Eaton distribution relay EDR-3000-2B1IA0 - RS-485 & Ethernet enabled

Part Number: EDR-3000-2B1IA0
Manufacturer
Eaton
Part number
EDR-3000-2B1IA0

Quick Summary

Eaton distribution relay EDR-3000-2B1IA0 is a robust feeder protection device designed for industrial power distribution and remote monitoring. In modern plants, engineers face challenges coordinating protection, metering, and communications across multiple feeders with legacy solutions. Compliance details are defined by the manufacturer; for certifications such as CE, SIL, or IP ratings, refer to Eaton's official documentation. This relay offers RS-485 Modbus RTU and Ethernet TCP connectivity, 8 inputs and 6 outputs, and current-sensing capabilities that support scalable protection and metering. With wide power ranges and modular I/O options, it enables streamlined procurement and consistent performance across global installations, delivering measurable business value through improved reliability and data-driven decision-making.

Product Information

Extended Description

EDR-3000-2B1IA0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 6,Feeder, over RS-485, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2B1IA0
UPC
786679141342
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Current sensing inputs
1
I/O options
Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
8
Number of outputs
6
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Feature: Wide power supply range and flexible mounting. Benefit: Reduces the need for multiple part variants and simplifies global deployment, lowering inventory and installation time. Application: Ideal for feeders in diverse electrical systems that require 19-300 Vdc or 40-250 Vac operation with semi-flush mounting for space-constrained panels. Feature: 8 inputs and 6 outputs with removable terminals. Benefit: Scalable control and straightforward wiring; supports complex feeder logic and quick field maintenance. Application: Feeder protection schemes in switchgear and panelboards where clear I/O mapping improves reliability and fault isolation. Feature: Communications integration via RS-485 Modbus RTU and Ethernet TCP (RJ-45). Benefit: Seamless SCADA interoperability, remote diagnostics, and centralized data collection, reducing on-site visits. Application: Industrial plants deploying unified monitoring across multiple feeders. Feature: Current protection and metering with up to 5 A and 1 A phase currents. Benefit: Precise fault detection and energy measurement enabling better demand management and outage reduction. Application: Load protection and energy reporting for critical feeders. Feature: Trip Coil Monitor and Sensitive Ground Input. Benefit: Enhanced protective coordination and safer fault clearance with robust fault indication. Application: Critical protection schemes in substations and high-availability panel assemblies. Feature: Semi-flush mounting and removable terminals. Benefit: Faster installation, easier maintenance, and reliable terminal connections in tight spaces. Application: Retrofits and new builds where installation efficiency matters. Note: Compliance details are defined by the manufacturer; for certifications such as CE, SIL, or IP ratings, refer to Eaton's official documentation. Industry context: As part of Eaton’s E-Series, this distribution relay aligns with modern feeder protection needs, supports interoperability with common industrial protocols, and provides a solid foundation for digitalized protective relays in smart plants.

Get a Quick Quote for a Eaton EDR-3000-2B1IA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2B1IA0? Enquire Now

FAQs

Install the EDR-3000-2B1IA0 using its semi-flush mounting and removable terminals to simplify wiring in existing switchgear. Connect 8 inputs and 6 outputs as required by your feeder protection scheme, and integrate RS-485 Modbus RTU or Ethernet TCP for SCADA communication. Verify power supply within 19-300Vdc or 40-250Vac, and use the Trip Coil Monitor and Sensitive Ground Input for enhanced fault indication.
Key specs include a power supply range of 19-300 Vdc and 40-250 Vac, 50/60 Hz operation, 8 inputs and 6 outputs, and phase current ratings of 5A and 1A. It supports current protection and metering, with I/O options including Trip Coil Monitor and Sensitive Ground Input, enabling precise protection and monitoring of feeder circuits.
Yes. The device provides Modbus communications over RS-485 (RTU) and Modbus TCP over Ethernet RJ-45, enabling straightforward integration with existing SCADA systems and centralized data logging. This dual-channel capability supports reliable remote monitoring and faster fault diagnosis across multiple feeders.
Compliances are defined by the manufacturer; refer to Eaton’s official documentation for definitive CE, IP, or SIL statuses. If your project requires specific certifications, consult Eaton’s specification sheets or contact Eaton support to confirm the exact certifications for your region and application.
The EDR-3000-2B1IA0 enables improved protection selectivity and faster fault isolation, reducing outage duration. Remote monitoring via RS-485 and Ethernet reduces site visits and enables predictive maintenance through SCADA data, lowering operating costs and improving system reliability over the life of the feeder network.