Eaton EDR-3000-2C0IB0 Distribution Relay - Coated PCB
Part Number: EDR-3000-2C0IB0
Quick Summary
The Eaton distribution relay is designed to monitor and control feeder circuits in industrial power systems. This solution addresses the common challenge of integrating protection logic across RS-485 and Ethernet while keeping wiring manageable and panel space efficient. In practice, engineers look for devices with rugged construction, versatile communications, and proven reliability; typical expectations include robust environmental resilience, scalable I/O, and easy configuration for SCADA integration. With 4 inputs and 4 outputs, removable terminals, and Modbus communications over RS-485 and Ethernet, the EDR-3000 supports scalable feeder protection in modern automation facilities while aligning with maintenance and lifecycle cost goals.
Product Information
Extended Description
EDR-3000-2C0IB0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, over RS-485, over Ethernet RJ-45, Conformal Coated Circuit Boards, 19-300Vdc, 40-250Vac, 50/60 Hz ,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C0IB0
UPC
786679140673
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Current sensing inputs
1
I/O options
IRIG-B
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
E-series protective relays
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - EDR-3000-2C0IB0
Selling Policy 25-000 - Distribution and Control Products and Services
Feature: Flexible power and IO configuration — 4 inputs and 4 outputs with removable terminals and a wide power supply range of 19-300 Vdc / 40-250 Vac. Business Impact: simplifies panel wiring, reduces installation time, and lowers total cost of ownership. Application: feeder protection in control cabinets across varied geographic locations. Feature: Dual communication options — Modbus RTU over RS-485 and Modbus TCP over Ethernet RJ-45, plus IRIG-B option. Business Impact: seamless SCADA integration, easy remote monitoring, and improved asset visibility. Application: plant-wide data collection and fault diagnostics in industrial automation. Feature: Conformal coating and rugged design — Conformal Coated Circuit Boards for harsh environments. Business Impact: higher uptime, reduced maintenance frequency, and longer service life. Application: outdoor or dusty factory floors and humid facilities. Feature: Zone selective interlocking and current sensing — Zone interlock (1) and 1 current sensing input. Business Impact: faster selective tripping, reduced outage impact, and improved safety margins. Application: coordinated feeder protection and fault localization in electrical networks. Feature: Versatile mounting and configuration — Semi-flush mounting with removable terminals and IRIG-B support. Business Impact: simpler installation, easier field servicing, and reliable time synchronization for event logging. Application: retrofit projects and new builds in industrial plants and data centers.
Get a Quick Quote for a Eaton EDR-3000-2C0IB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-3000-2C0IB0?
Enquire Now
FAQs
Begin by confirming the 4 input and 4 output configuration and ensure your panel power supply meets 19-300 Vdc or 40-250 Vac. Use the removable terminals for quick wiring and mount the unit in semi-flush orientation. Connect Modbus RTU over RS-485 and Modbus TCP over Ethernet for SCADA integration, then verify RS-485 and Ethernet connectivity with the PowerPort-E configuration tools.
The EDR-3000-2C0IB0 provides Modbus RTU over RS-485 and Modbus TCP over Ethernet RJ-45 for plant-wide integration. An optional IRIG-B input supports precise time synchronization. These interfaces enable seamless data exchange with SCADA systems, PMUs, and other protection relays, improving fault diagnosis and remote monitoring capabilities.
Yes. The relay includes zone selective interlocking with a dedicated interlock input and current sensing for selective coordination. This feature reduces outage impact by speeding up fault isolation and allows protection schemes to differentiate faults within feeder networks, which is especially beneficial in large distribution and industrial electrical infrastructure.
The device features a semi-flush mounting method with four removable terminals. Dimensions are 7.49 inches in depth, 8.62 inches in height, and 6.82 inches in width. This compact footprint supports easier installation in crowded electrical panels and enables straightforward field servicing without compromising access to connections.
Warranty details follow Eaton Selling Policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. Compliance information is provided by the manufacturer; users should verify exact CE or other regulatory certifications with Eaton for their region and application requirements to ensure regulatory alignment and safe operation.