Eaton EDR-5000-2A1HA1 distribution relay - 61850/DNP3
Part Number: EDR-5000-2A1HA1
Quick Summary
Eaton distribution relay provides advanced feeder protection for industrial power systems. It helps engineers overcome the complexity of integrating protective relays across multiple protocols while maintaining reliable, secure communications. In practice, buyers evaluate certifications such as SIL safety ratings, CE marking for European compliance, and IP ratings for rugged environments; confirm with the manufacturer for this model. This solution supports Ethernet-based Modbus, DNP3, and M-Bus communications and flexible I/O for fast deployment, delivering improved uptime and easier asset monitoring. In short, it combines protection, visibility, and control to drive efficiency in industrial automation networks.
Product Information
Extended Description
EDR-5000-2A1HA1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 8, 11,Feeder, over Ethernet RJ-45, 19-300Vdc, 40-250Vac, 50/60 Hz, Projection,Sensitive Ground Input
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2A1HA1
UPC
786679143155
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
1
I/O options
Sensitive Ground Input Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Voltage Protection and Metering Power Protection and Metering Current Protection and Metering
Zone selective interlocking
1
Number of inputs
8
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Introduction to Eaton's E-Series Relay, Step 1: Physical Connections
Eaton Specification Sheet - EDR-5000-2A1HA1
Multi-protocol Ethernet communications are supported, including 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45, enabling unified protection and monitoring. Business impact: reduced engineering time, fewer wiring errors, and easier remote diagnostics. Application: feeder protection in substations and industrial plants that require cross-network visibility. Wide power supply range and 50/60 Hz operation (19-300 VDC, 40-250 VAC) allow plug-and-play installation across diverse power architectures. Business impact: simplifies design choices and accelerates commissioning. Application: mixed-voltage environments and new builds where rapid deployment is essential. Eight inputs and eleven outputs with removable terminals and projection mounting deliver flexible I/O and straightforward field wiring. Business impact: smaller panel footprint and easier serviceability, lowering maintenance costs. Application: panel boards and switchgear assemblies with tight_space constraints. I/O options such as Sensitive Ground Input, Trip Coil Monitor, and IRIG-B timing enhance fault detection and time synchronization. Business impact: more accurate events, better protection coordination, and reliable data for post-event analysis. Application: critical feeder circuits in data centers and utilities. Warranty and support aligned with Eaton policy (one year from installation or 18 months from shipment) provides lifecycle assurance and access to technical resources. Business impact: predictable ownership costs and faster issue resolution. Application: long-term protection programs and asset management in manufacturing and utilities.
Get a Quick Quote for a Eaton EDR-5000-2A1HA1
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-5000-2A1HA1?
Enquire Now
FAQs
Plan for projection mounting and utilize removable terminals to simplify wiring. The unit measures about 8.05 in depth, 8.7 in height, and 9.72 in width, with a weight near 9.259 lb, aiding cabinet layout. Power it from 19-300 VDC or 40-250 VAC at 50/60 Hz, and connect through its eight inputs and eleven outputs for robust feeder protection.
The device supports 61850, M-Bus TCP, and DNP3 TCP/UDP over Ethernet RJ45, plus Modbus/DNP3 over Ethernet for flexible network integration. Optional timing and input configurations such as IRIG-B and Sensitive Ground Input enhance synchronization and fault detection, enabling seamless SCADA and protection coordination.
Yes. With eight inputs and eleven outputs, phase current options of 5A and 1A, zone selective interlocking, and wide voltage support, it is designed for reliable feeder protection in substations and complex industrial environments. Its Ethernet-based communications enable centralized monitoring and faster fault isolation across plant networks.
The product follows Eaton Selling Policy 25-000, offering one year from installation or eighteen months from shipment, whichever occurs first. Eaton provides product documentation, spare parts access, and technical support to assist with installation and ongoing maintenance in line with authorized service programs.
It integrates Ethernet-based protection with multiple protocol options (61850, M-Bus TCP, DNP3), supports 8 inputs and 11 outputs in a compact, projection-mount form, and offers timing and special I/O features like IRIG-B and Sensitive Ground Input. The combination enables faster fault clearance, easier network integration, and improved protection coordination in modern substations and plants.