Eaton EDR-3000-2C0BA0 Distribution Relay - RS485 Modbus/DNP3

Part Number: EDR-3000-2C0BA0
Manufacturer
Eaton
Part number
EDR-3000-2C0BA0

Quick Summary

Eaton distribution relay EDR-3000-2C0BA0 provides feeder protection and metering for industrial power systems. Engineers often struggle with integrating protective relays into SCADA, achieving reliable communication, and reducing complex wiring. Compliance details (CE, SIL, IP) vary by region; consult the Eaton datasheet for exact approvals. In practice, this model delivers flexible power input options and remote communication to streamline protection schemes, enable scalable monitoring, and minimize panel clutter. With Modbus RTU or DNP3 RTU over RS485 and removable terminals, it supports quick commissioning while preserving future expansion for feeder protection and metering applications.

Product Information

Extended Description

EDR-3000-2C0BA0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz ,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C0BA0
UPC
786679142592
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
1
I/O options
IRIG-B
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Feature: Wide power supply range supporting 19-300 Vdc and 40-250 Vac enables use across diverse panels and plants. Business Impact: Reduces inventory and simplifies procurement while ensuring reliable operation across regional power environments. Application: Feeder protection in mixed-voltage facilities. Feature: Communication over RS485 with Modbus RTU or DNP3 RTU enables seamless SCADA integration. Business Impact: Improves remote diagnostics, fault reporting, and sequence control, cutting maintenance time. Application: Substation feeder monitoring and centralized protection. Feature: 4 inputs and 4 removable outputs streamline wiring and allow easy retrofits or upgrades. Business Impact: Lowers installation cost and downtime during upgrades. Application: Replacement of legacy relays with modern protection logic. Feature: Current sensing inputs at 1 and phase currents of 5A/1A deliver precise protection coordination. Business Impact: Enhances selectivity and reduces nuisance trips, protecting equipment lifespan. Application: High-speed protection and metering of feeders. Feature: Zone selective interlocking (1) improves fault isolation speed. Business Impact: Minimizes outage duration and equipment stress during faults. Application: Safe, rapid clearance in switchgear assemblies. Feature: Flexible mounting (semi-flush) and removable terminals simplify installation and service. Business Impact: Faster commissioning and easier field maintenance. Application: New builds and panel upgrades. Feature: Time synchronization option (IRIG-B) and general compliance notes. Business Impact: Enables synchronized operations in complex protection schemes. Application: Utilities and large plants with time-critical protection needs.

Get a Quick Quote for a Eaton EDR-3000-2C0BA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2C0BA0? Enquire Now

FAQs

Begin by selecting a suitable panel location and mounting the unit with its semi-flush mounting method. Use the removable terminals to connect four inputs and four outputs, ensuring secure 19-300 Vdc or 40-250 Vac power. Configure communication lines to your SCADA system via RS485 using Modbus RTU or DNP3 RTU, and verify I/O wiring against the datasheet. IRIG-B timing can be added as an option if precise time-synchronization is required for coordinated protection. This setup minimizes wiring complexity while ensuring robust protection signaling and metering data flow.
Confirm power supply compatibility (19-300 Vdc or 40-250 Vac, 50/60 Hz) and ensure the device is wired to appropriate sensing inputs. The relay supports current sensing inputs and provides phase current options of 5A and 1A for accurate protection coordination. With RS485 communication, you can run Modbus RTU or DNP3 RTU for telemetry and control. The 4x4 I/O configuration supports flexible protection logic and metering, helping to meet protection standards while reducing mis-trips.
Yes. Designed for feeder protection with current protection and metering capabilities, it supports zone selective interlocking and remote monitoring via RS485 communication. Its flexible power input, removable terminals, and 4-in/4-out I/O configuration simplify integration into existing switchgear and feeders. This makes it a strong fit for industrial plants seeking reliable protection, improved fault isolation, and scalable protection schemes.
Certification specifics such as CE, SIL, and IP ratings vary by region and are typically listed in the Eaton datasheet for the EDR-3000-2C0BA0. The product page notes compliance as provided by the manufacturer, so consult the official Eaton specification sheet for your target market to confirm approvals, installation prerequisites, and regional regulatory requirements before deployment.
ROI is driven by reduced downtime, faster fault clearance via zone selective interlocking, and easier SCADA integration for remote diagnostics. The four-input, four-output I/O, combined with Modbus RTU/DNP3 RTU over RS485, enables centralized monitoring and streamlined maintenance. Energy metering and accurate protection coordination help optimize performance, lower maintenance costs, and extend equipment life across feeder circuits.