Eaton EDR-5000-2A1BA1 Distribution Relay - Modbus RTU

Part Number: EDR-5000-2A1BA1
Manufacturer
Eaton
Part number
EDR-5000-2A1BA1

Quick Summary

Eaton distribution relay EDR-5000-2A1BA1 provides centralized feeder control for industrial power systems. Engineers often face coordination gaps between feeders and reliable data exchange in demanding environments. In practice, ensure CE marking, IP ratings, and SIL compliance where applicable, since this type of device commonly sits at the feeder interface. This solution integrates Modbus RTU or DNP3 RTU over RS485 and wide input ranges to streamline SCADA integration and metering accuracy, delivering tangible business value through improved reliability and operational visibility.

Product Information

Extended Description

EDR-5000-2A1BA1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder, over RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection, Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A1BA1
UPC
786679144589
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
1
I/O options
Sensitive Ground Input Trip Coil Monitor IRIG-B
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Feature: Wide power and input range; Business Impact: Supports global installations with a single SKU, reducing inventory and commissioning time; Application: Feeder panels across multiple regions. Feature: 8 inputs and 11 outputs with removable terminals; Business Impact: Flexible I/O mapping simplifies panel design and maintenance, lowering wiring errors and startup time; Application: Complex feeder protection and metering schemes. Feature: Communication via Modbus RTU or DNP3 RTU over RS485; Business Impact: Enables seamless integration with SCADA systems and remote diagnostics, improving fault isolation and data transparency; Application: Industrial automation networks. Feature: Phase current options of 5A and 1A; Business Impact: Accurate current sensing supports selective protection and precise metering, reducing nuisance trips and improving reporting quality; Application: Power protection and metering in feeders. Feature: Sensing inputs covering current, voltage, and power protection/meters; Business Impact: Consolidates protection and metering into one device, reducing footprint and installation cost; Application: Power protection and metering in critical feeder applications. Feature: Zone selective interlocking capability; Business Impact: Improves selective tripping and reduces downstream fault propagation, enhancing system availability; Application: Medium to large electrical feeders. Feature: Projection mounting and removable terminals; Business Impact: Easier retrofits and field upgrades with minimal panel modification; Application: Retrofit projects and new installations.

Get a Quick Quote for a Eaton EDR-5000-2A1BA1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2A1BA1? Enquire Now

FAQs

The EDR-5000-2A1BA1 is designed for feeder control in industrial power systems and supports RS485 communications with Modbus RTU or DNP3 RTU. It provides eight inputs and eleven outputs with removable terminals and projection mounting, enabling flexible integration into existing panels and new installations alike.
Key specs include a wide power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz operation, 8 inputs, 11 outputs, and selectable phase currents of 5 A or 1 A. It also supports current, voltage, and power protection/meters for comprehensive feeder protection and metering.
Yes. Its modular design, extensive I/O, RS485 communication, and integrated metering capabilities make it well suited for feeder protection and metering in both data centers and industrial plants. Zone selective interlocking further enhances protection selectivity, reducing downtime and collateral damage during faults.
Verify applicable regulatory certifications (for example CE marking and safety standards) and any site-specific requirements. The product notes indicate Compliances: Contact Manufacturer, so confirm current certifications directly with Eaton and ensure suitability for your environment and safety/regulatory regime.
The device consolidates protection, metering, and communication, reducing panel footprint and wiring complexity, which lowers installation time and maintenance costs. Its RS485 communications enable remote diagnostics and SCADA integration, supporting faster fault resolution and improved energy reporting, contributing to lower total cost of ownership over the system’s life.