Eaton EDR-5000-2B0HB1 Distribution Relay - 61850/Mbus TCP

Part Number: EDR-5000-2B0HB1
Manufacturer
Eaton
Part number
EDR-5000-2B0HB1

Quick Summary

The Eaton EDR-5000-2B0HB1 distribution relay is a robust feeder protection and metering solution for industrial power distribution in substations and switchgear installations. It addresses the common challenge of integrating multiple communications protocols across Ethernet networks by offering 61850, Mbus TCP, and DNP3 TCP/UDP over Enet RJ45. With 16 inputs and 11 outputs, plus support for 19-300 Vdc and 40-250 Vac power, it handles wide-ranging protection tasks at 50/60 Hz. The unit includes current sensing capabilities and Zone Selective Interlocking for coordinated protection. Warranty follows Eaton’s policy: one year from installation or eighteen months from shipment, whichever occurs first. Its conformal-coated circuit boards and removable terminals bolster reliability in harsh environments, reinforcing Power Protection and Metering and Voltage Protection and Metering strategies while delivering clear business value.

Product Information

Extended Description

EDR-5000-2B0HB1 Eaton: Eaton, distribution relay, EDR-5000, Distribution relay, 61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45, 5A, 1A, 40-250 Vac, 19-300 Vdc, 16, 11,Feeder over Ethernet RJ-45,19-300Vdc, 40-250Vac, 50/60 Hz, Projection,
Product Name
Eaton distribution relay
Catalog Number
EDR-5000-2B0HB1
UPC
786679143292
Product Length/Depth
8.05 in
Product Height
8.7 in
Product Width
9.72 in
Product Weight
9.259 lb
Warranty
Eaton Selling Policy 25-000, one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first.
Compliances
Contact Manufacturer
Application
Feeder
Type
Distribution relay
Product Category
Distribution relay
Analog inputs
0
Analog outputs
0
Base relay
EDR-5000
Conformal coating
Conformal Coated Circuit Boards
Communication
61850 or Mbus TCP or DNP3 TCP/UDP over Enet RJ45
Current sensing inputs
1
I/O options
Trip Coil Monitor IRIG-B
Modbus / DNP3 TCP
over Ethernet RJ-45
Phase current
5A, 1A
Sensing inputs
Current Protection and Metering Power Protection and Metering Voltage Protection and Metering
Zone selective interlocking
1
Number of inputs
16
Number of outputs
11
Power supply range
19-300Vdc, 40-250Vac
Power consumption
40-250 Vac, 19-300 Vdc
Frequency rating
50/60 Hz
Mounting method
Projection
Terminals
Removable
Voltage sensing inputs
1
Feature → Business Impact → Application: Multi-protocol Ethernet communications is designed to operate with 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet RJ45, enabling seamless data sharing and reduced field wiring. This speeds configuration, improves protection accuracy, and simplifies SCADA integration for feeder applications. Application: substations and distribution boards requiring unified data access and rapid fault isolation. Feature → Business Impact → Application: 16 inputs and 11 outputs provide flexible I/O for complex feeder logic, enabling advanced protection schemes and localized metering without external add-ons. Application: large industrial feeders needing comprehensive monitoring and control. Feature → Business Impact → Application: Wide power-supply range (19-300 Vdc, 40-250 Vac) supports both DC and AC plant rails, reducing inventory complexity and enabling seamless retrofits. Application: retrofit projects and mixed-power environments. Feature → Business Impact → Application: Phase current options of 5 A and 1 A allow tailored protection thresholds and compatibility with common protection schemes, cutting miscoordination and nuisance trips. Application: motor and feeder protection in mixed-load plants. Feature → Business Impact → Application: Projection mounting and removable terminals streamline installation and field maintenance, while conformal coating enhances reliability in harsh environments. Application: cabinets, outdoors, or corrosive environments requiring durable electronics. Feature → Business Impact → Application: Zone selective interlocking and current protection/metering capabilities deliver faster fault isolation and accurate energy accounting, supporting improved reliability metrics and outage reduction. Application: utility feeders and industrial distribution networks.

Get a Quick Quote for a Eaton EDR-5000-2B0HB1

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Eaton EDR-5000-2B0HB1? Enquire Now

FAQs

Install the EDR-5000-2B0HB1 using its projection mounting and removable terminals for straightforward rack-mount or cabinet integration. Ensure feed power within 19-300 Vdc or 40-250 Vac and connect Ethernet RJ45 for 61850, Mbus TCP, or DNP3 TCP/UDP communications. Plan for the 16 inputs and 11 outputs to align with your feeder protection scheme and any Zone Selective Interlocking requirements.
The relay supports 61850, Mbus TCP, and DNP3 TCP/UDP over Ethernet, allowing direct integration with modern substation automation, SCADA, and energy metering systems. This reduces wiring complexity, accelerates configuration, and improves data visibility for protection and monitoring across multi-vendor environments.
Yes. With 16 inputs and 11 outputs, configurable voltage sensing, and zone selective interlocking, the EDR-5000 is well-suited for feeder protection, metering, and coordinate protection tasks in substations and industrial distribution networks while supporting power protection and metering use cases.
The data indicates Compliances are to be confirmed with the manufacturer. For regulatory certifications such as CE/SIL/IP, consult Eaton or the product datasheet to verify current status and any country-specific approvals prior to deployment.
Eaton’s warranty for this model is one year from installation or eighteen months from shipment, whichever occurs first. This coverage helps reduce downtime risk and lowers total cost of ownership by protecting against early-component failures during the critical early life of the installation.