Eaton EDR-5000-2A0EB0 Distribution Relay - Profibus-DP

Part Number: EDR-5000-2A0EB0
Manufacturer
Eaton
Part number
EDR-5000-2A0EB0

Quick Summary

The Eaton distribution relay EDR-5000-2A0EB0 provides feeder protection for industrial power networks. Engineers often struggle with coordinating selective tripping while integrating legacy controls and modern fieldbus communication. Key certifications to verify include CE compliance, SIL levels where applicable, and IP enclosure protection, depending on installation. This relay offers Profibus-DP over D-Sub / RS-485, 8 inputs and 11 outputs, and a wide power range for cabinet applications. With removable terminals and conformal coated circuit boards, it supports easier maintenance and rugged operation in demanding environments. By aligning with Eaton's E-Series ecosystem, it reduces integration risk and supports scalable protection strategies across multiple feeders.

Product Information

Extended Description

EDR-5000-2A0EB0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, over D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A0EB0
UPC
786679143735
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Current Protection and Metering Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Profibus-DP communication over D-Sub/RS-485 enables seamless integration with existing control systems, reducing wiring effort and enabling remote supervision. This minimizes commissioning time and enables centralized protection settings across multiple feeders. Eight inputs and eleven outputs provide expanded I/O for zone selective interlocking and metering functions. The direct IO footprint supports complex protection schemes without adding external modules, cutting cabinet size and wiring complexity. In practice, users can implement current and voltage protection and metering within the same device, improving reliability. Wide power supply range of 19-300 VDC and 40-250 VAC, combined with 50/60 Hz compatibility, allows installation in various regional networks without additional power conditioning. This flexibility reduces inventory needs and supports global deployments in factories and data centers. Conformal coated circuit boards protect against moisture, dust, and corrosive atmospheres, extending service life in harsh environments. Removable terminals simplify field updates and maintenance, minimizing downtime during replacements or rewiring. Current sensing inputs (one channel) support accurate protection and metering; phase current options of 5A and 1A accommodate different sensor types. Voltage and power protection metering capabilities help verify load balance and fault detection in real time. IRIG-B Trip Coil Monitor provides precise trip timing for coordinated protection, while zone selective interlocking (1) enables selective feeder isolation to minimize outage impact. Mounting via semi-flush installation and removable terminals streamline mounting in tight enclosures and simplify service. Being compatible with Eaton’s E-Series platform, it integrates with other protection relays and modules for scalable, standardized upgrades.

Get a Quick Quote for a Eaton EDR-5000-2A0EB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2A0EB0? Enquire Now

FAQs

Installation begins with confirming Profibus-DP over D-Sub / RS-485 compatibility and wiring the 8 inputs and 11 outputs to the feeder system. Use the semi-flush mounting method to fit compact control cabinets, and connect removable terminals for straightforward field service. Plan for conformal coating in harsh environments to ensure long-term reliability and minimize maintenance downtime.
Key specs include a power supply range of 19-300 VDC and 40-250 VAC, operation at 50/60 Hz, and current sensing inputs (1 channel). The device supports current protection and metering, voltage protection and metering, and power protection and metering, with 8 inputs and 11 outputs to enable robust protection schemes and accurate fault detection.
Yes. The unit supports zone selective interlocking with a dedicated interlock capability (1), enabling selective feeder isolation during faults. This minimizes system-wide outages and improves restoration times, particularly in complex switchgear arrangements where coordination with other protective devices is critical.
Prioritize a robust enclosure with conformal-coated circuit boards to resist moisture and dust. Take advantage of removable terminals for easy field updates and maintenance, and ensure proper cable routing to prevent EMI. The device’s wide power range supports regional supply variations, reducing the need for additional power conditioning equipment.
The relay reduces commissioning time through built-in Profibus-DP integration and modular I/O, lowers wiring complexity with removable terminals, and extends service life via conformal coating. These factors translate into lower maintenance downtime, faster fault diagnosis, and greater protection coverage per feeder, delivering a favorable total cost of ownership over standard relay implementations.