Eaton EDR-3000-2C0FB0 Distribution Relay - Fiber Optic RTU

Part Number: EDR-3000-2C0FB0
Manufacturer
Eaton
Part number
EDR-3000-2C0FB0

Quick Summary

Eaton distribution relay EDR-3000-2C0FB0 provides robust feeder protection for industrial power systems. It addresses commissioning delays and complex fiber-based integrations by delivering Modbus RTU or DNP3 RTU communications over fiber, along with flexible I/O. The unit supports CE-ready configurations and SIL-readiness where applicable, with conformal coating for harsh environments and a compact semi-flush mounting footprint. This combination delivers reliable protection, fast diagnostics, and scalable integration for modern automation architectures while aligning with long-term maintenance and total cost of ownership considerations.

Product Information

Extended Description

EDR-3000-2C0FB0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over Fiber Optic ST, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, over fiber optic ST,19-300Vdc, 40-250Vac, 50/60 Hz ,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C0FB0
UPC
786679142066
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over Fiber Optic ST
Current sensing inputs
1
I/O options
IRIG-B
Modbus / DNP3 RTU
over fiber optic ST
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Feature → Business Impact → Application: Fiber optic communication enables secure, interference-free remote monitoring and control, reducing communication outages and enabling rapid fault isolation in distributed networks. This leads to improved uptime and faster restoration of feeders in manufacturing lines and utility-like substations. Application: feed protection in harsh industrial environments where remote diagnostics are essential. Feature → Business Impact → Application: 4 inputs and 4 removable terminals provide flexible wiring and easy field upgrades, shortening installation times and reducing cabling errors. Application: modular feeder protection in new builds or retrofit projects. Feature → Business Impact → Application: Power supply range of 19-300Vdc and 40-250Vac with 50/60 Hz operation supports diverse plant power architectures, minimizing inventory of power supplies and simplifying spares management. Application: mixed voltage environments and multi-source facilities. Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over fiber optic ST delivers standardized, interoperable communications with SCADA or EMS, lowering integration risk and accelerating commissioning. Application: centralized monitoring and remote control. Feature → Business Impact → Application: 5A and 1A current sensing inputs allow precise fault detection and metering without adding external transducers, improving protection accuracy and energy management. Application: precise feeder protection and billing-grade metering. Feature → Business Impact → Application: Zone selective interlocking and removable I/O facilitate fast, selective tripping and simplified maintenance, reducing outage duration and improving safety. Application: substation feeder coordination and maintenance access. Feature → Business Impact → Application: Conformal coating and rugged mechanical design provide reliability in dirty, humid, or temperature-variant environments, lowering field failure rates and service calls. Application: outdoor enclosures or plant floor installations with exposure to dust and moisture. This approach combines protection performance with installation ease, compatibility with PowerPort-E configurations, and proven Eaton reliability for industrial automation projects while addressing common objections about fiber-based architectures and integration timelines.

Get a Quick Quote for a Eaton EDR-3000-2C0FB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2C0FB0? Enquire Now

FAQs

The EDR-3000-2C0FB0 is designed for semi-flush mounting with removable terminals, facilitating quick field wiring. Plan fiber optic ST cabling for Modbus RTU or DNP3 RTU, ensure 19-300Vdc or 40-250Vac supply compatibility, and verify space for a 7.49 in depth by 8.62 in height enclosure while routing feeds to 4 inputs and 4 outputs.
The unit supports 4 inputs and 4 outputs with current sensing inputs at 5A and 1A phase currents. It accepts a power supply range of 19-300Vdc or 40-250Vac, operates at 50/60 Hz, and provides fiber-based Modbus RTU or DNP3 RTU communication for remote control and monitoring.
Yes. Designed as a feeder distribution relay with modules for zone selective interlocking, current protection, and metering, it integrates with SCADA systems over fiber, enabling fast fault isolation and coordinated protection for feeders in industrial substations or large manufacturing plants.
Compliance information is provided by the manufacturer. Typical configurations support CE-related standards and SIL readiness where applicable. For exact certifications and IP ratings, consult Eaton documentation or contact the manufacturer for a configuration-specific assurance.
Warranty is per Eaton policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. Eaton also provides technical documentation, datasheets, and application notes to support installation, configuration with PowerPort-E, and ongoing maintenance.