The Eaton distribution relay is a robust feeder protection device that delivers reliable monitoring and control for industrial power networks. Many teams struggle with integrating protection schemes across Modbus RTU or DNP3 RTU over RS485, leading to misconfigurations and delayed responses. While critical compliance considerations vary, CE marking and IP-related requirements are common in the sector and should be confirmed with Eaton for your specific installation. For businesses, this model offers flexibility with multiple communication options and scalable I/O, enabling tighter control of feeders, improved outage response times, and reduced engineering effort across sites in industrial automation environments.

Product Information

Extended Description

EDR-5000-2A1BB0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, over RS-485,19-300Vdc, 40-250Vac, 50/60 Hz ,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A1BB0
UPC
786679144596
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor Sensitive Ground Input
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over RS485 provides seamless integration with SCADA and metering systems, reducing wiring complexity and enabling remote diagnostics; Application: feeder protection networks in manufacturing and utilities. Feature → 8 inputs and 11 outputs with 1 current-sensing input and 5A/1A phase current ratings deliver precise protection logic and metering; Benefit: improved protection selectivity and actionable data for operators; Application: raw-material processing lines and critical feeders. Feature → Power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz compatibility supports global deployments; Benefit: lower hardware variety and simplified procurement; Application: multinational facilities and data centers. Feature → Conformal coated circuit boards and removable terminals streamline installation and maintenance; Benefit: enhanced reliability in harsh environments and easier field servicing; Application: outdoor or industrial plant installations with vibration or temperature variations. Feature → IRIG-B Trip Coil Monitor and Zone Selective Interlocking enable advanced protection schemes; Benefit: faster fault isolation and reduced arc flash risk; Application: large switchgear and feeder banks requiring coordinated protection.

Get a Quick Quote for a Eaton EDR-5000-2A1BB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2A1BB0? Enquire Now

FAQs

Begin with mounting the unit using the semi-flush method, then connect the eight inputs and eleven outputs to the protected feeder and associated devices. Attach RS485 lines for Modbus RTU or DNP3 RTU networks, ensuring proper termination and polarity. Use removable terminals for straightforward field wiring and reference Eaton’s installation guide for configuring zone selective interlocking and ground sensing options.
The device combines eight inputs, eleven outputs, and current sensing with configurable protection and metering across volatile feeder networks. Its Modbus RTU or DNP3 RTU over RS485 communications enable direct SCADA integration, while the 19-300 Vdc / 40-250 Vac power range and 50/60 Hz support consolidate global deployments and reduce the need for multiple variants.
The EDR-5000-2A1BB0 supports Modbus RTU and DNP3 RTU over RS485, providing broad compatibility with common SCADA, historian, and protection platforms. This reduces engineering time, allows centralized monitoring, and enables remote configuration and diagnostics to minimize downtime across feeder networks.
The relay accepts 19-300 Vdc and 40-250 Vac power, and it supports 50/60 Hz operation. This wide range simplifies sourcing for international installations and ensures compatibility with diverse electrical distributions found in industrial facilities and utility-interfaced equipment.
Eaton provides a standard warranty per policy 25-000: one year from installation or eighteen months from shipment, whichever occurs first. For compliance, reliability, and updates, consult Eaton support and refer to the specification sheet and datasheets for maintenance guidance and recommended spare parts.