Eaton EDR-5000-2A1CB0 Distribution Relay - Modbus TCP

Part Number: EDR-5000-2A1CB0
Manufacturer
Eaton
Part number
EDR-5000-2A1CB0

Quick Summary

The Eaton distribution relay EDR-5000-2A1CB0 provides feeder control and monitoring for industrial power distribution. Engineers often struggle to coordinate protection, metering, and communications while keeping wiring compact and maintenance simple. Public certification details such as CE, IP, or SIL are not listed in the spec; verify with Eaton for your region. Designed for feeder protection and metering applications, it supports Modbus TCP and DNP3 TCP/UDP over Ethernet for interoperable automation. This combination delivers faster fault isolation, centralized monitoring, and reduced field wiring—delivering meaningful business value through improved uptime and safer operations. With 8 inputs and 11 outputs, removable terminals, and a wide power range (19–300 Vdc, 40–250 Vac), it fits demanding installations and retrofit projects.

Product Information

Extended Description

EDR-5000-2A1CB0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay,5A, 1A, 40-250 Vac, 19-300 Vdc, Removable, Feeder,1 0, 1, over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz Sensitive Ground InputTrip Coil Monitor
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A1CB0
UPC
786679144695
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus TCP or DNP3 TCP/UDP over Ethernet RJ45
Current sensing inputs
1
I/O options
IRIG-B Sensitive Ground Input Trip Coil Monitor
Modbus / DNP3 RTU
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature: Eight flexible inputs and eleven outputs with removable terminals → Benefit: Simplified installation and easy field maintenance reduces commissioning time and labor costs. Application: Feeder circuits in industrial plants. The 8/11 I/O pattern supports both protection logic and metering signals, enabling compact panel designs while preserving expandability. Feature: Wide power supply range of 19-300 Vdc and 40-250 Vac with 50/60 Hz → Benefit: Single platform handles diverse mains environments, reducing inventory and risk during retrofits or expansions. Application: Retrofit projects and mixed-voltage installations in manufacturing facilities. Feature: Modbus TCP and DNP3 TCP/UDP over Ethernet RJ-45 → Benefit: Seamless integration with modern SCADA and EMS systems, minimizing wiring complexity and accelerating fault diagnosis. Application: Substation and plant-wide automation. Feature: Sensing inputs for current protection and metering with configurable phase currents (5A, 1A) → Benefit: Accurate protection and precise energy accounting improve reliability and enable closer compliance monitoring. Application: Power protection and metering at feeders. Feature: I/O options including IRIG-B sensitive ground input and Trip Coil Monitor → Benefit: Enhanced synchronization and advanced trip verification support critical safety and performance needs. Application: Critical power systems and emergency shutdown schemes. Feature: Conformal coating and semi-flush mounting with removable terminals → Benefit: Increased durability in harsh environments and faster, cleaner installations. Application: Industrial environments and panel assemblies requiring resilience. Note: Warranty is Eaton Selling Policy 25-000, one year from installation or eighteen months from shipment, whichever occurs first, underscoring the importance of scheduled maintenance and proactive replacement planning for uptime and total cost of ownership.

Get a Quick Quote for a Eaton EDR-5000-2A1CB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2A1CB0? Enquire Now

FAQs

The EDR-5000-2A1CB0 supports Modbus TCP and DNP3 TCP/UDP communications over Ethernet RJ-45, enabling seamless integration with modern SCADA, EMS, and automation systems while reducing wiring complexity and commissioning time. This interoperability is particularly valuable for feeder protection and metering applications across plant-wide networks.
The unit provides 8 inputs and 11 outputs with removable terminals for easier field wiring and maintenance. With current sensing inputs available (1 channel) and an option set including IRIG-B ground input and Trip Coil Monitor, installation can be tailored to specific feeder protection schemes and synchronization requirements, simplifying retrofits and new builds alike.
This distribution relay excels in feeder protection, metering, and power protection for industrial power distribution. It supports voltage and current protection and metering across 19-300 Vdc or 40-250 Vac supplies, making it suitable for substations, manufacturing plants, and campus power systems where reliable fault isolation and energy accounting are critical.
Public certification details such as CE, IP ratings, or SIL are not listed in the provided spec. For cross-regional compliance, verify with Eaton directly or your regional distributor to confirm certifications and suitability for your site’s regulatory requirements before deployment.
Consider semi-flush mounting and the conformal-coated circuit boards for harsh environments, along with removable terminals for rapid maintenance. Plan for the wide power range (19-300 Vdc, 40-250 Vac) to minimize power supply choices, and leverage Modbus/DNP3 for centralized monitoring to reduce on-site diagnostic visits and improve uptime.