Eaton EDR-5000-2A0GB1 Distribution Relay - RS-485

Part Number: EDR-5000-2A0GB1
Manufacturer
Eaton
Part number
EDR-5000-2A0GB1

Quick Summary

Eaton distribution relay EDR-5000-2A0GB1 provides feeder protection and metering for industrial electrical systems. Engineers often struggle to integrate protective relays over RS-485 networks while maintaining consistent protection settings across multiple sites. Certification notes: CE, UL, and IP ratings are not listed in the provided data; please confirm with Eaton for your region and project requirements. With Modbus RTU or DNP3 RTU over RS-485 support, the device delivers reliable plant communication and centralized control for scalable protection. This combination supports energy management, fault isolation, and improved uptime, while the optional I/O and configuration options help tailor protection to your specific feeder topology.

Product Information

Extended Description

EDR-5000-2A0GB1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A0GB1
UPC
786679143957
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Wide power supply range and flexible installation reduce inventory requirements and simplify site wiring. The EDR-5000-2A0GB1 supports 19-300 Vdc or 40-250 Vac input, enabling a single device to cover diverse plant voltages and minimizing conversion hardware. Business impact includes a smaller spare parts ecosystem and faster commissioning across mixed- voltage feeders, with applications in factories and substations. Eight inputs and eleven outputs provide rich protection and metering capabilities, including zone selective interlocking for coordinated trips and reduced outage impact. The large I/O set translates into faster fault isolation and improved network visibility in SCADA environments, translating into measurable uptime gains. Modbus RTU or DNP3 RTU over RS-485 enables seamless integration with plant control systems, energy meters, and historian data, lowering integration costs and accelerating project timelines. The inclusion of IRIG-B Trip Coil Monitor as an I/O option strengthens timing accuracy for protection schemes, while conformal-coated printed circuit boards support operation in dusty or humid environments, reducing maintenance cycles. The projection mounting and removable terminals streamline installation and service, helping technicians connect and rewire with minimal downtime, which is critical for feeder protection reliability and fast fault restoration.

Get a Quick Quote for a Eaton EDR-5000-2A0GB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2A0GB1? Enquire Now

FAQs

Begin by mounting the unit using its projection mounting method, then connect the 8 removable terminals for power, inputs, and outputs. Wire the RS-485 D-Sub for Modbus RTU or DNP3 RTU as specified, configure the 5A/1A phase current sensing, and verify 50/60 Hz operation. Confirm supply is within 19-300 Vdc or 40-250 Vac and perform a functional test to validate protection coordination across feeders.
The EDR-5000-2A0GB1 supports Modbus RTU or DNP3 RTU over RS-485, enabling integration with SCADA, HMI, and energy-management systems. It features eight input channels, eleven outputs, and one current-sensing input, with an additional I/O option for IRIG-B Trip Coil Monitor. The device operates on 50/60 Hz and accepts 19-300 Vdc or 40-250 Vac, making it suitable for mixed-voltage facilities.
Yes. Its eight inputs and eleven outputs support comprehensive feeder protection and metering, with 5A/1A phase current ratings and zone selective interlocking for coordinated protection. The RS-485 communication enables centralized monitoring and data logging, while the wide supply range accommodates diverse plant voltages. This makes it ideal for manufacturing lines, data centers, and substations needing reliable feeder protection.
Key resources include the Eaton Specification Sheet for the EDR-5000-2A0GB1, a general E-series protective relays brochure, and multiple training videos on advanced configuration with PowerPort-E. Practical setup guides, wiring diagrams, and field installation notes are accessible via Eaton’s site links, helping with commissioning, maintenance, and upgrades.
The product is covered by Eaton’s Selling Policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. For field service, spare parts, and software updates, contact Eaton support or your authorized distributor to confirm regional terms and any extended warranty options.