Eaton distribution relay EDR-5000-2A0IA1 - RS-485 & Ethernet
Part Number: EDR-5000-2A0IA1
Quick Summary
Eaton distribution relay EDR-5000 is built to monitor and control feeders in industrial electrical systems. Engineers often struggle with coordinating protection across multiple feeders and obtaining real-time visibility into fault conditions. Compliance details vary by region; consult Eaton for CE suitability, SIL readiness, and appropriate IP ratings as required. The unit supports Modbus RTU over RS-485 and Modbus TCP over Ethernet, enabling seamless remote monitoring and integration with existing DCS/SCADA architectures. In practice, this delivers faster fault isolation, reduced downtime, and improved protection coordination across complex automation networks. For procurement teams, the rugged form factor and 8 inputs/11 outputs simplify panel wiring and enable a scalable feeder protection strategy.
Product Information
Extended Description
EDR-5000-2A0IA1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay,5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, over RS-485, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Trip Coil Monitor,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A0IA1
UPC
786679144190
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Current sensing inputs
1
I/O options
Trip Coil Monitor IRIG-B
Modbus / DNP3 RTU
over RS-485
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Eaton Specification Sheet - EDR-5000-2A0IA1
Selling Policy 25-000 - Distribution and Control Products and Services
Eight inputs and eleven outputs streamline feeder protection logic with fewer relays and simpler wiring, which reduces panel size and installation time. This improves system reliability by consolidating sensing and control in one chassis, lowering cabling errors and maintenance costs. Applicable in medium to large industrial plants where multiple feeders require coordinated protection and fast tripping. Voltage sensing inputs and current sensing inputs provide precise protection decisions; a single voltage input and current input support accurate metering and protective coordination, enabling faster fault detection and reduced nuisance trips in demanding environments. This configuration is ideal for plants needing reliable power protection metering and clear fault visibility at the SCADA level. Power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz compatibility ensures compatibility with diverse plant electrical systems, reducing the need for multiple converters and easing installation in mixed-voltage environments. This supports flexible siting and easier retrofit projects while aligning with standard industrial power architectures. I/O options include Trip Coil Monitor IRIG-B and Zone Selective Interlocking, enabling coordinated tripping and precise protection sequencing across multiple feeders, which minimizes outage impact and improves overall system availability. This is particularly valuable in mission-critical facilities like data centers and manufacturing lines. Communication capabilities cover Modbus/ DNP3 RTU over RS-485 and Modbus TCP over Ethernet, enabling seamless integration with SCADA, EMS, and MES platforms. Remote monitoring, faster fault localization, and centralized protection coordination reduce field maintenance and drive measurable uptime improvements.
Get a Quick Quote for a Eaton EDR-5000-2A0IA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-5000-2A0IA1?
Enquire Now
FAQs
For panel installation, use the projection mounting and removable terminals to simplify wiring. The device features 8 inputs and 11 outputs, plus 1 current sensing input and 1 voltage sensing input, easing integration with existing feeder protection schemes. Pair via RS-485 for Modbus RTU or Ethernet for Modbus TCP, and verify 19-300Vdc or 40-250Vac power supply compatibility. Confirm panel space, grounding practices, and SCADA interface mappings using Eaton’s specification sheet for precise wiring diagrams.
Key specs include a power supply range of 19-300 Vdc or 40-250 Vac, 50/60 Hz operation, and phase current options of 5A and 1A. It provides 8 inputs and 11 outputs, with one voltage sensing input and one current sensing input for protection logic. The unit supports RS-485 Modbus RTU and Ethernet TCP/IP for remote communication, and includes Zone Selective Interlocking for coordinated protection.
Yes. The EDR-5000-2A0IA1 offers Zone Selective Interlocking (ZSI) with a dedicated interlock parameter, enabling selective tripping across feeders to minimize disturbance. It also provides robust metering and protection capabilities, making it appropriate for industrial facilities with multiple feeders, complex protection schemes, and a need for rapid fault isolation coordinated with SCADA.
Compliances indicate contacting the manufacturer for region-specific certifications. Eaton provides the E-Series protection relays and publishes specification sheets; confirmation of CE, SIL readiness, IP ratings, and other regulatory marks should be sourced from Eaton’s official documents to ensure alignment with local regulations and project requirements.
Maintenance benefits arise from consolidated protection logic in a single unit, reduced cabling, and remote monitoring via RS-485 or Ethernet, which lowers field service visits. ROI comes from faster fault isolation, reduced downtime, improved protection coordination, and easier compliance reporting—especially in facilities with numerous feeders and SCADA-enabled automation.