Eaton EDR-3000-2C1GB0 Distribution Relay - Modbus/DNP3

Part Number: EDR-3000-2C1GB0
Manufacturer
Eaton
Part number
EDR-3000-2C1GB0

Quick Summary

Eaton distribution relay is a compact feeder protection device for monitoring and controlling power distribution. Engineers often struggle to integrate legacy protection schemes with modern SCADA interfaces, leading to delays and risk. For certifications, confirm status with the manufacturer; consult Eaton datasheets for CE, SIL, or IP ratings where applicable. In practice, the EDR-3000-2C1GB0 enables flexible Modbus RTU and DNP3 RTU communication over RS-485, with a wide power range, supporting scalable feeder protection and integrated analytics that drive uptime and operational efficiency.

Product Information

Extended Description

EDR-3000-2C1GB0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4,Feeder, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C1GB0
UPC
786679142790
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
Sensitive Ground Input IRIG-B
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
Wide power supply range and flexible I/O enable installation across diverse sites, reducing power conversion needs and enabling time-saving wiring. Feature → Business Impact → Application: Flexible power input (19-300 Vdc / 40-250 Vac) reduces cabinet clutter and simplifies retrofit projects in manufacturing lines and data centers, improving installation speed and reliability for feeder protection tasks. Feature → Business Impact → Application: Four inputs and four outputs with removable terminals facilitate quick commissioning and easy maintenance, allowing faster fault isolation and reduced downtime in industrial plants. Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over D-SUB/RS-485 delivers robust SCADA integration, enabling centralized monitoring, alarm management, and improved energy metering across multiple feeders. Feature → Business Impact → Application: Current sensing input and zone selective interlocking shorten trip times and coordinate protection across the bus, lowering risk of arc flash and equipment damage in substations and control rooms. Feature → Business Impact → Application: Conformal coated circuit boards and a semi-flush mounting method increase reliability in challenging environments and simplify panel design, reducing field maintenance costs and improving long-term ROI.

Get a Quick Quote for a Eaton EDR-3000-2C1GB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-3000-2C1GB0? Enquire Now

FAQs

The unit features removable terminals for straightforward field wiring, supports RS-485 communication via D-Sub connectors for Modbus RTU or DNP3 RTU, and is designed for semi-flush mounting in control panels. With 4 inputs and 4 outputs, it accommodates compact feeder protection layouts and simplifies panel design for quick commissioning.
Key specs include 4 inputs and 4 outputs, 1 current sensing input, and a power supply range of 19–300 Vdc or 40–250 Vac at 50/60 Hz. The device supports current protection and metering with selectable phase currents of 5 A or 1 A, enabling accurate protection and data capture for energy management.
Yes. It’s designed for feeder protection with zone selective interlocking to coordinate trips, supports Modbus RTU/DNP3 RTU for SCADA integration, and provides reliable protection and metering in industrial feeders, data centers, and manufacturing facilities.
Compliances are listed as Manufacturer to be consulted; verify CE, SIL, IP ratings, and other standards in Eaton’s official datasheets and certification documents to ensure alignment with your facility’s regulatory requirements.
Conformal coating improves reliability in harsh environments, removable terminals simplify maintenance, and the integration with Modbus RTU/DNP3 RTU reduces wiring and commissioning time. These features collectively reduce downtime, lower maintenance costs, and deliver a favorable return on investment through enhanced uptime.