Eaton EDR-5000-2B0BB0 Distribution Relay - Modbus/DNP3 RS485

Part Number: EDR-5000-2B0BB0
Manufacturer
Eaton
Part number
EDR-5000-2B0BB0

Quick Summary

Eaton distribution relay EDR-5000-2B0BB0 provides advanced feeder protection for industrial power systems. This device simplifies protective schemes across multiple feeders, reducing commissioning time and the risk of mis-wiring. Engineers often struggle with reliable SCADA integration and remote monitoring, especially in harsh environments. The model supports Modbus RTU or DNP3 RTU over RS485 and offers 16 inputs, 11 outputs, and a wide power range of 19-300 Vdc or 40-250 Vac. These features enable flexible installations, fast fault isolation, and accurate metering. Compliance details are supplied by the manufacturer, with typical expectations around CE marking and rugged enclosure options; conformal-coated boards further enhance reliability in challenging facilities. This combination delivers reliability, faster fault isolation, and lower total cost of ownership.

Product Information

Extended Description

EDR-5000-2B0BB0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11,Feeder, , over RS-485,19-300Vdc, 40-250Vac, 50/60 Hz , Trip Coil Monitor
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B0BB0
UPC
786679143889
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
Modbus RTU or DNP3 RTU over RS485
Current sensing inputs
1
I/O options
Trip Coil Monitor IRIG-B
Modbus / DNP3 RTU
over RS-485
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Voltage Protection and Metering Power Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
Feature: 16 inputs and 11 outputs enable sophisticated protection logic and zoning. Benefit: Reduces wiring complexity and improves fault discrimination, shortening downtime in large feeder networks used in manufacturing plants and data centers. Application: Ideal for multi-feeder protection schemes in industrial facilities. Feature: Modbus RTU or DNP3 RTU over RS485 for industrial communication. Benefit: Enables seamless SCADA integration, centralized control, and robust data logging across sites, improving alarm response times and operability in utilities and processing plants. Application: Remote monitoring and control in distributed power systems. Feature: Wide power supply range 19-300 Vdc and 40-250 Vac. Benefit: Supports mixed infrastructure environments, lowering inventory and retrofit costs while simplifying installation in both DC and AC control schemes. Application: Retrofit projects and new builds with diverse power rails. Feature: Zone Selective Interlocking and Trip Coil Monitor IRIG-B I/O. Benefit: Improves protection selectivity and precise coordination during faults, reducing arc-flash exposure and maintenance events. Application: Utility feeders and complex industrial feeders requiring fast, coordinated trips. Feature: Conformal coated circuit boards and removable terminals. Benefit: Enhances reliability in dirty or humid environments and simplifies field maintenance and replacement. Application: Harsh manufacturing floors, outdoors, and chemical plants. Feature: Current, voltage protection and metering with 5A/1A sensing. Benefit: Delivers accurate protection decisions and metering data for energy management and reporting. Application: Power protection and energy metering in automation facilities.

Get a Quick Quote for a Eaton EDR-5000-2B0BB0

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2B0BB0? Enquire Now

FAQs

Start by identifying the 16 input and 11 output terminals and connect the feeder and load circuits according to the Eaton wiring diagrams. Use the removable terminals for easy field installation and verify the 19-300 Vdc / 40-250 Vac power rails match your plant supply. Ensure RS485 communication lines are properly terminated for Modbus RTU or DNP3 RTU, and confirm Zone Selective Interlocking settings align with your protection strategy.
The device supports Modbus RTU or DNP3 RTU over RS485, enabling seamless SCADA integration and remote monitoring. Plan your network topology to include a master or supervisory system, configure addressing and baud rates per the protocol, and use the 16-input/11-output logic to tailor alarms and metering data to your data historian or control system.
Yes. The unit is specified for 50/60 Hz operation and supports a wide power range (19-300 Vdc, 40-250 Vac), making it compatible with both DC control circuits and traditional AC mains in industrial facilities. This flexibility helps reduce stock diversity and simplifies lifecycle management in facilities with evolving power architectures.
The product comes with Eaton's standard warranty policy (one year from installation or 18 months from shipment, whichever occurs first). Compliance specifics are supplied by the manufacturer, and users should verify CE marking or IP-related requirements with Eaton for their exact installation, enclosure, and environmental conditions.
Common use cases include feeder protection in manufacturing lines, data center power distribution, and utility-style distribution networks requiring fast fault isolation and reliable telemetry. The device’s Modbus/DNP3 interfaces and Zone Selective Interlocking help coordinate protection across multiple feeders, reducing unplanned outages and improving asset protection.