Eaton EDR-3000-2B1GB0 Distribution Relay - RS485 Modbus/DNP3

Part Number: EDR-3000-2B1GB0
Manufacturer
Eaton
Part number
EDR-3000-2B1GB0

Quick Summary

The Eaton distribution relay EDR-3000 provides reliable feeder protection for industrial electrical systems. Engineers often struggle to integrate multiple inputs and ensure robust RS-485 communications across Modbus RTU or DNP3 RTU networks. Certification details are not listed here; consult Eaton for CE, SIL, and IP ratings relevant to your region and configuration. With 8 inputs and 6 outputs, a wide power range (19-300 Vdc / 40-250 Vac), and conformal-coated circuitry, it streamlines installation and enhances field performance. The unit supports sensitive ground input options, seamless mounting, and straightforward diagnostics, delivering measurable business value through uptime, reduced fault clearance times, and easier compliance with feeder protection standards.

Product Information

Extended Description

EDR-3000-2B1GB0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 6,Feeder, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2B1GB0
UPC
786679141182
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
Sensitive Ground Input Trip Coil Monitor
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
8
Number of outputs
6
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Modbus RTU or DNP3 RTU over D-Sub RS-485 is supported, enabling straightforward integration with existing SCADA and historian systems. This translates to faster configuration, centralized monitoring, and quicker fault isolation in feeder protection schemes. Power supply range of 19-300 Vdc or 40-250 Vac lets the unit operate across diverse plant power architectures without additional transformers. In practice, this reduces wiring complexity and stock requirements while supporting 50/60 Hz operation. The 8 inputs and 6 outputs, along with a single current sensing input, provide flexible control and protection sequencing for complex feeder layouts. I/O options such as Sensitive Ground Input and Trip Coil Monitor enhance safety and fault diagnostics, while conformal coating and removable terminals simplify field servicing. Semi-flush mounting and the 7.49 in x 8.62 in x 6.82 in enclosure size balance ruggedness with install convenience. Phase current options of 5A and 1A enable precise protection coordination across multi-feeder configurations, contributing to lower fault loss and faster restoration.

Get a Quick Quote for a Eaton EDR-3000-2B1GB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2B1GB0? Enquire Now

FAQs

Begin by mounting the device in a semi-flush enclosure and securing the removable terminals for easy field maintenance. Connect the eight inputs and six outputs according to the feeder protection scheme, and route the Modbus RTU or DNP3 RTU RS-485 communication lines (D-Sub) to the control system. Ensure the power supply is within 19-300 VDC or 40-250 VAC and that the system frequency is 50/60 Hz. Verify the Sensitive Ground Input and Trip Coil Monitor configurations during commissioning to ensure accurate fault sensing and safe operation.
The EDR-3000-2B1GB0 supports Modbus RTU or DNP3 RTU over D-Sub RS-485, enabling direct integration with common SCADA and protection schemes. With 8 inputs and 6 outputs, you can align I/O to existing feeder protection logic and trigger appropriate trips or alarms. The removable terminals simplify wiring changes during upgrades, and the conformal-coated circuitry enhances reliability in industrial environments.
Yes. The unit operates at 50/60 Hz and accepts a wide power range of 19-300 VDC or 40-250 VAC, allowing compatibility across different plant power systems. This flexibility helps reduce transformer needs and simplifies retrofits. Ensure the chosen voltage matches the control power requirements for consistent protection and accurate metering across feeders.
Certification details are not specified in the provided data. For CE, SIL, or IP ratings, consult Eaton or your regional distributor to confirm the exact certifications applicable to your installation, configuration, and jurisdiction. It’s common for protection relays to require region-specific approvals, so obtaining formal confirmation is recommended before procurement.
Deploying the EDR-3000-2B1GB0 can reduce downtime through faster fault isolation and centralized monitoring via RS-485 communications, lowering unplanned outage durations. The conformal coating and removable terminals simplify field maintenance, while the wide input range minimizes wiring changes during upgrades. With a one-year warranty (or 18 months from shipment, whichever occurs first), you gain predictable support and lower lifecycle costs as part of a broader protection strategy.