Eaton EDR-5000-2A0GA0 Distribution Relay - Modbus RTU

Part Number: EDR-5000-2A0GA0
Manufacturer
Eaton
Part number
EDR-5000-2A0GA0

Quick Summary

An Eaton distribution relay EDR-5000-2A0GA0 provides robust feeder protection for industrial power systems. Engineers often struggle with coordinating protection schemes, remote monitoring, and seamless SCADA integration without adding complexity or cost. This model supports Modbus RTU or DNP3 RTU over RS-485 and offers eight inputs and eleven outputs for flexible control and signaling. Compliance details should be confirmed with the manufacturer, and the included warranty covers one year from installation or eighteen months from shipment. With a broad voltage range (19–300 VDC, 40–250 VAC) and 50/60 Hz compatibility, it delivers reliable protection while enabling scalable, interoperable solutions for modern facilities.

Product Information

Extended Description

EDR-5000-2A0GA0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil Monitor
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A0GA0
UPC
786679143865
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over RS-485 enables seamless SCADA integration and remote monitoring, reducing onsite diagnostics time and enabling faster fault isolation in feeder circuits. This supports higher system availability and simplified data collection for predictive maintenance in plant power distribution. Feature → 8 inputs and 11 outputs provides ample I/O for protection signaling, metering, and interlocking control, streamlining panel wiring and reducing custom wiring costs. Application: Feeder protection in control panels and switchgear, with clear signaling to PLCs and SCADA. Feature → Power supply range 19-300 VDC / 40-250 VAC offers installation versatility across mixed power environments, minimizing voltage adaptation needs. Application: Global facilities with varying electrical systems benefit from a single-relay solution. Feature → Phase current options 5A and 1A align with standard protection schemes, improving sensing accuracy and compatibility with common metering devices. Application: Current protection and metering met in feeder protection schemes. Feature → 50/60 Hz compatibility ensures reliable operation in regional power grids without reconfiguration, improving global deployability. Application: Multisite deployments across regions with different frequency standards. Feature → Semi-flush mounting and removable terminals simplify installation and maintenance, reducing commissioning time and labor costs. Application: Modern control panels and retrofit projects where quick field servicing is essential. Feature → Zone selective interlocking (1) enables faster fault isolation, reducing fault-clearing time and minimizing collateral damage to adjacent feeders. Application: Critical plant sections requiring tight protection coordination and minimized downtime.

Get a Quick Quote for a Eaton EDR-5000-2A0GA0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2A0GA0? Enquire Now

FAQs

The EDR-5000-2A0GA0 supports Modbus RTU or DNP3 RTU communications over RS-485 via a D-Sub interface. This enables straightforward integration with existing SCADA and PLC networks, reducing wiring complexity and enabling remote diagnostics. It also supports standard protection signaling and metering data exchange, which helps maintain coordinated protection schemes across feeders.
Yes. With 8 inputs and 11 outputs, 5 A and 1 A phase current options, and a wide voltage range, the unit is designed for robust feeder protection in control panels and switchgear. Its RS-485 Modbus/DNP3 communication facilitates real-time monitoring and coordinated tripping, improving reliability and reducing downtime in plant power distribution.
Plan for semi-flush mounting and removable terminals to simplify wiring and maintenance. The device supports 19-300 VDC and 40-250 VAC power, 50/60 Hz operation, and zone selective interlocking. Ensure allocation of 8 input lines and 11 output lines in your panel layout, and confirm the communication wiring for Modbus RTU or DNP3 RTU over RS-485.
Compliance details for the EDR-5000-2A0GA0 should be confirmed with the manufacturer. The product page notes Compliances as 'Contact Manufacturer.' For regulatory certifications such as CE or UL, consult Eaton’s technical documentation or regional approvals to ensure alignment with your facility requirements and local codes.
The relay’s zone selective interlocking capability, along with its extensive I/O and SCADA-friendly communications, reduces downtime and protects critical feeders more effectively. Removable terminals and a wide voltage range simplify installation and future upgrades, lowering maintenance costs and enabling faster ROI through improved reliability and easier integration with existing control systems.