Eaton distribution relay EDR-3000-2B1HA1 - 61850

Part Number: EDR-3000-2B1HA1
Manufacturer
Eaton
Part number
EDR-3000-2B1HA1

Quick Summary

Eaton distribution relay EDR-3000-2B1HA1 provides feeder monitoring and Ethernet-enabled control for industrial power networks. Users often struggle to integrate protection relays into modern SCADA and IEC 61850 or DNP3 architectures, leading to slow commissioning. Certification specifics are not listed in the provided data; however the device communicates via IEC 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet, aligning with common industry practices. With a broad power-supply range and flexible I/O, it enables scalable protection schemes and faster, safer plant operation.

Product Information

Extended Description

EDR-3000-2B1HA1 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 6,Feeder over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2B1HA1
UPC
786679141328
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
1
I/O options
Sensitive Ground Input Trip Coil Monitor
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
8
Number of outputs
6
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
0
Feature: Flexible power inputs and robust I/O. Benefit: Supports 19-300Vdc and 40-250Vac, 8 inputs and 6 outputs, enabling mixed AC/DC feeder protection without additional modules. Application: Feeder protection in mixed electrical networks, improving commissioning speed and reducing wiring errors. Feature: Ethernet-based communication with IEC 61850, M-Bus TCP, and DNP3 TCP/UDP. Benefit: Enables remote configuration, centralized monitoring, and interoperability across modern SCADA environments. Application: Substation and industrial plant integration with common protocol stacks, lowering integration risk. Feature: Projection mounting and removable terminals. Benefit: Simplifies installation and maintenance in constrained spaces while ensuring reliable field wiring. Application: Control cabinets and switchgear assemblies where quick serviceability matters. Feature: 5 A/1 A current sensing inputs and 8/6 I/O. Benefit: Supports detailed protection schemes and precise metering without expanding the footprint. Application: Modern feeder protection with accurate sensing and status reporting. Feature: Wide power range 19-300Vdc / 40-250Vac and 50/60 Hz operation. Benefit: Facilitates universal deployment across global facilities, reducing SKU fragmentation. Application: Worldwide rollout in diverse industrial environments.

Get a Quick Quote for a Eaton EDR-3000-2B1HA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2B1HA1? Enquire Now

FAQs

The EDR-3000-2B1HA1 is designed for projection mounting with removable terminals, streamlining wiring and field maintenance. It supports a wide power range of 19-300 VDC or 40-250 VAC and provides 8 inputs along with 6 outputs, making it suitable for compact control panels and panelboard integrations in feeder protection schemes.
The relay communicates over IEC 61850, M-Bus TCP, and DNP3 TCP/UDP via Ethernet RJ45, enabling seamless integration with modern SCADA systems. This supports remote configuration, status monitoring, and interoperability with standard substation and industrial automation architectures.
Yes. With 8 inputs and 6 outputs, current sensing options at 5 A and 1 A, projection mounting, and a flexible power supply (19-300 VDC, 40-250 VAC), the device is well-suited for feeder protection in substations and automated plant feeder networks, offering reliable protection logic and monitoring visibility.
The provided data does not list specific certifications such as CE, UL, IP ratings or SIL. For regulatory compliance details and field approvals, contact Eaton directly. The device does support industry-standard communication protocols (IEC 61850, M-Bus TCP, DNP3), which aligns with common compliance expectations in industrial automation.
The relay enables faster commissioning through remote configuration and centralized monitoring via Ethernet communications, reducing on-site testing time and downtime. Its flexible I/O and wide power range support scalable protection schemes, lowering spare-part costs and enabling a smoother migration to IEC 61850/DNP3-based architectures, delivering measurable uptime and maintenance efficiency gains.