Eaton distribution relay EDR-5000-2A0HB1 - 61850/DNP3
Part Number: EDR-5000-2A0HB1
Quick Summary
The Eaton distribution relay EDR-5000-2A0HB1 provides feeder protection for industrial electrical networks. Engineers often grapple with integrating multiple protocols and maintaining reliable monitoring across remote feeders, a challenge this device helps to simplify. While formal certifications are not listed on the spec page, common protection-relay requirements include SIL readiness, CE marking, and IP enclosure ratings; please confirm exact certifications with Eaton. This model emphasizes Ethernet-based protection and metering capabilities, delivering robust SCADA integration, and reducing downtime. The combination of open communication options and flexible power inputs supports scalable, cost-efficient protection architectures for modern facilities.
Product Information
Extended Description
EDR-5000-2A0HB1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A0HB1
UPC
786679144152
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Programming an Eaton E-Series Relay, Step 4: Advanced Configuration with PowerPort-E
Eaton Specification Sheet - EDR-5000-2A0HB1
Selling Policy 25-000 - Distribution and Control Products and Services
Feature → Business Impact → Application: 8 inputs and 11 outputs give rich interfacing for complex feeder protection schemes, enabling precise control and faster fault isolation. This translates to reduced outage time and improved plant availability, particularly in substations and manufacturing lines where quick reaction to faults is critical. Application: Feeder protection with Ethernet-based communication improves SCADA integration using 61850, M-Bus TCP, or DNP3 TCP/UDP over ENET RJ45, streamlining central monitoring and reducing engineering effort. Feature → Business Impact → Application: Power supply range of 19-300 Vdc and 40-250 Vac supports mixed-voltage networks, enabling a single device to serve both DC and AC feeders, lowering part counts and stocking costs. Application: Industrial plants with diverse power rails benefit from simplified procurement and installation. Feature → Business Impact → Application: Conformal coated circuit boards and IRIG-B Trip Coil Monitor I/O option enhance reliability in harsh environments and mission-critical protection applications. Application: Outdoor switchgear or factories with challenging humidity or vibration conditions gain resilience. Feature → Business Impact → Application: Projection mounting and removable terminals ease field installation and maintenance, reducing commissioning time and technician labor costs. Application: Controlled upgrades in retrofits or new builds. Feature → Business Impact → Application: Zone Selective Interlocking (0 or 1) enables faster fault isolation and reduced downstream load shedding, improving system stability during faults. Application: Large industrial drives and feeder networks require coordinated protection to minimize disruption. Feature → Business Impact → Application: 50/60 Hz operation with multi-protocol support aligns with global standards, facilitating cross-border deployments and vendor-neutral SCADA integration. Application: International projects or multi-site deployments benefit from consistent protection strategies. Feature → Business Impact → Application: Conformal coating and 1 current-sensing input support metering and protection schemes, enabling more accurate energy management and safer fault detection. Application: Utilities and industrial plants monitoring power quality and fault conditions with higher confidence.
Get a Quick Quote for a Eaton EDR-5000-2A0HB1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-5000-2A0HB1?
Enquire Now
FAQs
Begin by placing the unit in the panel with its projection-mount compatible footprint. Use removable terminals for DC and AC supply connections within the 19-300 Vdc / 40-250 Vac range. Connect 8 inputs and 11 outputs according to the feeder protection scheme, and integrate Ethernet communications for 61850, M-Bus TCP, or DNP3 TCP/UDP. Refer to the Eaton spec sheet for terminal labeling and wiring diagrams.
The EDR-5000-2A0HB1 supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45, enabling seamless SCADA integration. Modbus TCP compatibility is implied through DNP3/TCP pathways in typical Eaton installations. This broad protocol support simplifies remote monitoring, metering, and integration with modern protection schemes.
The device uses conformal-coated circuit boards to improve moisture and dust resistance. It supports a versatile power range and projection mounting for flexible installation. However, exact enclosure IP rating is not listed; confirm enclosure protection levels with Eaton for outdoor or harsh-environment deployments.
The product carries Eaton’s policy of one year from installation or eighteen months from shipment, whichever occurs first. For service beyond standard warranty, consult Eaton’s Selling Policy 25-000 and the current support channels. Access to datasheets and the specification sheet is provided to assist with troubleshooting and upgrades.
Yes. The device is rated for 19-300 Vdc and 40-250 Vac with 50/60 Hz operation, supporting both DC and AC feeder protection within a single protection scheme. With 8 inputs and 11 outputs plus zone selective interlocking, you can coordinate protections across mixed-voltage feeders while maintaining centralized monitoring via Ethernet-based protocols.