Eaton EDR-3000-2C1GA1 Distribution Relay - RS-485

Part Number: EDR-3000-2C1GA1
Manufacturer
Eaton
Part number
EDR-3000-2C1GA1

Quick Summary

Eaton distribution relay EDR-3000-2C1GA1 provides feeder protection and monitoring for industrial power distributions. Engineers often struggle with coordinating protection schemes, reliable remote communications, and seamless integration into existing control cabinets in harsh environments. Compliances for this model are listed as Contact Manufacturer, so it's essential to verify CE, SIL, IP ratings, and regulatory alignment with Eaton during procurement. By supporting Modbus RTU or DNP3 RTU over RS-485 and covering a broad power range, this relay enables scalable, cost-efficient panel upgrades and easier interoperability with existing SCADA and PLC systems. In short, it blends protection accuracy with flexible communication for modern industrial automation ecosystems.

Product Information

Extended Description

EDR-3000-2C1GA1 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4,Feeder, D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C1GA1
UPC
786679141502
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
Sensitive Ground Input IRIG-B
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
0
Feature: 4 inputs and 4 outputs enable comprehensive feeder protection and metering coverage. Business impact: consolidates protection logic and IO into a single device, reducing panel complexity and wiring costs. Application: ideal for feeders in control cabinets or small substations where space is at a premium and reliability is critical. Feature: Current sensing inputs with 5A/1A phase currents provide precise trip and coordination. Business impact: improves selectivity and minimizes nuisance trips, lowering outage duration and maintenance costs. Application: medium- and low-voltage feeders requiring accurate current-based protection and metering. Feature: Power supply range of 19–300 Vdc and 40–250 Vac with 50/60 Hz operation. Business impact: compatible with diverse plant electrical architectures and reduces the need for multiple power supplies. Application: new builds and upgrades across mixed DC/AC power environments. Feature: Communication via Modbus RTU or DNP3 RTU over D-Sub / RS-485. Business impact: enables seamless remote monitoring, integration with SCADA, and easier data collection for analytics. Application: panel enclosures, automation cabinets, and remote substations. Feature: Projection mounting and removable terminals for fast field installation and easy maintenance. Business impact: reduces commissioning time and simplifies troubleshooting without sacrificing reliability. Application: retrofit projects in existing racks or compact control panels. Feature: Zone selective interlocking capacity and 1 current sensing input support coordinated protection schemes. Business impact: enhances protection coordination across feeders, reducing fault impact. Application: complex plant layouts with multiple feeders requiring synchronized tripping. Feature: 4-channel IO with IRIG-B-sensing input option and Sensitive Ground Input compatibility. Business impact: supports time-synced operations and precise earth- fault detection in critical processes. Application: aerospace, defense, or power-intensive industries with strict timing and grounding requirements. These capabilities collectively deliver measurable outcomes: faster fault isolation, lower downtime, streamlined wiring, easier vendor support, and improved compliance traceability for industrial power protection projects.

Get a Quick Quote for a Eaton EDR-3000-2C1GA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2C1GA1? Enquire Now

FAQs

Plan for projection mounting and ensure removable terminals are accessible for maintenance. The unit provides 4 inputs and 4 outputs, accepts 19–300 Vdc or 40–250 Vac supply, and supports RS-485 communication. Allow space for wiring harnesses, verify proper grounding, and coordinate IRIG-B option if time-synced operations are needed. This setup minimizes commissioning time and simplifies field adjustments.
The EDR-3000-2C1GA1 uses RS-485 to deliver Modbus RTU or DNP3 RTU protocols, enabling remote monitoring, SCADA integration, and centralized data collection. This supports efficient feeder status reads, setpoint adjustments, and fault reporting without onsite access. Ensure your master device references the correct addressing scheme and configure baud rate and parity to match your network topology.
The model provides robust protection features and flexible IO, suitable for many industrial panels. Exact environmental ratings, IP protection, and SIL capabilities require confirmation from Eaton, as indicated by the Compliances field. Plan for regional regulatory checks and validate installation conditions with Eaton to ensure alignment with your plant’s harsh-environment requirements.
Validate the power supply range (19–300 Vdc, 40–250 Vac) and frequency (50/60 Hz), as well as current sensing input configuration (1 input) and phase current options (5A or 1A). Confirm certifications with Eaton for CE, IP ratings, or SIL capabilities, since the datasheet notes Compliance as Contact Manufacturer. Also verify installation standards for projection mounting and terminal accessibility.
ROI comes from reduced wiring complexity with 4 IO channels, improved protection selectivity reducing nuisance trips, and remote visibility via Modbus/DNP3 communications. Faster commissioning and easier maintenance lower labor costs, while enhanced reliability reduces downtime. In retrofit scenarios, the consolidation of protection and metering into a single device often shortens project timelines and extends asset life.