Eaton EDR-3000-2B1LA1 Distribution Relay - Mbus TCP / DNP3

Part Number: EDR-3000-2B1LA1
Manufacturer
Eaton
Part number
EDR-3000-2B1LA1

Quick Summary

The Eaton EDR-3000-2B1LA1 distribution relay provides robust feeder protection for industrial electrical networks. Engineers often face protocol fragmentation and downtime, which can complicate monitoring and response times. Certification details vary by region; verify CE safety marks, SIL risk reduction levels, and IP ratings with Eaton to ensure regulatory compliance for your site. The device combines wide power options with flexible I/O and open communications, delivering a scalable solution for modern automation projects. By integrating Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Ethernet, it enables reliable, remote visibility and quicker fault isolation across distributed systems, helping control rooms maintain uptime and safety.

Product Information

Extended Description

EDR-3000-2B1LA1 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 6,Feeder, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2B1LA1
UPC
786679142479
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
1
I/O options
Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
0
Number of inputs
8
Number of outputs
6
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
0
Wide power supply range from 19-300 Vdc and 40-250 Vac gives you a single-sourcing approach across plants with mixed voltages, reducing spare-part inventory and simplifying procurement for feeder protection projects. This translates to lower maintenance costs and faster commissioning, especially in multi-site operations where uniform protection schemes are critical. 8 inputs and 6 outputs, with current sensing inputs and configurable I/O options including Trip Coil Monitor and Sensitive Ground Input, enable precise protection logic and rapid fault isolation for critical feeders in manufacturing and data-center environments. The Mbus TCP or DNP3 TCP/UDP over LC duplex fiber Enet communications capability delivers seamless SCADA integration and remote monitoring, improving diagnostic speed and plant-wide visibility without sacrificing security. Projection mounting and removable terminals ease retrofits and panel installations, reducing field labor time and enabling reversible upgrades in existing switchgear cabinets. Overall, the EDR-3000-2B1LA1 supports scalable protection architectures, lower lifecycle costs, and better compliance with modern industrial networking standards like Modbus and DNP3.

Get a Quick Quote for a Eaton EDR-3000-2B1LA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2B1LA1? Enquire Now

FAQs

Begin with the projection mounting approach and ensure the unit fits within the designated panel space. Use the removable terminals for straightforward wiring and verify the 19-300 Vdc / 40-250 Vac power range for your plant’s supply. Confirm compatible communication protocols (Mbus TCP or DNP3 TCP/UDP over LC fiber) and ensure your SCADA system supports these interfaces for seamless integration.
The relay supports a wide power range of 19-300 Vdc and 40-250 Vac at 50/60 Hz. It provides 5 A and 1 A phase current options, with 8 inputs and 6 outputs. Current sensing inputs are available (one input), and the device is designed for feeder protection with current protection and metering capabilities.
Ideal for industrial feeders requiring remote monitoring and integrated SCADA communication. Its Mbus TCP and DNP3 TCP/UDP over LC duplex fiber Ethernet enable reliable data exchange with control rooms, while the 8/6 I/O configuration supports complex protection schemes, fault isolation, and coordinated control across distributed substations and manufacturing lines.
Certification details are provided by the manufacturer. Verify CE marking, applicable safety approvals, and any regional SIL or IP-related requirements with Eaton before deployment to ensure regulatory compliance for your site.
Expect reduced downtime through improved remote monitoring and faster fault isolation via SCADA integration. The removable terminals and projection mounting simplify field servicing, while the wide input range lowers spare-part variety. Warranty details follow Eaton’s policy (one year from installation or 18 months from shipment), contributing to predictable lifecycle budgeting.