Quick Summary
The Eaton distribution relay EDR-5000-2A1EB0 provides centralized feeder protection for industrial power circuits. Engineers often struggle to integrate protection relays into PROFIBUS networks while maintaining clear fault visibility across feeders. Certification status varies; common industry expectations include CE marking and IP or SIL considerations; confirm exact details with Eaton for your application. By combining Profibus-DP connectivity, conformal-coated boards, and flexible I/O, this relay delivers scalable protection with faster commissioning and lower lifecycle costs.
Product Information
Extended Description
EDR-5000-2A1EB0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Profibus-DP over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, over D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz , Sensitive Ground Input,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A1EB0
UPC
786679144824
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
Profibus-DP over D-SUB / RS485
Current sensing inputs
1
I/O options
Trip Coil Monitor IRIG-B Sensitive Ground Input
Phase current
5A, 1A
PROFIBUS-DP
over D-Sub / RS-485
Sensing inputs
Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Eaton Specification Sheet - EDR-5000-2A1EB0
Feature: Flexible power range and I/O. Benefit: Simplifies panel design across environments and reduces spare parts, enabling quicker retrofit of existing feeders. Application: Feeder protection and metering in mixed-voltage plant sections. Feature: Profibus-DP over D-Sub / RS-485 communication. Benefit: Streamlines PLC integration, minimizes wiring, and enables centralized monitoring and fault diagnostics. Application: Plant-wide protection schemes and networked control rooms. Feature: Conformal coated circuit boards. Benefit: Improves reliability in dusty or humid environments, reducing maintenance cycles and unplanned downtime. Application: Outdoor enclosures and harsh factory floors. Feature: Zone Selective Interlocking and current sensing inputs. Benefit: Faster fault isolation and coordinated protection, lowering downtime and energy waste. Application: Medium- to high-voltage feeder networks in manufacturing and process plants. Feature: I/O options including Trip Coil Monitor IRIG-B and Sensitive Ground Input. Benefit: Supports advanced protection schemes and robust trip signaling, enhancing safety margins. Application: Critical power distribution with stringent trip reliability. Feature: Semi-flush mounting and removable terminals. Benefit: Easy installation, simplified field wiring, and quick maintenance or replacement. Application: Retrofit projects and new panel builds with existing enclosures. Feature: Warranty and lifecycle coverage. Benefit: Clear support window reduces risk in procurement and long-term operation. Application: Enterprise-scale deployments and service contracts.
Get a Quick Quote for a Eaton EDR-5000-2A1EB0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-5000-2A1EB0?
Enquire Now
FAQs
Begin by wiring the device to the D-Sub RS-485 PROFIBUS-DP interface and ensuring the 19–300 Vdc / 40–250 Vac power supply is within range. Connect the 8 inputs and 11 outputs per your feeder protection scheme, then configure zone interlocking and sensing parameters in the controller software. Use removable terminals for easier field termination and verify network addressing to prevent conflicts.
Confirm a supply range of 19–300 Vdc or 40–250 Vac with 50/60 Hz operation and proper wiring for 8 inputs and 11 outputs. Ensure the system supports Profibus-DP over D-Sub / RS-485, as well as the Sensitive Ground Input feature. Check current protection and metering options, including phase current ratings of 5A and 1A to match your load profiles.
Yes. The EDR-5000-2A1EB0 is designed for feeder protection with configurable protection and metering capabilities, compatible with Profibus-DP networks for centralized monitoring. Its conformal coating, rugged inputs/outputs, and zone selective interlocking support fast fault isolation, making it suitable for process automation environments where reliability and quick recovery matter.
Certification details are typically provided by the manufacturer and can vary by region. Look for CE marking, IP ratings, and SIL considerations as part of safety and environmental requirements. For this Eaton model, confirm exact compliance with Eaton or your regional distributor to ensure alignment with your facility’s regulatory and safety standards.
Expected ROI comes from reduced downtime due to faster fault isolation, simplified wiring with Profibus-DP, and lower maintenance through conformal-coated boards. Maintenance considerations include periodic verification of network communications, protection settings, and inspection of removable terminals. A single unit can replace multiple discrete relays, lowering spare parts and installation costs over the system lifecycle.