Eaton distribution relay EDR-5000-2A0HA1 - 61850
Part Number: EDR-5000-2A0HA1
Quick Summary
The Eaton distribution relay is a compact, multi-protocol protection device designed for feeder applications in industrial power systems. Engineers often wrestle with integrating diverse communication protocols and coordinating protection across multiple feeders; this device simplifies that by supporting 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45 in one compact unit. While exact compliance details for this model should be confirmed with Eaton, many protective-relay products in this family align with CE, UL, and RoHS standards, with variations by integration and region. By combining flexible power input ranges, zone selective interlocking, and extensive I/O, the EDR-5000 adds value to automation strategies, improves reliability, and reduces total cost of ownership for feeders in manufacturing plants and utilities.
Product Information
Extended Description
EDR-5000-2A0HA1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A0HA1
UPC
786679143971
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Programming an Eaton E-Series Relay, Step 2: Getting Started with PowerPort-E
Eaton Specification Sheet - EDR-5000-2A0HA1
Feature: Multi-protocol communications enable seamless integration with industrial Ethernet standards. Impact: reduces engineering time, minimizes wiring complexity, and lowers integration risk by providing 61850, M-Bus TCP, and DNP3 TCP/UDP on a single device. Application: ideal for feeder protection and remote SCADA monitoring in mixed-vendor automation environments. Feature: Broad power supply range and scalable I/O simplify installation. Impact: enables a single-supply operation from 19-300Vdc or 40-250Vac, reducing stocking and wiring; 8 inputs and 11 outputs provide flexible protection and metering options. Application: field installations in substations and manufacturing floors. Feature: Projection mounting and removable terminals enhance serviceability. Impact: faster commissioning and easier field retrofits with minimal panel disruption. Application: retrofit projects and new installations in compact control cabinets. Feature: Zone selective interlocking enhances protection coordination. Impact: faster fault isolation, reduced arc-flash energy, and improved system reliability. Application: large distribution feeders in plants and utility-like environments. Feature: Time-sync and monitoring options via IRIG-B and various I/O options. Impact: precise event correlation and improved data integrity for SCADA/historian integrations. Application: critical protection sequences and post-event analysis. Feature: Rich communication options support remote monitoring and integration. Impact: supports Modbus/DNP3 over Ethernet, enabling centralized dashboards and asset management. Application: distributed control networks and industrial automation architectures.
Get a Quick Quote for a Eaton EDR-5000-2A0HA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-5000-2A0HA1?
Enquire Now
FAQs
The EDR-5000-2A0HA1 is designed for easy integration into existing protection architectures. It features removable terminals and projection mounting for flexible panel layouts, supports a wide input range (19–300Vdc, 40–250Vac), and provides 8 inputs with 11 outputs to match most feeder protection schemes. It commonly interoperates with Ethernet-based protocols and existing SCADA systems, reducing cabling complexity and commissioning time.
Key specs include 5A and 1A phase current sensing inputs, 50/60 Hz operation, 8 inputs and 11 outputs, and zone selective interlocking. These enable fast, coordinated tripping and selective isolation of faults, minimizing disruption to healthy feeders and optimizing system reliability across industrial networks.
Yes. It is purpose-built for feeder protection with robust communication options (61850, M-Bus TCP, DNP3 TCP), wide power supply ranges, and ZSI capability. Its flexible I/O and protection features support safe operation, fast fault clearance, and seamless integration with plant SCADA and energy management systems.
Compliances are listed as ‘Contact Manufacturer,’ so confirm regulatory certifications for your region with Eaton. Typical protective-relay families commonly reference CE and RoHS, with UL listings in relevant markets; however, certification status can vary by model and installation. Verify the exact certifications for the EDR-5000-2A0HA1 before procurement.
The device reduces maintenance by centralizing protection and monitoring in one module, lowering wiring and panel space needs. Zone selective interlocking shortens fault clearance, reducing downtime and energy loss. A standard one-year warranty supports lifecycle planning, while remote monitoring capabilities help optimize preventive maintenance and asset management.