Eaton EDR-3000-2B1GA1 Distribution Relay – Modbus RTU over RS-485

Part Number: EDR-3000-2B1GA1
Manufacturer
Eaton
Part number
EDR-3000-2B1GA1

Quick Summary

Eaton distribution relay EDR-3000-2B1GA1 provides robust feeder protection and control for industrial electrical panels. This device helps engineers streamline wiring and improve reliability across mixed-voltage environments. A major challenge in modern facilities is integrating diverse power supplies and fieldbus protocols within a single feeder, which this relay addresses with a broad power range and RS-485 communication supporting Modbus RTU or DNP3 RTU. While exact compliance certifications should be confirmed with the manufacturer, equipment in this class typically aligns with recognized industry standards to simplify procurement and approval processes. By combining 8 inputs, 6 outputs, and flexible mounting, the EDR-3000-2B1GA1 delivers fast deployment and clear long-term value for feeder protection and metering applications.

Product Information

Extended Description

EDR-3000-2B1GA1 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 6,Feeder D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2B1GA1
UPC
786679141175
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
8
Number of outputs
6
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
0
Wide power supply range enables installation across global sites without additional power conversion, reducing wiring complexity and inventory needs. Business impact: lower capex and faster commissioning for multi-site feeders. Application: industrial plants with 19-300 Vdc or 40-250 Vac supplies. The device supports Modbus RTU or DNP3 RTU over RS-485, enabling seamless SCADA integration and centralized protection coordination. Business impact: tighter control, improved outage analysis, and easier firmware updates. Application: feeder protection linked to PLCs and energy management systems. With 8 inputs and 6 outputs plus 1 current-sensing input and 5 A/1 A phase currents, operators gain granular protection and metering without additional equipment. Business impact: enhanced visibility and faster fault isolation. Application: current protection and meter-ready feeder schemes. Mounting is projected with removable terminals, simplifying field wiring, testing, and future swaps. Business impact: reduced labor costs and downtime. Application: maintenance windows and spare-part planning. The I/O options include Trip Coil Monitor and Sensitive Ground Input, supporting advanced fault signaling and enhanced safety. Business impact: improved fault discrimination and personnel protection. Application: high-risk industrial feeders and critical power paths.

Get a Quick Quote for a Eaton EDR-3000-2B1GA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2B1GA1? Enquire Now

FAQs

Install with the included projection mounting and removable terminals for quick wiring. Connect 8 inputs and 6 outputs to your feeder circuit, then interface the RS-485 port using Modbus RTU or DNP3 RTU over a D-Sub connector. Ensure your power supply is within 19-300 Vdc or 40-250 Vac and that your SCADA system supports the chosen protocol. Verify wiring integrity and perform a commissioning test to confirm communication and protection settings.
The device supports wide input ranges including 19-300 Vdc and 40-250 Vac, operates at 50/60 Hz, and provides phase current options of 5 A and 1 A. It features one current-sensing input and multiple I/O for protection and metering, enabling precise fault detection and measurement within feeder circuits.
Yes, the relay is designed for feeder protection in industrial panels, with fieldbus communication options that ease integration with protection schemes. However, exact certifications should be confirmed with Eaton for your environment, as specifications show manufacturer-listed compliance rather than a published certification mark.
Certification details are provided by the manufacturer. The product listing notes Compliance as ‘Contact Manufacturer,’ so verify CE, UL, IP ratings, or other certifications directly with Eaton prior to deployment to ensure alignment with local regulations and plant standards.
The unit uses removable terminals for ease of wiring and replacement, reducing downtime during maintenance. Its 8-in/6-out configuration with a compact 5.3 lb footprint supports faster assembly and service, while its wide power range and RS-485 communications reduce integration costs and improve protection reliability, contributing to a favorable return on investment over the equipment’s life cycle.