Eaton distribution relay EDR-5000-2A1GB0 - Modbus RTU / DNP3

Part Number: EDR-5000-2A1GB0
Manufacturer
Eaton
Part number
EDR-5000-2A1GB0

Quick Summary

Eaton distribution relay EDR-5000-2A1GB0 provides robust feeder protection for industrial electrical networks. Engineers often struggle to coordinate protection zones while maintaining reliable remote monitoring without complex wiring. Compliance details are provided by the manufacturer, and this model includes conformal-coated circuit boards for reliability in harsh environments, a wide power-supply range (19-300 Vdc or 40-250 Vac), and flexible 8-in/11-out I/O that simplifies installation. For industry-standard approvals, check Eaton’s official documentation to confirm CE, IP, or SIL certifications applicable to your project. This combination supports fast commissioning and scalable protection strategies, while offering long-term value through predictable performance and serviceability. Its modular topology also supports future expansion as plant protection needs evolve.

Product Information

Extended Description

EDR-5000-2A1GB0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder,1 0, 1, D-Sub / RS-485,19-300Vdc, 40-250Vac, 50/60 Hz ,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A1GB0
UPC
786679142998
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
Trip Coil Monitor IRIG-B Sensitive Ground Input
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: 8 inputs and 11 outputs provide extensive I/O for complex feeder schemes, reducing wiring complexity and enabling zone protection with centralized monitoring. This translates to faster commissioning, easier maintenance, and improved system reliability in panel and substation setups. Application: feeder protection in industrial plants and electrical rooms, compatible with modern SCADA systems through RS-485 Modbus RTU or DNP3 RTU interfaces. Feature → Business Impact → Application: Modbus RTU or DNP3 RTU over D-SUB RS-485 enables seamless integration with existing control architectures, shortening integration cycles and lowering installation costs. Application: remote monitoring and control of protection schemes across distributed facilities. Feature → Business Impact → Application: wide power-supply range (19-300 Vdc, 40-250 Vac) supports multi-plant deployments with fluctuating mains, reducing the need for separate power conditioning and lowering total cost of ownership. Application: new builds and retrofits in data centers, campuses, and manufacturing floors. Feature → Business Impact → Application: conformal coating and rugged construction increase reliability in harsh environments, minimizing downtime due to moisture, dust, or temperature swings. Application: protection relays installed in outdoor or dirty indoor environments. Feature → Business Impact → Application: zone selective interlocking (1) enhances selective tripping, reducing arc flash energy and improving service continuity. Application: coordinated feeder protection in multi-mector installations. Feature → Business Impact → Application: removable terminals and semi-flush mounting simplify installation and field service, cutting commissioning time and enabling rapid retrofit. Application: panel builders and service technicians performing upgrades or expansions. Feature → Business Impact → Application: Dual-input voltage sensing supports accurate protection logic across DC and AC systems, ensuring correct operation during power quality events. Application: mixed-power facilities such as manufacturing lines with DC drives and AC distribution. Feature → Business Impact → Application: IRIG-B compatible input options and configurable I/O allow integration with time-synchronization schemes and protection schemes, improving situational awareness and coordination. Application: protective relays in mission-critical systems requiring precise timing and coordination.

Get a Quick Quote for a Eaton EDR-5000-2A1GB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2A1GB0? Enquire Now

FAQs

Begin by mounting the unit semi-flush in the control panel, then connect the D-Sub RS-485 communication lines to the Modbus RTU or DNP3 RTU interface. Attach 19-300 Vdc or 40-250 Vac power, ensuring correct polarity for DC or AC feeds. Use the removable terminals for straightforward field wiring, and verify the 8 inputs and 11 outputs align with your protection scheme. Finally, configure the protection logic and communication addresses in the field-language of your SCADA system to enable seamless data exchange.
The relay supports a wide power range: 19-300 Vdc and 40-250 Vac, with a 50/60 Hz frequency rating. It provides 5 A and 1 A contact ratings across its outputs and uses 8 inputs with 11 outputs. The communication options include Modbus RTU or DNP3 RTU over RS-485 via D-Sub connectors, making it compatible with common industrial control networks.
Yes. Designed for feeder protection, this unit supports zone selective interlocking and multiple protection and metering functions across voltage and current domains. With 8 inputs and 11 outputs, it can monitor and control feeders in 3-phase or multi-branch configurations while communicating status to SCADA via RS-485 Modbus RTU or DNP3 RTU.
Compliance details are provided by the manufacturer. The product offers conformal-coated circuit boards for reliability in harsh environments, a wide voltage range for diverse installations, and supports common industrial protocols. For formal approvals such as CE, IP ratings, or SIL certifications, consult Eaton’s official documentation or contact Eaton directly to obtain the current certification status for your region.
The unit’s modular design, removable terminals, and semi-flush mounting simplify installation and field service, reducing commissioning time and maintenance labor. The wide power range and robust communication options minimize wiring changes in retrofits, while conformal coating lowers failure risk in harsh environments, contributing to reduced downtime and improved protection reliability over the life of the installation.