Eaton EDR-3000-2C1EA1 Distribution Relay - Profibus-DP

Part Number: EDR-3000-2C1EA1
Manufacturer
Eaton
Part number
EDR-3000-2C1EA1

Quick Summary

Eaton distribution relay EDR-3000-2C1EA1 enables direct feeder protection and remote metering for industrial automation panels. Engineers often juggle multiple relays and interfaces, creating wiring complexity and slower fault isolation. Certifications vary by region, and the data here shows Compliances: Contact Manufacturer, so verify exact certifications with Eaton for your application. As a Profibus-DP capable distribution relay over D-Sub/RS-485, it delivers reliable bus communication and scalable I/O with a compact footprint, enabling streamlined protection, metering, and control in a single module.

Product Information

Extended Description

EDR-3000-2C1EA1 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4,Feeder, over D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C1EA1
UPC
786679141212
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
1
I/O options
IRIG-B Sensitive Ground Input
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
0
Wide voltage tolerance simplifies cross-vendor deployments: power this unit from 19-300Vdc or 40-250Vac, reducing part stocking and simplifying installation across mixed electrical systems in automation plants. Business impact: faster commissioning and fewer stockouts; Application: feeder protection in mixed DC/AC environments. The four inputs and four outputs with removable terminals and projection mounting streamline wiring and mechanical fit in space-constrained panels. Business impact: lower wiring errors and quicker panel build; Application: centralized control and protection for feeders. Profibus-DP over D-SUB/RS-485 provides robust fieldbus integration, reducing commissioning time and simplifying diagnostics. Business impact: improved MTBF and faster fault isolation; Application: networked machine lines and distributed control architectures. Current sensing inputs, 1 channel, and Zone Selective Interlocking support coordinated protection and metering, lowering downtime. Business impact: selective tripping minimizes outages; Application: high-availability arrays. I/O options include IRIG-B sensitive ground input for time synchronization, aligning protection actions with exact system timing. Business impact: deterministic protection schemes; Application: critical power distribution. The device’s 50/60 Hz compatibility and 4x4 I/O footprint align with common industrial standards, supporting scalable expansion and straightforward maintenance. Warranty follows Eaton policy, helping minimize lifecycle risk. Business impact: predictable support; Application: long-term asset management.

Get a Quick Quote for a Eaton EDR-3000-2C1EA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2C1EA1? Enquire Now

FAQs

The EDR-3000-2C1EA1 uses projection mounting with removable terminals, designed for straightforward panel installation and fast field wiring. It provides four input and four output channels, enabling compact, reliable connections in feeder protection schemes. This layout minimizes enclosure adjustments and reduces terminal tangling, improving on-site assembly times and reliability in demanding industrial environments.
This model supports a wide power range: 19-300Vdc or 40-250Vac, with a 50/60 Hz frequency rating. It features four inputs and four outputs, with removable terminals for easy maintenance. Current sensing inputs are available (one channel), and the unit supports Zone Selective Interlocking (1). These specs enable flexible protection, metering, and control within existing electrical architectures.
Yes. The EDR-3000-2C1EA1 is designed for feeder protection and supports Profibus-DP communications over D-Sub / RS-485. This enables deterministic data exchange for protection, metering, and control across a distributed automation network, reducing wiring complexity and enabling centralized coordination of protection schemes in manufacturing or process environments.
The product data indicates Compliances: Contact Manufacturer, so exact certifications (CE, SIL, IP, etc.) should be confirmed with Eaton for your region and application. When specifying this device, request current certification documentation and validation for your target market to ensure regulatory alignment and full regulatory acceptance in your installation.
Eaton lists a one-year warranty from installation or 18 months from shipment, whichever occurs first. The EDR-3000 consolidates protection, metering, and bus communication into a single 4x4 module, reducing wiring, gear, and commissioning time. This leads to lower maintenance costs and faster fault isolation, supporting a clearer path to a lower total cost of ownership in feeder protection projects.