbus/DNP3 address and baud rate to match the PLC or SCADA system. Proper fiber termination and shielding minimize EMI, enhancing reliability in noisy plant environments.
Key specifications include a dual power supply range of 19-300 Vdc and 40-250 Vac, 50/60 Hz operation, 8 inputs and 6 outputs, and phase current options of 5A and 1A. These values enable flexible deployment across different feeder configurations and ensure compatibility with both older control circuits and modern digital protection schemes. The ability to monitor current protection and metering supports accurate fault detection, while the Modbus RTU or DNP3 RTU over fiber provides robust remote communication essential for centralized protection schemes.
This model specifies general compliance as 'Contact Manufacturer' for formal certifications, so verify with Eaton for CE, UL, IP ratings, and any industry-specific requirements before deployment. In practice, confirm enclosure rating, environmental limits, and installation practices with your QA team. The device’s grounding and insulation features, including its Sensitive Ground Input, contribute to safe operation, but final certification alignment should be documented in your project specs to meet regulatory and customer expectations.
Key ROI drivers include reduced wiring complexity from a single 8-input/6-output module, simplified maintenance due to removable terminals, and faster commissioning from semi-flush mounting. The fiber-based Modbus/DNP3 link minimizes electrical noise impact on communications, cutting downtime during fault events. Additionally, wide power compatibility supports retrofits without major power system changes, offering extended service life and lower total cost of ownership in feeder protection projects.
The EDR-3000-2B1FA0 is designed for feeder protection with Modbus RTU or DNP3 RTU communication over fiber, enabling integration with SCADA and protection panels. While specific SIL ratings and zone selective interlocking (ZSI) values should be verified with Eaton, the unit supports current protection and metering inputs and provides trip monitoring through the configurable outputs. For robust protection schemes, ensure compatibility with your PLC's I/O mapping and use the built-in communication channels to coordinate tripping signals and alarm reporting across the plant.