Eaton EDR-5000-2B0GA0 Distribution Relay - Modbus RTU / DNP3 RTU over RS-485
Part Number: EDR-5000-2B0GA0
Quick Summary
The Eaton distribution relay EDR-5000-2B0GA0 provides feeder protection for industrial power systems with fast fault isolation. Engineers often struggle to integrate protection relays with control systems and ensure reliable communication over Modbus RTU or DNP3 RTU. Compliance details are managed by the manufacturer, with standard operation at 50/60 Hz and a versatile power-supply range of 19-300 Vdc or 40-250 Vac. This combination supports scalable protection schemes and straightforward commissioning, reducing engineering time and risk. In addition to core protection, features like zone selective interlocking and flexible communication support modern automation architectures, delivering value through improved reliability and operating efficiency.
Product Information
Extended Description
EDR-5000-2B0GA0 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, Modbus RTU or DNP3 RTU over D-SUB / RS485, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11,Feeder, , D-Sub / RS-485, 19-300Vdc, 40-250Vac, 50/60 Hz Trip Coil Monitor
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B0GA0
UPC
786679144879
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
None
Communication
Modbus RTU or DNP3 RTU over D-SUB / RS485
Current sensing inputs
1
I/O options
IRIG-B Trip Coil Monitor
Modbus / DNP3 RTU
D-Sub / RS-485
Phase current
5A, 1A
Sensing inputs
Power Protection and Metering Current Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Semi-flush
Terminals
Removable
Voltage sensing inputs
1
E-series protective relays
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Programming an Eaton E-Series Relay, Step 3: Getting Started with the E-Series Wizard
Eaton Specification Sheet - EDR-5000-2B0GA0
16 inputs and 11 outputs with removable terminals enable flexible field wiring and straightforward installation, reducing panel real estate needs and commissioning time. Feature → Business Impact → Application: With a higher I/O count and easy wiring, system integrators can implement complex feeder protection logic while cutting setup time, ideal for retrofits and new builds in distributions substations. The device supports Modbus RTU or DNP3 RTU over D-Sub RS-485, enabling seamless integration with SCADA and HMI systems, decreasing engineering effort and escalation when addressing alarms and metering data in industrial plants. Feature → Business Impact → Application: RS-485 communications improve remote monitoring and diagnostics, delivering faster fault location and reduced MTTR across multiple feeders. Power supply range of 19-300 Vdc and 40-250 Vac, plus 50/60 Hz compatibility, provides installation versatility in mixed environments and supports single-supply designs, cutting inventory needs and enabling easy retrofits into existing plant power architectures. Feature → Business Impact → Application: Wide input ranges simplify upgrading legacy equipment and enable uniform protection schemes across diverse electrical rooms. Current sensing inputs and phase current options of 5A and 1A offer precise protection and metering, lowering nuisance trips and enabling accurate fault analysis for reliability-centered maintenance programs. Feature → Business Impact → Application: Accurate current sensing supports energy metering and protection coordination for feeders in data centers and process plants. Zone selective interlocking (ZSI) supports coordinated tripping across feeders to minimize outage impact, reducing customer downtime and improving system availability. Feature → Business Impact → Application: ZSI supports fast, selective clearing in multi-feed configurations, essential for critical production lines and safety-critical processes. IRIG-B Trip Coil Monitor as an optional I/O enhances auditability and timing accuracy, aiding compliance with high-reliability installation standards. Feature → Business Impact → Application: High-integrity timing and monitoring improve reporting and forensic analysis for incident investigations and regulatory requirements. Semi-flush mounting and removable terminals simplify installation and service in crowded panels, while the robust base model provides a flexible upgrade path without disruptive rewiring.
Get a Quick Quote for a Eaton EDR-5000-2B0GA0
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Eaton EDR-5000-2B0GA0?
Enquire Now
FAQs
The EDR-5000-2B0GA0 is designed as a distribution relay within the Eaton E-Series family, sharing common mounting, connection methods, and communication options. For a retrofit, confirm that the base relay (EDR-5000) and existing wiring harnesses align with the 16 input/11 output configuration, removable terminals, and RS-485 communication protocol (Modbus RTU or DNP3 RTU). Review the installation manual and the Eaton specification sheet to ensure pinout compatibility and to plan any needed panel modifications.
Wiring uses removable terminals for both inputs and outputs, easing field assembly. Plan for 16 discrete input signals and 11 controllable outputs, with current sensing inputs at 1 and phase current options at 5A/1A. Route power through the 19-300 Vdc / 40-250 Vac range and connect Modbus RTU or DNP3 RTU via the RS-485 D-Sub interface. Always follow the provided wiring diagrams in the official Eaton documentation to ensure correct protection logic and metering data paths.
Yes, the EDR-5000-2B0GA0 supports Modbus RTU or DNP3 RTU over RS-485 using a D-Sub connector. Communication configuration is typically set via the relay’s internal settings or the E-Series Wizard, aligning with the control system’s SCADA or HMI. Ensure proper baud rate, parity, and addressing are matched between the relay and the remote master, and verify network integrity to achieve reliable status monitoring and I/O control.
Zone selective interlocking (ZSI) coordinates protection across multiple feeders, enabling the nearest protective device to trip first while sending a trip signal to upstream relays. This minimizes the disturbance to healthy sections, reduces arc flash risk, and shortens outage time—critical in data centers, manufacturing lines, and process industries where uptime is essential.
The product carries Eaton’s standard warranty policy, offering one year from installation or eighteen months from shipment, whichever occurs first. For service, access Eaton’s technical support and ensure you retain the purchase documentation and installation date to validate warranty eligibility and obtain any firmware updates or replacement parts as needed.