Eaton EDR-3000-2C1LB0 Distribution Relay - Mbus TCP/DNP3
Part Number: EDR-3000-2C1LB0
Quick Summary
Eaton distribution relay EDR-3000-2C1LB0 enables robust feeder protection and real-time monitoring for industrial power networks. Engineers often contend with lengthy fault isolation times and the challenge of integrating protective relays with modern SCADA and fieldbus systems. Compliances and certifications vary by region; consult Eaton for CE, SIL, or IP ratings applicable to your installation. With four configurable inputs and outputs, plus Mbus TCP or DNP3 TCP/UDP communications, the EDR-3000-2C1LB0 supports scalable feeder architectures and easier commissioning. This translates to faster deployment, improved data visibility, and reduced downtime across industrial facilities.
Product Information
Extended Description
EDR-3000-2C1LB0 Eaton: Eaton, distribution relay, EDR-3000, Distribution relay, Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet, 5A, 1A, 40-250 Vac, 19-300 Vdc, 4, 4, Removable, Feeder, 19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-3000-2C1LB0
UPC
786679141755
Product Length/Depth
7.49 in
Product Height
8.62 in
Product Width
6.82 in
Product Weight
5.3 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-3000
Conformal coating
Conformal Coated Circuit Boards
Communication
Mbus TCP or DNP3 TCP/UDP over LC duplex FO Enet
Current sensing inputs
1
I/O options
Sensitive Ground Input IRIG-B
Modbus / DNP3 TCP
over LC duplex fiber optic Ethernet
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering
Zone selective interlocking
1
Number of inputs
4
Number of outputs
4
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
0
E-series protective relays
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - EDR-3000-2C1LB0
Feature: Mbus TCP or DNP3 TCP/UDP over LC duplex fiber optic Ethernet enables secure, long-range communication between the relay and SCADA systems. Business Impact: Enables seamless remote monitoring, faster fault diagnosis, and reliable integration with existing control networks. Application: Ideal for feeder protection in large manufacturing plants and substations where data integrity and timely alarms are critical. Long-tail keywords: Mbus TCP, DNP3 TCP, SCADA integration, remote diagnostics. Feature: Four inputs and four outputs with removable terminals simplifies field wiring and servicing. Business Impact: Reduces installation time and maintenance downtime while improving reliability. Application: Common in modular feeder assemblies and retrofit projects requiring flexible I/O. Long-tail keywords: removable terminals, four-input four-output, field wiring. Feature: Phase current options of 5A and 1A support precise current sensing and metering. Business Impact: Enables accurate protection calculations and energy monitoring, reducing misoperations and improving grid visibility. Application: Current protection and metering in feeders and distributed loads. Long-tail keywords: phase current, current sensing, metering. Feature: Conformal coating on circuit boards and IRIG-B support enhance reliability in harsh environments and timing synchronization. Business Impact: Improves uptime in harsh industrial settings and ensures time-stamped data for event trees. Application: Substation and outdoor installations. Long-tail keywords: conformal coated boards, IRIG-B, rugged electronics. Feature: Zone selective interlocking (1) reduces disruption by selective tripping, improving overall system availability. Business Impact: Minimizes equipment damage and downtime during faults, lowering maintenance costs. Application: High-resilience feeder protection in critical processes. Long-tail keywords: zone selective interlocking, selective tripping, high-availability feeders.
Get a Quick Quote for a Eaton EDR-3000-2C1LB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-3000-2C1LB0?
Enquire Now
FAQs
The EDR-3000-2C1LB0 uses four removable terminals and a semi-flush mounting method, simplifying both initial wiring and future maintenance. It supports 19-300Vdc or 40-250Vac power, 50/60 Hz operation, and Mbus TCP or DNP3 TCP/UDP communications for easy integration with SCADA systems and remote diagnostics.
Key specs include four inputs and four outputs, phase current ratings of 5A/1A for sensing, and current protection and metering capabilities. It also offers zone selective interlocking (1) to limit tripping to the faulted section, with conformal-coated PCB assembly for reliability in demanding environments.
Yes. The EDR-3000-2C1LB0 is designed for feeder protection with flexible I/O, robust communication options, and timing synchronization features like IRIG-B. Its remote communication and scalable I/O support make it suitable for both plant feeders and remote substations requiring fast fault isolation.
Compliances are listed as 'Contact Manufacturer' in the data. For CE, SIL, or IP ratings, confirm with Eaton to obtain the exact certifications applicable to your region and installation, ensuring traceability for regulatory requirements.
Removable terminals and a conformal-coated design simplify field maintenance, reducing downtime during servicing. The combination of remote Mbus/DNP3 communication, current protection and metering, and zone selective interlocking delivers faster fault isolation, improved uptime, and lowered lifecycle costs through reduced spares and faster commissioning.